-
Product
Mass Flow Calibration
-
Allow instrument interchangeability without affecting your process and meet ISO 9001 requirements easily and efficiently with Process Instruments’ Mass Flow Calibration and Repair Services.
-
Product
Calibration Gas
-
Cambridge Sensotec supplies bespoke gas calibration kits for our O2 and SF6 gas analysers, as well our gas detection & MAP product ranges. Each kit has the appropriate calibration gases and flow regulator supplied in a convenient carry/storage case.
-
Product
Calibrating Equipment
-
Stability DC : < 0.01 %FS / 3 min, AC : < 0.02 %FS / 3 minRipple : < 0.2 %Power Supply : 230 VAC, 50 (60) HzPower Consumption : < 250 VAOperating Temperature : 5ºC to 35ºCRelative Humidity : ≤ 80 %Distortion : < 0.5 %Display : 51/2 Digit LED Digital DisplayStep adjustment of Output Signal : 100 %FS / N, 10 %FS / N,%FS / N, 0.1 %FS / N (N = 4, 5, 6, 10 and 15)Dimensions : 190mm (H) x 480mm (W) x 545mm (D)Total Weight : 22.5 kgs (approx.)
-
Product
Bulk Acoustic Wave Technology
BAW
-
Macom Technology Solutions Holdings Inc.
MACOM’s BAW product portfolio is ideal for high performance Industrial, Aerospace, Defense, and Communications applications that require critical frequency filtering. Our high-performance RF filters enable our customers manage signal integrity in the 1 to 6 GHz frequency range. Bulk Acoustic Wave Resonators consist of two metal electrodes above and below a layer of a piezoelectric material. The piezoelectric material converts an electrical signal to a mechanical signal and vice versa. The metal electrodes provide the connections to/from the piezo material. The frequency at which resonance occurs depends on the thickness of the combined metal-piezo-metal stack. Advances in thin-film piezoelectric fabrication have enabled BAW resonators to meet RF filtering challenges up to 6000 MHz using standard MEMS fabrication process. High-performance BAW resonators-based RF filters are made of piezoelectric material having high Q-factor (>3000) and high coupling coefficient. Currently, no competitive technology provides the same high performance for RF filter applications when compared to BAW resonator-based RF filter up to 6000 MHz for the same size and cost.
-
Product
Building Acoustics
-
Measurements to evaluate and improve Building Acoustics are typically made to analyze and design noise control from room to room, or from outside to inside. Noise sources such as music systems, televisions, appliances, traffic, aircraft, and manufacturing are all around us. The field of Building Acoustics evaluates and designs the materials and methods to insulate and isolate us all from these sound sources when we are at work, rest, or enjoying leisure time. The resulting data is useful for evaluating compliance with building codes and for proposing countermeasures for areas of concern. These measurements often involve creating and measuring an artificial sound source, and then measuring the resulting noise in receiver locations.
-
Product
Calibrator
-
Sanwa Electric Instrument Co., Ltd
Is an equipment used to adjust an instrument accuracy, often associated with a specific application: temperature, pressure, weight.
-
Product
Class 2 Sound Level Calibrator
SPC70
-
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
V/mA Process Calibrator
Model KM-CAL-907
-
Kusam Electrical Industries Limited
This is a source and measure type of calibrator and it gives high accuracy of 0.02% . It has dual display. 5 digits display for measure and 6 digits display for source & white LED for backlight.
-
Product
Calibration Light Sources
-
For wavelength calibration, Avantes offers a variety of sources including Argon, Mercury-Argon, Neon, Zinc, and Cadmium. All Avantes spectrometers are factory wavelength calibrated and do not require recalibration as they have fixed slits and optics. For those customers who wish to do their own calibrations, the AvaLight-CAL light sources can be used for recalibration purposes. For auto-calibration, AvaSoft-Fill provides a calibration procedure to make this easy.
-
Product
Dimensional Calibration
-
Process Instruments certifies Gage Blocks with a state-of-the-art Pratt & Whitney Gage Block Comparator. Outside and Inside Micrometers, Depth Micrometers, Height Gages, Calipers and Dial Indicators can be repaired and calibrated to manufacturers'' specs.
-
Product
Calibration services
-
Transcat Calibration Services offers the widest scope of ISO/IEC 17025 accreditation in the industries we serve. In fact, we are accredited for over 99% of our capabilities, and more than 95% of the calibrations we perform are accredited.
-
Product
Calibrators
-
Fluke offers a wide range of pressure calibration tools with precision pressure measurement from 15psi/1 bar to 10,000 psi/690 bar boasting 0.025% full-scale accuracy. Everything from simple test gauges to calibrators with built in electric test pumps. Easy to use, rugged and reliable construction and an industry best 3-year warranty. Fluke means pressure.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Acoustic Emission Preamplifier
-
The Acoustic Emission Preamplifier is a instrument designed specifically for use with acoustic emission sensors, which is used to boost the signals and filter out any noise or interference. With its advanced technical features and robust design, the QingCheng Acoustic Emission Preamplifier is the perfect choice for professionals seeking a high-performance acoustic testing solution.
-
Product
Acoustical Measurement System
MLSSA
-
MLSSA is the industry standard loudspeaker measurement system and the MLSSA Speaker Parameter Option (SPO) is the industry standard for measuring the Thiele-Small parameters of loudspeaker drivers. MLSSA and SPO both include QC (Quality Control) PASS/FAIL functions for high-speed automated production line testing of loudspeakers and drivers.
-
Product
Legendary Calibration Oscillator
LCO Series 3.5” x 2.5” x 0.6”
-
*Connectorized Package *Low Output Power Variation (±0.05 dB)*Output Power to +10 dBm Available *Optional Internal Reference
-
Product
Handheld Calibrators
-
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
Surface Calibrators
-
Electronic Development Labs, Inc.
A software-driven process for gaming mice that optimizes the sensor to a specific surface's texture, reflectivity, and weave.
-
Product
Horizontal Calibration Instruments (Lab)
THV
-
The horizontal THV instrument has been designed for calibration and certification of gauging equipment of small dimension. It allows easy and precise checking of plug gauges, ring gauges, thread plug gauges, test and dial indicators as well as measuring of high precision production parts.
-
Product
Partial Discharge Detection Calibration Device
-
Hangzhou Xihu Electronic Institute
Calibration Device of Transient Earth Voltage PD detector, calibration device of ultrasonic PD detector, calibration device of high frequency PD detector, calibration device of ultra high frequency PD detector.
-
Product
Service, Modernization, and Calibration Serivices
-
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
Product
Acoustic Emission Crack Diagnosis
-
Detect abnormality by diagnosing machine condition in real time
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
NIST Calibration for D600A-AT.
D600A-AT-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Acoustic Testing
-
Our acoustic testing experience includes acoustic qualification and evaluating sound pressure levels. We utilize microphones, pressure trans-ducers, and an acoustic intensity meter to record acoustic measurements.
-
Product
EMC Calibration
-
Trescal provides full EMC Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. EMC Calibration services can be delivered at your site or at our lab. Accreditations for our emc calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Bond Force Measurement And Calibration Systems
BFS-20
-
Based on its design and easy handling it can be used also on other brands to measure the bond force.





























