Differential Phase-Shift Keying
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 1 Channel (Single Ended) or 1 Channel (Differential)
M2P.5960-X4
Digitizer
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
Differential Probe
-
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
Product
HandyScope HS6-DIFF With SafeGround: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMG-W5
-
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
Product
Wet/Wet Differential Pressure Transmitter
647
-
Monitor differential pressure in air/liquid flow systems, HVAC automation, pneumatic systems and process control with the Series 647 Wet/Wet Differential Pressure Transmitter. Units are temperature compensated and provide a 4 to 20 mA output signal which can be interfaced with chart recorders, data loggers and computerized monitoring and control systems.
-
Product
Ethernet/LXI digitizerNETBOX 16 Bit Multi-purpose Digitizer - 125 MS/s on 20 Channels, 80 MS/s on 40 Channels, 40 Single-Ended Inputs, 20 True Differential Inputs
DN6.596-40
Digitizer
The digitizerNETBOX DN6.59x series allows recording of up to 48 synchronous channels with sampling rates of 20 MS/s up to 125 MS/s. These products offer outstanding A/D features both in resolution and speed as a remote instrument. The powerful A/D amplifier section offers 6 different input ranges, programmable offset and a software switching from single-ended (full number of input channels) to true differential (half number of input channels).
-
Product
25 GHz differential probe with ProAxial interface
DH25-PX
-
25 GHz differential probe with ProAxial interface.
-
Product
High Voltage Differential Probes
DP Series
-
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
Product
Acute High Voltage Differential Probe, 10x/100x, 25MHz, 700V
ADP1025
-
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
Differential Current Management
-
All devices from the series/products listed below can be expanded with the "dual-channel residual current detection" add-on module to enable residual current monitoring. By comparing residual current and protective conductor current measurements, you can detect stray currents in your electrical system and initiate appropriate countermeasures.
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 4 Channels (Single Ended) or 2 Channels (Differential)
M2P.5962-X4
Digitizer
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
Analog I/O module with 16 differential analog output channels
IO107
-
This I/O module is a dedicated analog output module with a resolution of 16 bits. Each of the 16 output channel has its dedicated D/A converter with an update time of 2.2µs. The output coupling of the module can either be ordered as differential or single-ended. Furthermore, several of these modules can be interconnected by trigger lines to synchronously update analog output channels among the different modules.
-
Product
HandyScope HS6-DIFF With SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMG-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
Differential Manometer
EM152
-
UEi Test & Measurement Instruments
Dual input manometer with easy-to-read display, intuitive interface and built-in magnet makes this manometer convenient to use
-
Product
Differential Pressure Transmitter
616W
-
Positive, negative and differential pressures can be measured within a full span accuracy of ±0.25 with the Series 616W Differential Pressure Transmitter. Units are enclosed in a polycarbonate case, rated NEMA 4X (IP66) and operate by sensing the pressure of air and compatible gases then sending a standard 4-20 mA output signal.
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 4 Channels (Single Ended) or 4 Channels (Differential), up to 80 MS/s on 8 Channels (Single Ended)
M2P.5968-X4
Digitizer
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
Differential Pressure Adapter w/ App Compatibility
DPA1
-
UEi Test & Measurement Instruments
The DPA1 measures positive, negative and differential pressure and is compatible with iOS® and Android™ mobile devices. Measurement units can be selected from the following scales: InH2O, mmH2O, psi, bar, mBar, kPa, InHg and mmHg. The mobile device screen will display a numeric reading. And is backed by a 1-year warranty.
-
Product
Differential Scanning Calorimeters
MicroCal DSC Range
-
The "Gold Standard" for structural stability analysis of biotherapeutics, biological macromolecules and polymers in solution. Are microcalorimeters are powerful tools which enable characterization of the thermal stability of proteins and other biomolecules, primarily for biopharmaceutical development and manufacture. They are used for general stability studies, for biosimilarity and batch-to-batch comparability assessment, and for the optimization of purification and manufacturing conditions. MicroCal PEAQ-DSC systems are simple to use, requiring little assay development, and no labelling or immobilization.
-
Product
IXBF-IXBF Differential Passthrough Cable, 1.6 Meter
134731-1R6
Switch Cable
IXBF-IXBF Differential Passthrough Cable, 1.6 Meter
-
Product
Differential Measuring Systems
-
Kaman Precision Products, Inc.
Included in our technology are proven measuring systems capable of sub-micro inch resolution. Differential measuring systems are a significant advancement in precision measurement technology. It provides exceptional resolution, repeatability, and nulling accuracy for detecting the aligned/centered position of a conductive target relative to a pair of non-contacting sensors.
-
Product
Cable Assembly, Twisted Pair, Differential Signals, 78-Pin D-Type Male to Female, 2m
A078DMR-078DFR-9A200
Cable Assembly
The A078DMR-078DFR-9A200 is a 78-Pin Male to Female D-Type Cable Assembly with twisted signal pairs suitable for differential signals and is designed to be used with Pickering's 40-200 fault insertion switch.
-
Product
Differential Quartz Crystal Microbalance
Dike
-
During an experiment to detect an affinity reaction on biological material, a molecule of interest is attached to the quartz crystal of the measurement channel, this deposition can be achieved by direct binding or by capture through another protein, the result of this process is to make the quartz sensitive to the molecule to be detected.
-
Product
HandyScope HS6-DIFF: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XM-W5
-
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
Product
High-Voltage Differential Probe, 200 MHz
N2805A
High Current Probe
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
Product
Acute High Voltage Differential Probe, 50x/500x, 100MHz, 3500V
ADP5100
-
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
Explosion Proof Differential Pressure Switch
1950
-
Model 1950 Explosion-proof Differential Pressure Switch combines the best features of the popular Dwyer Series 1900 Pressure Switch with an integral explosion-proof and weatherproof housing, making it an exceptional value for either application. It is CE, UL and CSA listed
-
Product
Fully Differential Amplifiers
-
Differential amplifiers allow the process of single-ended input to complementary differential outputs or differential inputs to differential outputs. These amplifiers feature two separate feedback loops to control the differential and common-mode output voltages. Analog Devices fully differential amplifiers are configured with a VOCM pin, which can be easily adjusted for setting output common-mode voltage. This provides a convenient solution when interfacing with analog-to-digital converters (ADCs). ADI also offers a series of differential receiver products that convert differential input signals to single ended output.
-
Product
HandyScope HS6-DIFF With SureConnect: 100 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-100XMS-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 40 MS/s on 2 Channels (Single Ended) or 2 Channels (Differential)
M2P.5931-X4
Digitizer
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 40 MS/s on 8 Channels (Single Ended) or 4 Channels (Differential)
M2P.5933-X4
Digitizer
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
IEEE802.11 Ax (2.4GHz/5GHz)+ BT5.2 M.2 2230(A-E Key), PCIE-USB
AIW-163
-
IEEE 802.11ax (2.4GHz+5GHz) + BT5.22Tx / 2RxRTL8852BE22mm x 30mm x 2.2mmM.2 2230 A-E Key0~70 degreeWi-Fi: PCIe, BT: USB