Showing results: 16 - 30 of 44 items found.
-
2553 -
Xitron Technologies Inc.
The 2503AH Analyzers measure power, voltage, and current up to 500 kHz with premier precision. Available parameters include V, A, W, Power Factor, Crest Factor, K Factor, THD, Harmonics, Phase, VA, VAR, W.Hr, Triplens, Impedance, Inrush, Mean-Peak Values, Efficiency- Loss, etc.
-
2553 -
Vitrek Corporation
The 2503AH Analyzers measure power, voltage, and current up to 500 kHz with premier precision. Available parameters include V, A, W, Power Factor, Crest Factor, K Factor, THD, Harmonics, Phase, VA, VAR, W.Hr, Triplens, Impedance, Inrush, Mean-Peak Values, Efficiency- Loss, etc.
-
Newtons4th Ltd
The N4A range of AC+DC Power Sources are available with a variety of output power ratings from 6kVA up to and above 30kVA. They are the perfect solution for general power source applications as well as IEC61000 electromagnetic compatibility standards testing, offering low THD and excellent reliability.
-
Axe Technology Corp.
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
Pulse Electronics
Pulse continues to lead the way with a broad range of components that enable twisted-pair copper high-speed services to homes and businesses. Pulse components are also used in cable modems and the consumer electronics that provide home networking services. Our high-performance transformers support home phone line and power line networks. These transformers are designed to exceed ANSI and ETSI standards, and have excellent THD performance and small footprints.
-
4016(800Vp,20Arms/200Ap) -
PRODIGIT Electronics Co, Ltd.
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
AEMC Instruments
Rugged and professional, our complete line of clamp-on meters offer full functions including: AAC, ADC, VAC, Ohms, Continuity, Frequency, Diode Test, TRMS, %THD, %DF, CF and Peak. Varying in size, our clamp-on meters provide a solution to all power quality measurement needs.
-
3282(280V,1875W / 3700VA ) -
PRODIGIT Electronics Co, Ltd.
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
AC1000A -
Laplace Instruments Ltd.
The AC1000 achieves its unique price/performance ratio by actively adjusting the incoming mains waveform to produce a clean output. Other suppliers use convertor techniques to completely recreate the output from scratch. Our solution delivers an output which achieves the required THD with the minimum of hardware and expense. It includes the ability to switch the correction in or out so that the original waveform can be observed and measured if required. Overload and thermal protection systems are built-in and produce an audible warning if activated.
-
7052PH -
ACO Pacific, Inc.
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
AMPI-530 -
Amperis sl
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
*Level display as five digits number*Display selectable between acceleration, velocity and displacement*RMS, positive, negative and unsigned peak values, instantaneous value *Rotary speed measurement with Photoelectric Reflex Switch (only VM-METER+)*Main frequency (only VM-METER+)*Measurement at rotation speed or multiples (only VM-METER+)*Sound level meter (A and C weighted) and noise dose meter (only VM-METER+)*THD (distortion) measurement (only VM-METER+)*One VM-METER license can be operated simultaneously up to four times with different settings*Offline measurement
-
STAR3 -
Elcontrol Energy Net S.r.l.
STAR 3 is a high quality 96x96mm panel energy analyser provides brilliant features at a price never reached before. The new bright red LCD display, the harmonic analysis, the wide set of measured parameters including the THD available in all the models, the multi-protocol capability of the RS485 port and the high accuracy class 0.5%, the 3 years-warranty period, allow to consider the STAR 3 the new state of art of the panel analysers market
-
CRY6125 -
Hangzhou JiGao Electroacoustical Science and Technology Co.,Ltd
CRY6125 series electro-acoustic device tester is a full-featured electro-acoustic device tester with anti-noise function. Measure the performance indicators of microphones, electret microphones (microphones), microphones, receivers, earphones, headset microphone assemblies, communication caps, speakers / speakers, buzzers and other electroacoustic devices. Such as: sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, quality factor Q, equivalent volume, audio power amplifier, etc., the measurement frequency can reach 10Hz ~ 65kHz .
-
HT9023 -
HT Italia Srl
HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems.