AC Current Clamps
wrap around conductors to measure current.
-
product
Ace Password Sniffer
Ace Password Sniffer works passively and don't generate any network traffic, therefore, it is very hard to be detected by others. And you needn't install any additional software on the target PCs or workstations. If your network is connected through switch, you can run the sniffer on the gateway or proxy server, which can get all network traffic.
-
product
AC & DC Power Source
SPS-331
Kongter Test & Measurement Co., Limited
SPS-331 Support various tests including indicating meter, digital meter, energy meter, etc. At the same time, it output 2nd ~63rd harmonics.
-
product
AC/DC Digital Clamp Meter
SK-7708
Up to 2000A AC/DC.Conductor dia, : Φ55mm max.True RMS."Power-on initialize" (auto zero adjustment).Peak hold, MAX/MIN measurements.Dust proof and water resistant.
-
product
AC Load Banks
X60C Series
Mosebach Manufacturing Company
The X60C is a small suitcase style 60 kW load bank.
-
product
AC Current Probe 100 mV/A, 60A, 11 Hz LF Bandwidth, 5MHz HF Bandwidth, 1m cable
T3RC0060-LF
AC Current Probe 100 mV/A, 60A, 11 Hz LF Bandwidth, 5MHz HF Bandwidth, 1m cable.
-
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
Clamp Meter, Auto, Average, 1 kA AC, 600 V AC, 600 V DC, 46 mm Jaw Opening Max.
72-6130
A clamp-on type test meter with AC/DC voltage and AC current measurement.
-
product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
product
Current Probe
LFR
Power Electronic Measurments Ltd
The LFR is ideal for power quality applications. It has a small, predictable phase error, for power measurements at 45/65Hz. The wide bandwidth allows accurate measurement up to and even above the 400th harmonic.
-
product
Multi-output AC Power Supplies (CV/CF)
PCR-LE2 Series
The PCR-LE2 Series are designed based on the PCR-LE Series that supports single-phase output, single-phase 3-wire output, and three-phase output within the rated capacity by selecting the switch from the front panel operation.The PCR-LE2 series offer the same basic performance, using the common power unit of the PCR-LE Series, with providing easier installation and saving the space more efficiently compare to the individual allocation of the system for a single phase, single-phase 3-wire, and three phase systems. The lineup of PCR-LE2 Series are available in 5 models:6 kVA, 9 kVA, 12kVA, 18kVA, and 27 kVA model.
-
product
Portable Eddy Current Flaw Detectors
Portable eddy current (EC) flaw detectors inspect metallic parts and perform highly reliable and advanced flaw detection of surface and near-surface defects. Olympus offers portable eddy current equipment to meet a broad range of applications, including the detection of surface or near-surface defects, and the inspection of bolt holes.
-
product
DC Leakage Current Monitor
MDLA-100
MULTI MEASURING INSTRUMENTS Co., Ltd.
This DC Leakage Current Monitor constantly observes leakage current of DC circuit like as PV generation system, etc. and lights up the warning lamp with signal output, when the leakage current exceeds the setting value.
-
product
Digital Harmonics Clamp Tester
HWT-301
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Harmonics and leakage current measurements.*Up to 25th harmonics current and voltage measurements.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Conform to IEC safety requirements.
-
product
Split type AC Current Sensor
CTF-13NF
MULTI MEASURING INSTRUMENTS Co., Ltd.
* Ultra compact size and high accuracy. * Easy installation in the distributing box. * Compliant with RoHS drective.
-
product
Current Loop 20 MA Constant Current SI-module With Optical Isolation
MXTTY
Current loop 20 mA constant current (active, passive) SI-module with optical isolation.
-
product
Regenerative AC load function
61800 Series Optional Function
The regenerative AC load function consists of various modes such as CC Rectified mode, CP Rectified mode, CR mode, CC Phase lead/lag mode and CP Phase lead/ lag mode. The Rectified Mode is capable of simulating non-linear rectified loads with characteristics similar to Chroma 63800 series AC load where the voltage and current operate at the 1st and 3rd quadrant. The Rectified Mode supports both CC and CP functions with current, power and CF as parameter settings.
-
product
Current Transformers
Excellent measurement technology requires high-quality current transformers. The product portfolio comprises a wide range of current transformers for load currents (operating currents) and residual currents (RCM). Different designs cover a variety of installation situations and metrological requirements, and enable retrofitting. AC/DC sensitive measuring current transformers use a special measurement method to detect both AC and DC currents of different frequencies.
-
product
Programmable ProBus Current Adapter
CA10
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. It allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
product
AC Power Calibrator
LS3300
The LS3300 is an AC signal generator capable of outputting both current and voltage simultaneously, thus allowing it to calibrate power meters. Providing output ranges of 10mV-1250V, and 0.3 mA to 62.5 A, and upto 78.125 kW, the unit is capable of calibrating up to 0.15 % Class Power meters. New features on the LS3300 include a high definition LCD display, a vector diagram, and the ability to synchronize up to three units to emulate anything from single phase two wire to three phase four wire systems.
-
product
TMR Current Sensors
MultiDimension Technology Co.,Ltd.
An open-close current transducer, high sensitivity and signal-to-noise ratio TMR chips are used in the design, which based on Tunneling magneto resistance effect. The transducer has a built-in temperature compensation and nonlinear compensation circuit, which can accurately measure DC, AC and pulse current. The transducer has many benefits ,such as high precision, wide bandwidth, low power consumption, excellent isolation performance and so on. Besides, the design of open-close structure makes it easier to install and unload.
-
product
Current logger0 to 20mA
TK-4802
Supplied with an input cable, this logger can measure current between 0 and 20mA DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.
-
product
DC/AC Current Probe 400A
697
Use this instrument to test starting and charging systems. It can even be used to test relative compression when used with your lab scope or graphing meter. Unit is designed for use with digital multimeters, lab scopes or graphing meters.
-
product
Resistive & Capacitive AC Load Bank
RCD
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
product
True RMS Clamp Meter w/ ATTPC3
DL389BCOMBO
UEi Test & Measurement Instruments
True RMS Dual Display Clamp Meter w/ Temperature and ATTPC3
-
product
Clamp type DC/AC Current Sensor/with Voltage Output
LAD-240
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size*With DC voltage output*DC 1A~200A
-
product
Fuse Buddy Current Loop
307M/308B
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
product
Clamp Meters
The APPA clamp meters are a workhorse tool for everyday use. These clamp meters are designed for reliable readings.
-
product
Split type AC Current Transformer
CTF-400T
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
product
Live Line Clamp Insulation Resistance Tester
MLIT-1
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy and convenient live line insulation measurements for servo motor,inverter motor and power line.・More than 0.1MΩ for power line.・More than 10MΩ for servo motor and equipment.
-
product
High Power Programmable AC Source with Transients
61510
Chroma Systems Solutions, Inc.
Power Rating:61511: 12KVA61512: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation





























