IR Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
product
Industrial Calibrators
A temperature calibrator, often called a thermometer calibrator, is used to correct inaccuracies in installed thermometers and temperature sensors, because temperature measurement is a critical parameter in many industrial processes. Although simulators are sometimes called temperature calibrators or thermometer calibrators and may be used to provide thermometer calibration for the electronics in an installed system, a temperature source with a calibrated reference sensor is still required to provide a complete and meaningful calibration. Fluke Calibration industrial and field temperature calibrators include: Metrology Wells; Field Metrology Wells; field dry-well calibrators; handheld dry block calibrators; Micro-Baths; large target infrared calibrators; field IR calibrators; ice-point dry-well; and thermocouple furnaces.
-
product
IR Calibration Instruments
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
product
Standard Products
SBIR offers an extensive line of reliable, high performance test equipment used to characterize and calibrate IR, Visible and Laser systems. Products include blackbodies, visible sources, target wheels, targets, collimators, target projectors, laser test modules/systems and IRWindows™ software for automated testing. These modular, cost effective instruments are user-friendly and easily integrated into automated test systems. For more information, including printable data sheets, select a product from the list.
-
product
Temperature Calibration
In our temperature lab we have the capability calibrate a wide range of temperature products such as catering food probes from deli to restaurant, industrial systems for manufacturing and quality checks using thermocouples surface probes or insertion probes we also calibrate IR (Infrared) thermometers.
-
product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
product
Calibration Kit YAV90MMU
YAVMMUCK
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
1 Mm Calibration Kit
85059B
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
IR Detectors
Opto Diode manufactures high performance infrared detectors with a wide variety of active area sizes, cooling alternatives, packaging, windows, lenses, and filters options. These detectors are ideal for gas analysis, emissions monitoring, spectroscopy, process control, flame and fire monitoring. Our A Series lead sulfide (PbS) detectors provide the highest sensitivity in the 1µm to 3µm wavelength region. Our B Series lead selenide (PbSe) detectors deliver the best overall performance in a wider spectral range from 1µm to 5µm. Our multichannel (MCDs) devices are ideal for simultaneous detection of multiple gases including CO2, CO, and other hydrocarbons.
-
product
IR Windows
A company''s greatest investment is not the equipment that''s behind the panel door; top priority is to offer the ultimate protection for the electricians, engineers and inspectors who risk their lives every day doing their jobs.
-
product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.





























