Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1H-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I15-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I35-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2250-9
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Intrinsically Safe Calibrators
We offer calibrators that are Intrinsically Safe and can be used in hazardous Ex areas, where explosive gases may be present. Using Ex certified calibrators makes it easier for you, as it eliminates the need for always getting hot-work permits when going on site. Our Ex calibrators are both ATEX and IECEx certified.
-
product
Capacitance Standard Set, 0.01uF To 10uF
16380C
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
Pressure Calibration
Trescal provides full Pressure Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Pressure Calibration services can be delivered at your site or at our lab. Accreditations for our pressure calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Standard Modal Analysis
EDM Modal Standard Modal Analysis provides the user with a complete arsenal of tools, from FRF data selection and parameter identification to results validation and mode shape animation.
-
product
Force Calibration
Trescal provides full Force Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Force Calibration services can be delivered at your site or at our lab. Accreditations for our force calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Temperature Calibrators
Highly accurate dry well temperature standards designed for testing and calibrating a broad range of thermometers, temperature sensors, thermocouples, RTDs and temperature switches used in military and industrial applications.
-
product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1C1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Calibration Kits
Atec’s Portable Calibration Kit, PN AHT63506-1, is used to calibrate instrumentation and transducers in engine test cells, as required per T.O. 33K6-4-3416-1 or Atec Technical Manuals.
-
product
Instrument Transformer Calibrators
CTPT 81
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
product
Standard for Mass Interconnect Performance
TITAN
TITAN sets the standard for Mass Interconnect performance, configuration modularity and long term reliability. TITAN has been designed to offer exceptional configuration flexibility for use with any ATE platform and offers unparalleled I/O density coupled with the widest selection of contact types available for Mass Interconnect.
-
product
Helmholtz Coils (Field Standards)
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
product
Hart Multifunction Calibrator
Model 26 / 26 H
Kusam Electrical Industries Limited
The multi-functional field process calibrator with high accuracy and stability, which can provide powerful measurement or output functions & other special functions to meet all the calibration work for field process control.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T135
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Cryogenic Millimeter-Wave / Microwave Test Fixtures and Calibration Kits
upj10
KEYCOM''s cryogenic millimeter-wave / microwave test fixtures and calibration kits are specifically optimized for testing the performance of patterns between the edges of printed boards(edge type) and circuit testing on the printed boards(probe type). They are also designed to minimize heat capacity by miniaturizing their dimensions so they cool off efficiently, and materials with low coefficient of linear thermal expansion such as invar are used for major parts where high dimensional stability is required. Their operating frequency ranges from DC to 110GHz.
-
product
Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL DU
The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Auto Calibration for Load & Extensiometer
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
product
Electrical Test Equipment Calibrators
The industry leading series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers.
-
product
PLTS Advanced Calibration
N19305B
PLTS N19305B extends the N19301B base product to perform advanced calibration techniques such as Automatic Fixture Removal (AFR)
-
product
Hydraulic Calibration for Load Cell
HLCS-10000
Jinan Testing Equipment IE Corporation
The Hydraulic Calibration System is specially designed for the calibration of load cells with higher capacity. The Calibration for Load Cell can calibrate the load cell within +/-1%.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
Standard Voltage 9 Pin D-Type Connectors
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Automatic Calibration Module
ACM2509
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
product
Capacitance Standard Frame
AH 1100
The AH 1100 capacitance standard frame containing from one to four AH 11A fused-silica capacitance standards provides reference capacitors of unexcelled stability. The inherent stability of this system when subjected to mechanical or thermal shock makes it the ideal transfer standard for capacitance. The built-in precision temperature controllers make it a simple, reliable system to use.
-
product
Digital Pressure Calibrators & Gauges
While the industries that use digital pressure test gauges have evolved, the need for durable, insightful, and highly functional equipment remains strong. We've built our digital pressure test gauges with environmental accuracy and performance flexibility in mind.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02