Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 100 of 100 items found.

  • Automatic Calibration Module

    ACM2509 - Copper Mountain Technologies

    ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2520 - Copper Mountain Technologies

    ACM2520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full 2-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Analog Power Supply

    Type NPS-2412 - National RF, Inc

    National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.

  • Test Engines

    Verified Systems International GMBH

    The test system cluster architecture is based on dual CPU or 4-CPU PCs acting as cluster nodes. The nodes communicate and synchronise over a high-speed network (Myrinet or InfiniBand). A modification of the Linux operating system allows to run the test execution and evaluation algorithms in hard real-time on reserved CPUs, where scheduling is non-preemptive and controlled by the test system itself. The interrupts caused by interfaces to the system under test may be relayed to CPUs designated explicitly for their handling. This approach offers the opportunity to utilise high-performance standard hardware and the services provided by the widely accepted Linux operating system in combination with all mechanisms required for hard real-time computing. The cluster architecture presents an opportunity to distribute interfaces with high data throughput on different nodes, so that PCI bus overload can be avoided. In addition, the CPU load can be balanced by allocating test data generators, environment simulations and checkers for the behaviour of the system under test ("test oracles") on dedicated CPUs.

  • ARINC 664 Simulator & Analyzer Applications Software

    F-SIM-A664 - Avionics Interface Technologies

    Software GUI Application for Operating AIT ARINC 664 Interfaces - Simulate Multiple ARINC 664 End Systems Simultaneously - Full definition of input/output VLs, input/output Sampling and Queuing message ports, & TFTP Clients & Servers - Capture & Analyze Data from Multiple Virtual Links (VLs) - Live display showing all of the detected ARINC 664 VLs and message counts - Live displays showing all of the detected source and destination message (UDP) ports - Record network data to PCAPNG for use with Wireshark - Replay Previously Captured Bus Data - Also Supports MIL-STD-1553, ARINC 429 & Data Load operations

  • Bench-Top & Shop Loader Solutions

    Avionics Interface Technologies

    To satisfy ARINC 615/615A data loader requirements in system engineering labs, avionics system manufacturing, and maintenance depot applications, AIT provides data loader software that can be used together with AIT’s full line of ARINC 429, ARINC 664, and Ethernet interface modules and integrated into a variety of host desktop PC systems and ATE environments. The F-SIM-LDR-615 software provides ARINC 615-3/4 data loader support and is compatible with all of AIT’s ARINC 429 interface modules. The F-SIM-LDR-615A software application provides ARINC 615A-1 /2/3 data loader support over Ethernet and ARINC 664 networks and is compatible with all of AIT’s ARINC 664/Ethernet interfaces modules. The F-SIM-LDR-615 and F-SIM-LDR-615A software products include both graphical user interface (GUI ) data loader applications and command line data loaders which are scriptable and can be called from shell scripts, batch files, and python for support of automated load operations.

  • ±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester

    HBM-S1-B - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm

  • Automatic Meter Reading Unit

    Signals & Systems India Private Limited

    SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • ±6 kV ANSI/ESDA/JEDEC HBM Test System

    HBM-TS10-A - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C

Get Help