Showing results: 76 - 90 of 161 items found.
-
ST-2000 Cos∮ -
Standard Electric Works Co., Ltd
● Principle : Phase angle sensing transducer● Rated Accuracy : ±3% phase angle● Scale : Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 Lag Power Angle: Lead 90° – 0° – 90° Lag● Effective Power Factor Measuring Range : Lead 0.5 – 1.0 – 0.5 Lag● Scale Length : Approx. 135mm(5-3/8”)● Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
-
QPADL3 -
GigaBaudics Co.
The QPADL3 is a programmable delay line instrument with 4 independent channels designed for adjusting the time delay or phase of radio, microwave or even digital signals with bandwidths from DC to 3 GHz.
-
MCL-4000F -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*3CT method enabled easy AC leakage current measurements with simple clamping of each phase conductor by 3 CTs or 4 CTs.*Use 4 CTs for 3phase/4wire power system.*Load current measurements for each phase conductor up to AC 800A.*Filter rejection for high frequency noise.*DC mV output for recorder.
-
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
Teledyne Lincoln Microwave
Four port devices can be realized by joining two 3 port devices via the appropriate ports. As system performance requirements become more demanding, new design approaches must be adopted. These include Faraday rotation devices and phase shift circulators. The bandwidth and isolation limitations of 3 port devices are overcome through a distributed architecture that enables more ferrite material to be incorporated into the transmission path, thereby achieving an increase in the biasing magnetic field. Phase shift circulators can be designed to handle higher RF power than 3-port devices.
-
PM7000 -
Outram Research Ltd (ORL)
It offers virtually everything needed to monitor and record power for surveys and audits. It includes 4 voltage input channels capable for measuring 0 to 600 Vac and 4 current input channels for use with voltage output current clamps, or Rogowski Coil sensors supplied. Twelve pre-stored connection configurations are set for 3 phase, 2 phase and single phase measurements. Users can also configure their own set-up and math calculation requirements and save them to non-volatile memory.
-
400XAC Series -
EEC
Our 400XAC Series AC Power Sources provides both 1Ø and 3Ø AC or DC power in a single box solution. If you need an AC Power Source with superior application flexibility, look no further than the EEC 400XAC. Ideal for both production and laboratory use, this 3 phase AC Power Source provides a unique feature set at a competitive price point. Our exclusive SmartCONFIG feature allows the 400XAC Series to switch from 1 phase to 3 phase power with the push of a button. This flexibility maximizes your investment while providing you the AC and DC power that your application needs. The 400XAC Series AC Power Source includes the following models: 430XAC and 460XAC.
-
PC15250 -
Martindale Electric Co. Ltd
Quickly and simply prove continuity of all 3 lines. Identifies which are faulty and shows the sequence of phase rotation. Fast & effective method of identifying worn or unmarked cables, and ensuring 3-phase outlets and machinery are wired correctly.
-
POLB HD 7% -
Lifasa - International Capacitors, SA
They are self-regenerating condensers with low loss polypropylene dielectric, filled with N2 inert gas mainly, or with resin, and with overpressure disconnection system, which offers a high level of safety against defects, when cutting the 3 phases in case of action.
-
Part No. SHP24N50R -
Teledyne Defense Electronics Relays & Coax Switch
The Series SHP phase-angle controller provides analog switching. It features an internal microcontroller and overvoltage protection. Choose relays with either removable input spring connectors or IP20 touch-proof flaps. The relays are designed in conformity with EN60947-4-3 (IEC947-4-3)and EN60950/VDE0805 (Reinforced Insulation), and feature Phase Angle switching.Available options include:SHP24N50R 50A, 9-280Vac, 600Vpeak Load; 4-20mA Control
-
CM3-VA7 -
Chuan Sheng Electronics Co., Ltd.
CM3-VA7 is a multifunctional 3-phase voltage/ current meter.With 3 phase voltage or current display at the same, configurable display range via front buttons, anti-inference design, reliable quality and easy to use and install CM3-VA7 also has multiple I/O functions including 3 relay outputs, an analogue output and a RS485 communication port running the Modbus RTU Protocol.
-
CM3-VA9 -
Chuan Sheng Electronics Co., Ltd.
CM3-VA9 is a multifunctional 3-phase voltage/ current meter.With 3 phase voltage or current display at the same, configurable display range via front buttons, anti-inference design, reliable quality and easy to use and install, CM3-VA9 also has multiple I/O functions including 6relay outputs, 3 analogue output and a RS485 communication port running the Modbus RTU Protocol
-
Aidiga Ltd.
Channels count - 1 (mono)Generated signals count - 1, 2, 3, 4Vertical resolution - 16 bitMax frequency - 22050 HzModulation - AM, FMModulation signal source - internal, LineInSingle Phase shift - YESDAC - Audio cardData recording - NO
-
HSX SERIES -
Holzworth Instrumentation, Inc.
The HSX Series are broadband frequency sources exhibit industry leading phase noise and spectral purity performance coupled with a highly accurate dynamic range of up to +20dBm and down to -110dBm. The 1U high form factor offers 1, 2, 3 or 4 channel models; all providing the ultimate in frequency accuracy, while the phase coherent RF outputs provide the ultimate in channel-to-channel stability.
-
1811 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).