Temperature Calibration Baths
-
product
Calibration Baths
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
product
Temperature Module
U1586B
The U1586B temperature adapter expands the capabilites of your handheld oscilloscope or handheld digital multimeter to measure temperature, either in °C of °F. To be used with a K-type bead thermocouple, and with approximately 1600 hours battery life with an alkaline battery, this adapter ensures you get the most out of your handheld scope or DMM purchase.
-
product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
1 Mm Calibration Kit
85059B
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
product
sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
780877-01
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
785043-01
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O
784750-01
4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.
-
product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
USB Temperature Measurement Bundle
The USB Temperature Measurement Bundle includes a CompactDAQ Chassis with the C Series Temperature Input Module for temperature measurements. The USB Temperature Measurement provides a portable, USB-based sensor measurement system with features such as anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
product
Linear Measurement Kit
55280A
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
product
Calibration Kit YAV90MMU
YAVMMUCK
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).





























