  • Multi-Purpose Digital H. V. Phasing Meter

    MDP-50K - Standard Electric Works Co., Ltd

    ● AC 50kV and DC 50kV measurement with direct reading.● 4000-count LCD.● Input impedance : 400 Mohm● Auto-ranging : AC : 4.000kV / 40.00kV / 50.0kV DC : 4.000kV / 40.00kV / 50.0kV● MDP-50K must be connected with an approved hot stick, such as HS-175, HS-120.● Polarity indication : Positive / Negative● Backlight function.● Auto power off.● Power source : 1.5V(AA) alkaline battery × 2.● Low battery indication(Multi-level). ● Protection class : IP66

  • Watt-MuncherPortable Load Bank

    Simplex Inc

    The Simplex Watt-Muncher is a small DC rated load bank used to test battery systems, AC to DC rectifiers and power supplies, battery chargers, UPS systems and DC generators. The Watt-Muncher provides a variable test load used to measure charge and discharge rates, response, stability and endurance. Corresponding calibrations and adjustments can be made while maintaining a constant, precise, resistive load on the power source.

  • Protection Test Set

    COMPANO 100 - OMICRON electronics

    COMPANO 100 is the universal and easy-to-use solution for all types of basic testing duties in electrical energy systems. Controlled electronic sources allow the user to obtain exactly the desired value and to output signals with variable frequencies and other signal forms, automated ramps, and pure DC.

  • Fiber Optic Transmission Systems

    B-1020-B - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation has developed a HV compact analog fiber optic transmitting and receiving system, with optional over-voltage limiting, designed to drive instrumentation from a DC to 1MHz signal source. The system is available with optional multiple input and output ranges of ±0-1V PK, 0-5V PK to 0-10V PK. It will also operate in conjunction with Ross Engineering Corporation’s high accuracy high voltage wideband voltage dividers, which are useful from DC to over 10MHz up to 1,000,000V PK at 0.01% to 3% accuracy. Transmitters and receivers can be powered by either AC or DC.

  • THREE PHASE SECONDARY CURRENT INJECTION TEST SET

    TEST-330B - Beijing GFUVE Electronics Co.,Ltd.

    Three phase secondary current injection test set is testing relay set, protective device, instruments, output ac dc current and voltage source, embedded Window XP system.

  • Multi - Purpose Digital High Voltage Phasing Meter

    Model KM-MPS-50K - Kusam Electrical Industries Limited

    • AC 50kV and DC 50kV measurement with direct reading.• 4000-count LCD.• Input impedance : 400 Mohm• Auto-ranging : AC : 4.000kV / 40.00kV / 50.0kV, DC : 4.000kV / 40.00kV / 50.0kV• KM 50K must be connected with an approved hot stick (Optional).• Check phases are "in-phase" or "out of phase".• Polarity indication : Positive / Negative• Backlight function.• Auto power off.• Power source : 1.5V(AA) alkaline battery × 2.• Low battery indication(Multi-level).

  • Cable Fault Testers

    Greenlee Tools

    *Compact and lightweight solution for underground cable testing*DC Hi-Pot test of de-energized, shielded underground primary cable*No external power required - self-contained 8kVDC voltage source*Can be used up to a distance of 1500 ft (457m)*Clear and simple test results - analog bar graph and indication of good or faulted cable*Safety feature - measures AC voltage before converting to a DC voltage tester*Lightweight, single hot stick operation for testing cable

  • Dual Precision Power Amplifier

    VX4616 - VX Instruments GmbH

    2 galvanically isolated bipolar output channelsFrequency bandwidth up to 150 kHzOutputs are operating as inverting precision power amplifierOutputs are operating as programmable DC source (voltage or current)Outputs are programmable or adjustable via an external analog sourceAuto sensing featurePulse modulation with extremely high slew rate

  • Transconductance Amplifier

    1620A - Ballentine Laboratories, Inc.

    The 1620A provides high accuracy current levels from dc to over 10 kHz for calibrating ammeters, current transformers and shunts. It also provides output current up to 100 Amperes and as such may also be used as a high accuracy power supply, and as a power source in welding and bonding applications.

  • Photovoltaic Array Simulator, 15 kW, 1500 VDC

    N8900APV Series - Keysight Technologies

    The PV simulators are autoranging, programmable DC power sources that simulate the output characteristics of a photovoltaic array under different environmental conditions (temperature, irradiance, age, cell technology, etc.) enabling you to quickly and comprehensively test inverter MPPT algorithms and inverter efficiency. The DG8900 SAS control software creates and downloads solar I-V curves to a single output solution. For multiple outputs choose the DG9000 SAS control software which can be used with up to 12 N8900APV sources.

  • Business Machines

    Haydon Kerk Pittman

    Innovation in 3D Printing, Automated Lighting, Mobile Communications, Commercial Printing and other industries is driving demand for linear actuators, lead screws and rails as well as DC motors. Haydon Kerk Pittman’s diverse product range and technology often makes it the preferred single source supplier of components or custom sub-systems. Whether you choose stepper, DC brushed or brushless technology as part of your rotary or linear mechanism, Haydon Kerk Pittman can provide the optimum solution.

  • Preamplifiers

    A.H.Systems, Inc.

    A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.

  •  Impedance Analysis For E5061B-3L5 LF-RF Network Analyzer

    E5007A - Keysight Technologies

    The E5007A provides the impedance analysis (ZA) firmware for the E5061B LF-RF network analyzer. This option enables the analyzer to measure impedance parameters of electronic components such as capacitors, inductors, and resonators. The combination of NA and ZA capabilities further enhances the analyzer’s versatility as a general R&D tool. Basic ZA functionalities including fixture compensation and equivalent circuit analysis are supported by the firmware. The DC biased impedance measurement is possible with the built-in DC bias source provided by the E5061B-3L3/3L4/3L51.

  • DC Bias Current Power Supply

    TH1775 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.

  • IR Emitters and Controllers

    Opto Diode

    Opto Diode manufactures five families of infrared emitters that are used for a variety of medical and industrial applications, including gas analysis, environmental monitoring, spectroscopy, and process control. From the steady state (DC) emitters (SA Series), to high-power steady state emitters (SHA Series), to pulsable sources of black-body radiation (SVF Series) and fast pulsable sources of black-body radiation (SPF Series), to high-speed IR emitters with integrated drive electronics (PIREPLUS), we have the perfect family of products for your critical requirements.