Showing results: 646 - 660 of 1446 items found.
-
HSR40 CC -
Curtiss-Wright Defense Solutions
Curtiss-Wright’s CHAMP-XD2 digital signal processor (DSP) card handles the incoming data and features two multi-core Xeon D processors and two built-in 40 GbE interfaces. The processor hosts a Linux operating system and runs the HSR40 data recording and storing application. The processors can easily absorb the incoming data and redirect it to the persistent storage media, using 3rd generation PCI Express (PCIe), enabling the efficient movement of all the data.
-
Gamma Scientific Inc.
LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.
-
ET Power Systems Ltd.
Electronic test engineers use a variety of precision instruments for R&D, vendor verification, and production testing. ETPS can supply a number of general test instruments that can be used in stand alone mode or automated for high throughput testing. Dedicated battery test systems with automatic charge and discharge modes with data logging are available. The standard 16 and 32 channel systems have range up to 5VDC ensuring their suitability for a wide variety of cells.
-
Quality Engineering Associates Inc.
Drawing on years of applications experience, QEA has developed a comprehensive line of tools for evaluating EP printer components and sub-systems. This unique family of test systems embodies innovative engineering solutions and a fundamental understanding of the physics of EP processes to give you “must-have” tools for high-speed printer R&D and quality control. These non-contact, non-destructive tools emulate the EP printing process and deliver quantitative data you can rely on. QEA tools are ideal for:
-
3550 -
TEGAM Inc.
The Model 3550 Programmable Impedance/LCR Meter tests within the extensive frequency range of 42.0 Hz to 5.00 MHz. It measures L, C, R, |Z|, Y, D, Q, R, Phase, G, X, B, V, I, F, in series or parallel modes. With a basic accuracy of 0.10%, the 3550 is designed for a wide variety of automated or manual test applications. RS-232C & I/O interfaces are standard; GPIB or BCD interfaces are optional.
-
N6700 Series -
Keysight Technologies
The N6705A is 4-slot mainframe that accepts 1 to 4 modules in any combination. Modules are ordered separately. Maximum output power is 600W. The DC Power Analyzer is designed for bench testing in R&D. It is a highly integrated instrument that combines up to four advanced DC power supplies, DMM, oscilloscope, arbitrary waveform generator and datalogger. It provides an easy-to-use interface, with all sourcing and measuring functions available from the front panel.
-
785188-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
782615-02 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
782615-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at … the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
288 SVD -
Standard Electric Works Co., Ltd
● AC Voltage detection: 240V ~ 50kV ● Waterproof● Easy-to-wear on body or belt ● Ultra-bright LED indication● High pitch sound indication● Self-test & diagnostic circuitry● Friendly priority alert reporting● High impact type casing● Different alerting sound & light● Meets EN 61326-1● Dimension : 114(L) × 67(W) × 27(D) mm● Weight : Approx. 152g (battery included)● Power supply : 9V(6F22) × 1
-
LS3081D -
Tabor Electronics Ltd.
The LS3081D, 3GHz Single Channel RF Analog Signal Generator, offers industry leading performance, combined with a compact small footprint form factor. The LS3081D features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The LS3081D was designed to offer excellent performance and abilities combined with an affordable price tag, needed from the R&D benches to the production lines.
-
M9290A -
Keysight Technologies
Deploy a smaller microwave footprint, no trade-off in precision: Rely on fully specified performance up to 26.5 GHz in 4 slots Optimize your balance between speed, sensitivity and accuracy with the choice to operate in swept or FFT modes Perform fast calibrated stimulus response measurement with full-band tracking generator Smooth the transition between R&D, manufacturing, and maintenance: CXA-m is code compatible with benchtop X-Series signal analyzers and ESA spectrum analyzers
-
GX3216 Series -
Marvin Test Solutions, Inc.
The GX3216 is a multi-channel analog input and output cPCI module, supporting 16 differential input channels and two analog output channels. Dedicated 1 MS/s D to As and A to Ds allow simultaneous acquisition and generation of analog signals. Input ranges are software-selectable as ±10 V, ±5 V or ±2.5 V. The inputs are divided into two channel groups, with an independent software-controlled range assignable to each group. Two analog output channels provide software-selected output ranges of ±2.5 V, ±5 V or ±10 V and independent of the input range assignments. Output data is provided via two dedicated control registers, or through a 256 K-Sample FIFO buffer for waveform generation. Six bidirectional digital I/O lines are also available and can be programmed as inputs or outputs.
-
TAGARNO A/S
TAGARNO digital microscopes give you unique and easy to use magnification equipment to use in a variety of quality control processes as well as R&D efforts or in your repair and rework in an endless range of segments. The digital microscopy camera technology enables you to see any small object in ultra sharp magnification and to document your work with just a single click. It also allows multiple viewers at the same time and thereby greatly improves collaboration.
-
HATS -
Brüel & Kjær Sound & Vibration A/S
Designed for realistic in situ electroacoustics tests on, for example, smartphones, headsets, audio conference devices, microphones, headphones, hearing aids and hearing protectors. High-frequency Head and Torso Simulator (HATS) Types 5128-C and -D are manikins with built-in realistic ear and mouth simulators that provide a realistic reproduction of the acoustic properties of an average adult human head and torso. High-frequency HATS is designed for in situ electroacoustics tests and can cover the full audible frequency range (up to 20 kHz).