High-Density 128-CH Isolated DIO/DI/DO PCI Cards
PCI-7442/7443/7444
-
Responding to the industry"s need for high-density digital input/output modules, the ADLINK PCI-7442/7443/7444 DIO card series delivers up to 128 opto-isolated channels for a wide range of demanding PCI-based applications. The PCI-7442/7443/7444 series comes with 64 (PCI-7442) or 128 (PCI-7443) opto-isolated digital inputs and 64 (PCI-7442) or 128 (PCI-7444) opto-isolated digital outputs. With a 1250 VRMS (excluding cables) channel-to-system isolation protection, these cards are shielded from damage caused by accidental contact with external voltage while promoting simple ground connections. All input channels are identical non-polarity with each line isolated and suited to collect digital inputs even at high-noise environments. Featuring a Change-of-State (COS) interrupt function, the PCI-7442/PCI-7443 instantly generates an interrupt request to the PCI controller when it detects a sharp change in the logical state of any of its digital inputs.
-
Product
FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ
786374-01
-
The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11601 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11601 is ideal for test cell and outdoor environments.
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-02
-
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
NI-9246, 50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module
783920-01
-
50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9246 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
Product
FD-11614, 16-Channel Temperature Input Device for FieldDAQ
785854-01
-
The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
PXIe 64-Channel Digital Output Module
42-412A-021
-
The 40-412A-021 (PXI) and 42-412A-021 (PXIe) are 64-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-02
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
NI-9202, ±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module
784399-01
-
±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module - The NI-9202 has excellent flexibility to meet the needs of your applications. The module has 16 simultaneous sampling, differential input channels to create large, distributed systems in a rugged form factor. It also has configurable filters to eliminate noise in your system while maintaining low-latency to be used in control systems.
-
Product
PXI 64-Channel Digital Output Module
40-412A-021
-
The 40-412A-021 (PXI) and 42-412A-021 (PXIe) are 64-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
Product
C Series Voltage And Current Input Module
-
The C Series Voltage and Current Input Module features up to 16 input channels with built-in noise rejection. You can use this module to combine the two most common inputs to reduce the overall number of modules you need in your measurement system.The C Series Voltage and Current Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-02
-
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
NI-9361, 32-Bit, 8-Channel C Series Counter Input Module
783407-01
-
32-Bit, 8-Channel C Series Counter Input Module - The NI‑9361 is a differential or single-ended input module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal switchable 1 kΩ pull‑up resistor. The NI‑9361 counters can perform encoder position and velocity measurements. You can synchronize the counters with other analog, digital, and counter measurements in your chassis.
-
Product
NI-9224, ±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783862-01
-
±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9224 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9224 is simultaneous sampling with two options for filtering a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
-
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
-
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
PXIe-4464 , 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-01
-
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-02
-
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
NI-9252 , ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module
786782-01
-
±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module - The NI-9252 is an 8-channel analog input module for CompactDAQ and CompactRIO systems. Each channel provides a ±10 V measurement range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9252 features a … number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
USB-TC01, 1-Channel Temperature Input Device
781314-01
-
The USB‑TC01 is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take … temperature measurements with your PC. You can connect the USB‑TC01 to any USB port to use your PC as a display and monitor data in real time. The USB‑TC01 is compatible with J, K, R, S, T, N, E, and B thermocouples.
-
Product
Transcoding Card
VEGA-3310
-
2-ch 4Kp60 or 8-ch real-time 4:2:2 10bit HEVC,AVC & MPEG-2 encode, decode & transcodeUltra-low latency supportLess than 35W power consumptionSimple-to-use API and example code for FFmpeg and GStreamer multimedia frameworks
-
Product
NI-9207, 500 S/s, 16-Channel C Series Voltage and Current Input Module
785040-01
-
500 S/s, 16-Channel C Series Voltage and Current Input Module - The NI‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection.
-
Product
NI-9228 , ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-02
-
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
PXI-6704, 16-Bit, 32-Channel, Static PXI Analog Output Module
777796-01
-
16-Bit, 32-Channel, Static PXI Analog Output Module—The PXI‑6704 is a static analog output device. You can use the PXI‑6704 to create software-timed voltage and current output applications. You can independently set the output voltage range on each channel. The PXI‑6704 also includes eight 5 V TTL/CMOS digital I/O lines.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
-
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
PXI Strain/Bridge Input Module
-
PXI Strain/Bridge Input Modules feature up to eightchannels that support quarter-, half-, or full-bridge sensors at speeds up to 102.4kS/s. The modules provide increased accuracy, high data throughput, and a range of synchronization features. Optional features include remote sensing, internal bridge completion, and shunt calibration options per channel. PXI Strain/Bridge Input Modules are ideal for dynamic strain, load and pressure measurements, and test cell installations requiring accuracy and flexibility.
-
Product
sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780875-01
-
Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.
-
Product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
-
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
Product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781209-01
-
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
785043-01
-
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
C Series Strain/Bridge Input Module
-
The C Series Strain/Bridge Input Module works with higher-channel-count, dynamic strain measurement systems. Modules can acquire measurements from up to eight channels, with compatibility options for quarter-, half-, and full-bridge sensors. The C Series Strain/Bridge Input Module is ideal for application channels requiring measurements at particular times, such as impact tests. It includes built-in voltage excitation, as well as transient isolation for high-common-mode noise rejection and improved safety.The C Series Strain/Bridge Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.