Resonance
-
Product
Generator/Analyzer for NFC/EMVCo Manufacturing Test
Micropross MP500 PT1-NFC
-
Support for ISO 14443 A/B, ISO 15693, MIFARE™, FeliCa™. Measurement correlation with NFC Forum and EMVCo certification test bench. Automated test executive with ready-to-run test sequences. Reader/Writer and Card Emulation modes, resonance frequency measurements supported on same antenna. Embedded analog measurements - LMA, field strength, S11, Q factor, waveform characteristics. Physical parameter/waveshape characteristic definition
-
Product
Electromagnets
-
The Lake Shore electromagnets (EM-V Series) produce magnetic fields with a variety of indexed air gap and pole cap configurations. The EM-V Series is ideally suited for integration into customer-designed magnetic test platforms for applications including magneto-optical studies, magnetic hysteresis studies, in-line annealing, Hall effect studies, susceptibility measurements, spin magnetic resonance demonstrations, and biological studies.
-
Product
Phase Locked Oscillators
-
Phase locked oscillators (PLO) utilize state-of-the-art planar circuits, three-terminal devices and dielectric resonator technology to generate high-quality microwave signals at lower frequencies. Frequency multipliers, amplifiers and filters are used to extend the low frequencies for higher frequency requirements. The standard offering covers the frequency range of 2 to 110 GHz and provides both internal and external reference options. The frequency stability and phase noise are dependent on the oscillator reference type.
-
Product
Antenna Analyzer
-
Measuring antenna SWR ratio with graphic display in a selected frequency range.Measuring antenna Impedance ( Z = R + j X )Measuring antenna resistance RMeasuring antenna reactance X, all the above with graphic display in a selected frequency range.Quick search for antenna resonance frequencyVery suitable for antenna measurement and adjustment.Portable and small size.Easy and intuitive operation
-
Product
Quasi Square Wave Constant Voltage Transformers
-
Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.
-
Product
Signal Integrity Measurement Systems
-
GigaTest Labs is a Keysight Technologies Solutions Partner, offering fully configured signal integrity measurement systems for high bandwidth signal integrity characterization. Our wealth of experience with Keysight's Vector Network Analyzer and Time Domain Resonance Oscilloscope tools will help you navigate and understand different instrument capabilities & configuration options that will benefit your engineering team.
-
Product
VCOs with Output Dividers
-
Analog Devices offers a range of GaAs inGaP heterojunction bipolar transistor (HBT) MMIC VCOs with output divider options to meet your application and design needs. Members of this product line integrate resonators, negative resistance devices, and varactor diodes, while featuring excellent phase noise performance.
-
Product
Highly Sensitive Magnetization Switching Evaluation system
FMSS
-
The necessity of evaluation for media by thin film and high speed magnetic recording increases as high density of magnetic recording media. This equipment is newly-developed one which applies any time-range and pulse magnetic field to test sample, and detect magnetization after applied with highly sensitive resonating sample magnetometer.
-
Product
Shallow Water Multibeam Echosounders
-
Shallow Water Multibeam Echosounders by Teledyne Marine RESON
-
Product
Signal Processors
-
Designed to handle frequencies ranging from 20Hz to 20KHz. This cutting-edge unit is specifically crafted for a wide array of applications, including room resonance reduction, anti-feedback control, special effects creation, and room equalization.
-
Product
Model And Resonance Testing
-
Response Dynamics Vibration Engineering, Inc.
Resonance identification, dynamic testing, modal analysis and operating deflection shape analysis, form the basis of our set of expertise in vibration analysis, and are described on this page, in the embedded video below, and in the links above in more detail. This is the heart of vibration testing and key to making a confounding vibration issues understandable. Our vibration testing, structural dynamics and modal analysis consulting services have helped push the limits of technologies and cutting edge designs for over 30 years.
-
Product
Resonance Dip Meter
NRM-2
-
National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.
-
Product
Hydraulic Vibration Shaker
KRD70 series
-
KRD70 series hydraulic vibration shaker converts the energy of high-pressure liquid into the power of the reciprocating motion of the cylinder through the electro-hydraulic servo valve. Especially suitable for vibration tests requiring low frequency and high force. It can realize sine, random, multi-point excitation and shock test (sine, random, sine on random, random on random, or resonant search & dwell). It’s applied for reproducing the vibrations of transportation vehicles, bulk packaging products, machinery, electrical and electronic products in the actual environment, thereby optimizing the product structure and saving costs.
-
Product
High Frequency Electromagnetic Software
Sonnet Suites
-
The Sonnet® Suites™ develop precise RF models (S-, Y-, Z-parameters or extracted SPICE model) for planar circuits and antennas. The software requires a physical description of your circuit (arbitrary layout and material properties for metal and dielectrics), and employs a rigorous Method-of-Moments EM analysis based on Maxwell's equations that includes all parasitic, cross-coupling, enclosure and package resonance effects.
-
Product
Electro-Optic Modulators
-
Thorlabs’ selection of electro-optic (EO) modulators includes free-space and fiber-coupled LiNbO3 modulators. Free-space amplitude, phase, or resonant modulators can operate at speeds up to 100 MHz. We also offer liquid crystal EO modulators for speeds up to 2.5 kHz. Fiber-coupled intensity, phase, or IQ modulators for speeds up to 40 GHz can be driven by our EO modulator drivers. A modulator bias controller is also available for use with fiber-coupled intensity modulators.
-
Product
In-Line Charge Amplifiers
-
The in-line charge amplifier is used to excite structures or machinery with a definable impulse force. Resonances are identified by impulse, an important measurement parameter for the study of dynamic behavior. The 4705A1 is a fast turn on time, 50 mV/pc, in line charge amplifier with BNC jack connectors on each side.
-
Product
Power Transformers
-
Power Transformers are used to convert voltages and isolate signals for functionality and safety. Our broad line of catalog and custom solutions range from mW to 5-10kW and are used in multiple topologies including flyback, forward, push-pull, resonant, LLC and phase shifted full bridges. Typical operating frequencies are between 80-500kHz but solutions can be adapted for greater than 1MHz operation.
-
Product
Singlebeam Echosounders & Transducers
-
Singlebeam Echosounders & Transducers by Teledyne Marine RESON
-
Product
Ultra-High Resolution Spectrometers
-
Fabry-Pérot interferometers are optical resonators used for high-resolution spectroscopy. They use the phenomenon of multiple-beam interference that results when light shines through a cavity bounded by two reflective parallel surfaces. When the light hits one of the surfaces, some is transmitted out, and the remaining part is reflected back. Fabry-Pérot produces a circular fringe pattern, similar to the Michelson pattern. However, the fringes are thinning, brighter, and more widely spaced. As a result, these instruments are able to detect and resolve the fine features of a transmission spectrum with high precision.
-
Product
AC Test Transformer
-
Shanghai Guantu Technology Co., Ltd.
How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.
-
Product
Pulsed And CW ESR/EPR: Quasi-continuous Powerful Millimeter (mm-wave) And Sub-millimeter (sub-mm Wave) Orotron Generator
-
Insight Product Company offers Quasi-continuous powerful millimeter (mm-wave) and sub-millimeter (sub-mm wave) Orotron Generators which can be used for both continuous wave (CW) and pulsed electron spin resonance (ESR) and electon paramagnetic resonance (EPR) experiments.
-
Product
Vibrating Fork Level Switch
RS85
-
The resonator utilizes a piezoelectric driven tuning fork that exhibits a large change in resonant frequency when immersed in any liquid. A "smart" microprocessor-based electronic unit keeps the sensor in a resonant state as it changes from dry to wet or wet to dry.
-
Product
Magnetic Resonance Instruments
-
Integrated Dynamics Engineering
MRI systems represent a significant investment. As magnetic resonance images can be distorted by electromagnetic fields, frequently the location is isolated by passive shielding to somewhat insulate the detectors from image distorting EMI. But for a fraction of the cost of the machine an active EMI compensation can fully protect the image from damaging fields generated by other electrical equipment, passing traffic, elevators or other nearby equipment.
-
Product
Passive Magnetic Antennas, TX-Loop Antennas
-
A passive loop antenna which is matched to a resonance frequency of 13.56 MHz with 370 kHz bandwidth (-3dB)The purpose of the antenna is to produce defined magnetic fields at 13.56 MHz efficiently, i.e. to test near field communication devices (NFC) or RFID equipment.
-
Product
Magnetic Property Characteristics Measurement System (from 100kHz to 14GHz)
-
KEYCOM’s magnetic property characteristics measurement system delivers ideal measurement solutions for complex permeability μr''- jμr'''', ferromagnetic resonance relaxation coefficient α, resonant line width ΔH in wideband from 100kHz up to 14GHz.
-
Product
Smart Card Module Test Cells
-
Current and voltage measures are executed on defined pins, in stable conditions.Measurements:- Open/short- Input leakage current- IDD Supply instant/average current test (static/dynamic mode)- Input capacitance @13 MHz and inductance- Retro modulation index (RMI)Test of passive devices:- Capacitors- Resistors- Resonators
-
Product
Accelerometers
352C33
-
Sensitivity (10 %) 100 mV/g10.2 mV/(m/s) Measurement Range:50 g pk 490 m/s pk Frequency Range (5 %)0.5 to 10000 Hz0.5 to 10000 Hz Frequency Range (10 %)0.3 to 15000 Hz0.3 to 15000 Hz Resonant Frequency:50 kHz50 kHz Broadband Resolution(1)0.00015 grms0.0015 m/s rmsNon-Linearity:1 %1 % Transverse Sensitivity:5 %5 %.
-
Product
Accelerometers
356A02
-
Sensitivity (10 %)10 mV/g1.02 mV/(m/s) Measurement Range:500 g pk4900 m/s pk Frequency Range: (5 %)1 to 5000 Hz1 to 5000 Hz Frequency Range: (10 %)0.5 to 6000 Hz0.5 to 6000 Hz Resonant Frequency:25 kHz 25 kHz Broadband Resolution (1)0.0005 grms 0.005 m/s rms Non-Linearity: (400 g, 3920 m/s)1 % 1 % Non-Linearity (500 g, 4900 m/s)2 % 2 % Transverse Sensitivity:5 % 5 %.
-
Product
Software and Interfacing
-
The installed sophisticated software offers many possibilities for signal storage, processing, visualization, etc. This includes the Fourier Transform analysis, and the line shape fitting of resonance. The system can also control external devices through the GPIB interface.