Standard Agreement
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
CPSI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from a Backplane Connector P1
MIC-3811
-
It is a dual mini-PCIe carrier board with two onboard SIM card holders and mini-PCIe connectors, routed by PCIe and USB2.0 interface. It allows connection with different types of Mini PCIe form factor add on cards like Wi-Fi/3G/4G LTE/GPS/DIO/CAN/ and MVB modules, either full- or half-size style.
-
Product
Dynamic Primary Transfer Standard
RD-22
-
The RD-22 Dytronic Primary Transfer Standard represents the state-of-the-art technology in a commercially available true DC to AC accuracy transfer reference. The RD-22 has typical AC measurement accuracies within the limits of traceability. Repeatability of 1 ppm can be attained at 120 V and 5 A inputs of specific models.
-
Product
Programmable S/R Standard & Simulator
5300
Simulator
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
Product
Standard Emission Monitoring System
CEMS-2000
-
CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.
-
Product
Standard Electromagnetic Vibrator
KD-9363-EM
-
King Design Industrial Co., Ltd.
The purpose of vibration testing is to make a series of controllable vibration simulation in lab, no matter generated by natural or man-made vibration environment; such as waves, tidal flaps, wind, earthquake or rain and so on. It is to test if the product is capable of sustaining the vibration environment exerted from transporting or usage along its effective life cycle; and certify the standard of design & functional requirement of product. The value of vibration testing is to confirm the reliability of products and effectively screen out the bad products in factory; avoiding damages occurred at arrival; and to assess the failure analysis on the non-performing products; expecting to reach a high standard, high-reliability products. The vibration test stresses on the continuity and fatigue; and contributes to the understanding of product’s status under vibration circumstance in a normal environment; and avoids the product’s unpredictable damage caused under certain vibrating frequency for a long time.
-
Product
Standard Lifetime Measurement System
Filter-Based Systems
-
*Excitation by bh ps Diode Lasers (BDS-SM or BDL-SMN Series)*Optional: fs Fiber Laser*Wavelength Selection by Filters*Detection by bh HPM-100 Hybrid Detectors*Excellent Dynamic Range*Ultra-High Time Resolution*IRF Width Down to 40 ps FWHM with HPM-100-06/07*Low Cost Detector Option: PMC-150 PMT Modules
-
Product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-C
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
FlexVNX+ Test And Development Platform Aligned To SOSA And VITA 90 Standards
39S08VPX98Y2VAN
-
Elma’s all-new FlexVNX+ Test and Development chassis is the next generation portable test platform designed to accelerate development and test of VNX+ plug-in cards (PICs) aligned to The Open Group® SOSA™ Technical Standard and VITA 90.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1Q1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3J
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-2V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-10
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
Product
Analytical Reference Materials & Standards
-
Agilent, now with former Ultra Scientific, offers a comprehensive portfolio of analytical standards, reference materials and certified reference materials for environmental, food safety, elemental analysis, instrument calibration, tuning mixes, and more.Reference materials and certified reference materials are substances that are tested to be homogenous and have fixed values of its concentrations. These standards are a critical component of your application workflow - from sample prep, instruments, columns, supplies, and services. The success of your analysis depends upon the quality of your reference material. All Agilent standard reference materials have been manufactured to the highest quality in an ISO 9001, ISO 17025 and 17034 accredited facilities to ensure the accuracy of your analyses.If you need a custom reference material, partner with us to design and develop a custom standard to your specifications.
-
Product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
-
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
Product
SiTek Standard PSD
1L20_CP3
-
The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.
-
Product
Standard Signal Isolating Amplifier
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation and conversion of standard signals. Calibrated switchable inputs and outputs 0/4 ... 20 mA and 0 ... 10 V signal duplicator with two electrically isolated outputs.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
Standards Source Instrumentation
-
PXI Arbitrary Waveform and Programmable Function Generators as well as DC source cards and a precision standards module.
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72F-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40C
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2SB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
Standard 1.00 (28.00) - 2.30 (65.00) Non Replaceable General Purpose Probe
P2532-1
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HC-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3T
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02





























