Microwave Probes
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1J-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1B-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1P-8-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXIe Microwave Relay, Single SPDT, 26.5 GHz, 50 Ω, SMA, External Termination, Failsafe
42-781A-321
Microwave Relay Module
The 40-781A-321 (PXI) and 42-781A-321 (PXIe) are single failsafe SPDT 26.5 GHz microwave relay modules with external terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 4-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-504
Microwave Multiplexer
Our 60-800-504 is a 4 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1UN-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-F180-2
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Alternate 2.14 (61.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-72I40-6
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-H100-3
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1L-10-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 1.10 (31.00) - 3.40 (86.00) Battery Probe
BIP-3-1
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25B-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
POGO-25HM-4 Probe
POGO-25HM-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 2,000,000Overall Length (mil): 1300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-C100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1T-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Threaded Step Probes
Step Probe
Pin position sensing - adjustable height - custom designs - anti-jump solution.
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25L36-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1L24-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1L-6-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25A-12
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1I-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
TSP157 Switch Probes
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
8 GHz Differential Probe with ProLink Interface
DH08-PL
Differential Probe
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1T-7
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25T36-8
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1H-6-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 12-Bank 6GHz SMA
60-801-012
Microwave Multiplexer
The 60-801-012 is a 6-channel, 12-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
6 GHz ProBus2 Differential Probe with Adjustable Tip
D600A-AT-PB2
Differential Probe
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25V-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02