Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
- Pickering Interfaces Inc.
product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Torque Calibration
ISO 17025 Accredited Calibration for Torque Screwdrivers, Torque Wrenches, Torque Multipliers, Torque Transducers, Torque Watches, and Torque Readout
-
product
Multiport Calibration Assistant
S97552B
This application provides a tool to flexibly create and manage calibration sets for multiport measurements
-
product
Automatic Calibration Module
ACM2506
ACM2506 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 6.5 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
product
250 and 260 Series pH Handheld Meter Kits
Get easy-to-read and accurate readings with auto-hold, auto-stable, and real-time measurements with stability indicators. The Environmental Express® Oakton® 200 series of water quality meters features an electrode status indicator, which shows the condition of the electrode after each calibration. Easily view electrode condition, reading stability, measured parameter, and temperature in one screen. Don’t worry about accuracy in fluctuating temperature—ATC ensures measurement accuracy. The simple...show more -
product
NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle
865684-01
NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9215, cDAQ-9171, and NI-9981 includes the NI-9215 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the NI-9981 Connector for strain relief and operator protection from high-voltage signals. The included NI-9215 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels.
-
product
Step Attenuator
RSC
The R&S®RSC is a switchable, mechanical step attenuator. It is available in various models with up to 6 GHz and 18 GHz, and can also control compact external units up to 40 GHz and 67 GHz. The base units provide a GUI for various settings, calibration and configuration of external modules. All models have RF connectors on the front panel or rear panel for rack installation
-
product
Pyrometer Calibration
Tempsens offers calibration of Non contact temperature sensors i.e. Infrared pyrometers traeceble to both national and international standards. Infrared thermometers can be calibrated at our NABL accredited laboratory, from 0ºC to 2900ºC utilizing state-of-the-art blackbody sources.
-
product
Manual Semiconductor Metrology System
Front USB port enables easy storage of measurements and other data to flash drivesMTI Instruments’ Proprietary Capacitance Circuitry for Outstanding Accuracy and DependabilityNon-contact measurements76-300 mm diameter wafer rangeOptional wafer measurement ringsWafer stops for exact centeringEthernet interfaceFull remote control software (Windows compatible)Optional calibration wafers
-
product
Mechanical Coating Thickness Gauge
211
This is one of the most popular mechanical coating thickness gauges in the world.Factory calibrated - with user calibration adjustmentFoils supplied to check calibration on siteIdeal for cold surfaces and underwater useSmall and portable with an accuracy ±5%The “V” grooved base, ideal for pipeline inspectionAvailable in either Metric or Imperial versions, the Elcometer 211 measures coatings up to 6mm (250mils)
-
product
1.533 Μm Frequency-Locked Laser
Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MH...show more -
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level o...show more -
product
Active Monopole Antenna
AM-741
The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the ...show more -
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
product
Process Calibrators
Handheld, battery-powered instruments used for field testing and calibration of industrial process equipment.
-
product
Data logger for Temperature Humidity and Differential Pressure
DSR-THDP
Simultaneously measures and logs temperature, humidity and differential pressure Support on-line linear calibration and zero setting Customized differential pressure measuring range between 0 and 1000Pa Suitable for pharmaceutical workshops, electronic production, precision machinery and other applications
-
product
Repair/Calibration & Refurbishing Services
metrology equipment services, LLC
We have highly trained engineers to provide In-house repair and calibration services. Service Blanket Accounts are offered to customers with multiple systems. Loaner systems provided at no cost during system repairs and calibration. 3-5 business day turnaround guarantee on equipment repairs. All repairs and calibrations are covered under a 90-Day warranty.
-
product
Thermometer Hygrometer
H3531-2
Sensor H3531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Sound Level Calibrators
PeakTech Prüf- und Messtechnik GmbH
For sound level measurements in extreme conditions, at high altitudes or high demands on the accuracy of the measurement results, sound level meters should be checked prior to the measurement with a sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed frequency characteristic. This calibrator has two switchable calibration steps.
-
product
Service Management Software
CERDAAC
CERDAAC® is an advanced software service that integrates calibration, maintenance, and service management for assets serviced by SIMCO, internal departments, or other service vendors.A secure cloud-based service, CERDAAC is a proven solution that helps thousands of organizations increase efficiency, improve compliance, and reduce costs. CERDAAC provides advanced asset and service workflow management and visibility into service status, program spending, quality compliance, key performance metrics, and more.Learn more about CERDAAC Service Manager and SIMCO Manager, as well as the optional Compliance Module.
-
product
ECU & Bus Interface Modules
ES500
ETAS makes the entire software and hardware range available from program development to the calibration of your ECUs. You can use the ETAS tools to address all ECUs that satisfy the ASAM standard. By using these standardized interfaces, our tools are not limited to the ECUs of any particular manufacturer.
-
product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
Multilogger
M1200
Universal datalogger with 4 inputs for thermocouples K, J, S, B, T, N. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
-
product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
product
PXI Strain/Bridge Input Module
PXI Strain/Bridge Input Modules feature up to eightchannels that support quarter-, half-, or full-bridge sensors at speeds up to 102.4kS/s. The modules provide increased accuracy, high data throughput, and a range of synchronization features. Optional features include remote sensing, internal bridge completion, and shunt calibration options per channel. PXI Strain/Bridge Input Modules are ideal for dynamic strain, load and pressure measurements, and test cell installations requiring accuracy and flexibility.
-
product
Terminations (Loads)
Loads find wide use as accessories for both broadband and narrowband measurement instruments. Keysight's family of fixed and sliding loads includes both general purpose grade loads as well as loads intended for use as calibration standards.
-
product
Absolute Moisture Meters
Explore PCE Instruments' absolute moisture meter offerings. Our absolute moisture meter products can measure relative air humidity, while our combination devices can also measure temperature. Each absolute moisture meter measures different ranges of humidity, depending on the model. Relative humidity is an important factor in everything from gardening to transport and industry.Our absolute moisture meter products are versatile, as they can take measurements, store the data to memory and transfer...show more -
product
Optical Receiver Stress Testers
Developing next-generation optical receiver technology requires world-class stress testing. Use Keysight's automated calibration solution and get optical stressed eye results in one-tenth the time compared to a manual setup.