Wavelength
See Also: Wavelength Meters
-
Product
Compact Tunable Laser Source with Continuous Sweep Mode, 1520nm to 1630nm
81940A
Laser Source
Keysight's 81940A high power compact tunable lasers enables optical device characterization at high power levels and measurement of nonlinear effects. It's improves the testing of all types of optical amplifiers and other active components as well as broadband passive optical components. As single slot plug-in modules for Keysight's 8163A/B, 8164A/B and 8166A/B mainframes, they are a flexible and cost effective stimulus for single channel and DWDM test applications. Each module covers a total wavelength range of 110 nm in the C+L-band.
-
Product
3-Port ROADM / TOADM
-
Optoplex's Reconfigurable Optical Add/Drop Multiplexer (ROADM) module, also known as Tunable Optical Add/Drop Multiplexer (TOADM), is based on a proprietary micro-optics and micro-actuator design, athermal packaging technology, and state-of-the-art thin-film coating. When receiving a stream of optical signals of a plurality of wavelengths from the Input-Port (IN), this 3-port ROADM device directs a selected channel to the Drop-Port (ADD/DROP) and the remaining channels to the Express-Port (EXP), as depicted in the figure below. This tunable feature can also be used for adding a channel, when the device is used in reverse. Cascading two ROADM modules, simultaneous add and drop functions can be achieved. Each single ROADM device is optimized to cover either C- or L-band wavelengths. The standard 100- or 200-GHz channel spacing ROADM products allow for single-channel drop. Customized banded-channel drop ROADMs are available upon request.
-
Product
UV-Visible/NIR Microspectrophotometers
MSV-5000 Series
-
Microscopes that use a high resolution double-beam scanning spectrophotometer for precise and accurate measurement in the wavelength region 200-2700 nm.
-
Product
FLIM Upgrades for Olympus
FV1000
-
*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excitation by bh ps Diode Lasers*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Detection Wavelength Range from 360 nm to 900 nm*Excitation by Ti:Sa Laser, OPO, or by bh ps Diode Lasers*Systems for Multiphoton FLIM and Confocal FLIM*Systems are Modular: More FLIM Channels can be Added
-
Product
Ultrafast Photodetector with Current Monitor, 700 - 870 nm, DC - 25 GHz, FC/PC
DXM25CF
-
The DXM25CF Ultrafast Detector is a DC - 25 GHz, fiber-coupled, GaAs-based photodetector designed for applications in the 700 nm - 870 nm wavelength range. The core element of the detector is the fiber-coupled, hermetically sealed, microwave detector module. For convenience and simplicity of use, the module is mounted inside a rugged housing that includes a rechargeable battery, current monitor circuitry, and a digital display of the DC photocurrent.
-
Product
Photonic Hall Effect
HMS7000
-
Classic hall effect measurement system is to read voltage difference made between both diagonal sides, when flowing current and applying magnet field strength, in perpendicular to flowing current direction. - Photonic hall effect measurement is to read various electrical properties by illuminating light of “various range of wavelength” on the sample, in addition to flowing current and applying magnet field strength. - It is great to see “RGB (Red, Green, Blue), Light intensity vs carrier density, carrier mobility, resistivity, hall coefficient”
-
Product
Fuorescence LED Illumination System
pE-2
-
The pE-2 is a fluorescence LED illumination system which provides repeatable and controllable light with a choice of 20 different LED peaks. It is perfect for the researcher who has a specific set of tests to conduct. The user can specify a wavelength configuration matched to their particular fluorescence requirements. It is modular, allowing LED wavelengths to be exchanged as requirements vary or additional experiments are added. Manual control is via a remote control pod with instant on/off and intensity control from 0-100%. Additionally, the system is fully integrated under many imaging software packages.
-
Product
Drives & Controllers
-
Most popular, Works with all McPherson SpectrometersDrive of Choice for high precision wavelength control settingUp to 50,000 steps per revolutionComputer control, RS232 (provided with USB adapter)Maintains all manual monochromator controlAvailable with fit kits to upgrade older instruments
-
Product
Compact Laser Diode Modules: 635nm-639nm Visible Wavelength, 11mm Diameter
-
The Optoelectronics Company Ltd
Custom lasing wavelengths, from 405 nm to 852 nm, output power options and laser engraving are available to your specifications. Both standard and custom configurations provide complete cost-effective laser solutions.
-
Product
Fixed Wavelength CW Laser Source (DFB)
Laser 1200 Series
Laser Source
The Laser 1200 Series is a highly customizable fixed-wavelength Continuous Wave (CW) laser source available in a wide range of wavelengths and powers.With seamless PXI integration, it can be easily integrated into new or existing PXI test setups. Save space, lower your costs and improve testing efficiency while delivering reliable and repeatable results in production or research environments.
-
Product
X-ray Fluorescence, XRF Analysis Services
-
Two XRF systems are available, a wavelength dispersive system (WDXRF) and an energy dispersive system (EDXRF). The difference is the manner in which the x-rays are detected. WDXRF instruments have very good energy resolution which leads to fewer spectral overlaps and improved background intensities. EDXRF instruments have higher signal throughput which can shorten analysis times. The higher signal throughput also makes EDXRF systems suitable for small spot or mapping analysis.
-
Product
Optical Fiber 1×32 Switch
OFSW - 1 × 32
-
Hangzhou Huatai Optic Tech. Co., Ltd.
OFSW- 1×32 is a 1×32 prism optical switch. It can support 1 optical fibers input and 32 fiber output, channel switch. Wide operating wavelength range, low insertion loss and speedy switching rate, can use network trends configuration, network monitor and lab application.
-
Product
Laser Power Meter Calibration Services
-
Following the successful setup of our UKAS accredited laser testing laboratory we have now set up a calibration laboratory in our Bournemouth premises for the purpose of offering laser power meter calibrations. We are able to undertake NPL traceable calibration of laser power meters at any of the following wavelengths:
-
Product
Reflectance Standards
STAN Series
-
Ocean Optics offers specular reflectance standards for measuring shiny surfaces such as machined metals and semiconductor materials and low-reflectivity surfaces such as anti-reflective coatings and thin film coatings. The STAN-SSH varies in reflectivity from 87%-98% over the 200-2500 nm wavelength range and is available in a version (STAN-SSH-NIST) calibrated to a NIST master standard. The NIST calibration data range is 250-2500 nm.
-
Product
1.533 Μm Frequency-Locked Laser
-
Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.
-
Product
Polarization Maintaining Fused Wavelength Division Multiplexer (
-
Zhongke Rayzer Optical Technology Co.,Ltd
Polarization Maintaining Fused WavelengthDivision Multiplexer product, has thecharacteristics of low insertion loss, high handing power, high extinction ratio and double-axis operation. It is mainly used in the fields of polarization-maintaining fiber laser, polarization-maintaining amplifier, polarization-maintainingsensing system and scientific research application.
-
Product
Optical/Laser Power Meters
-
Sanwa Electric Instrument Co., Ltd
Laser Power Meters measure the energy output of laser beams for testing or laser system applications. Laser Power Meters use detection sensors to determine the intensity of a laser beam's energy output. Laser Power Meters are designed to analyze lasers within a particular range of wavelengths or intensities.
-
Product
Power Meter
-
OrienTek Optical Technology Ltd.
Power Meter and the Visual Fault Locator.The Optical Power Meter can measure dBm,dB and uW in the wavelength band of 850,1300 1310 1490 1550 and 1625nm.The Visual Fault Locator uses CW mode and Modulation mode and helps to detect the optical cable of up to 10km. Battery performance 50 hours operation,Dust and shock proof design,Auto Shut off function.
-
Product
Calibration Light Sources
-
For wavelength calibration, Avantes offers a variety of sources including Argon, Mercury-Argon, Neon, Zinc, and Cadmium. All Avantes spectrometers are factory wavelength calibrated and do not require recalibration as they have fixed slits and optics. For those customers who wish to do their own calibrations, the AvaLight-CAL light sources can be used for recalibration purposes. For auto-calibration, AvaSoft-Fill provides a calibration procedure to make this easy.
-
Product
Optical Wavelength Meter
-
An Optical Wavelength Meter measures the peak wavelength(s) of an optical signal with extreme precision, often to picometer and sub picometer accuracy.
-
Product
Fluorometers
-
A fluorometer, fluorimeter or fluormeter is a device used to measure parameters of visible spectrum fluorescence: its intensity and wavelength distribution of emission spectrum after excitation by a certain spectrum of light.[1] These parameters are used to identify the presence and the amount of specific molecules in a medium.
-
Product
Laser Modules
-
The piezo laser modules include an attenuator, a filter wheel, an X-Y aperture, and a rotating waveplate. These compact laser modules can be integrated independently or can be daisy-chained together into laser beam delivery systems and have a damage threshold of 5 J/cm2. Attenuator modules connected together can also provide independent control of energy in multiple wavelength systems.
-
Product
Optical Power Meter W/6 Wavelength Calibrating Spots
-
With six wavelength calibrating spots (980nm, 1310nm, 1490nm, 1550nm, 1590nm and 1610nm), refined design, easy operation, linearity or non-linearity display, SC connector, the MXOPM26-50 hand-held optical power meter can be used for direct optical power measurement as well as relative measurement of optical link loss. It’s an essential test instrument in Optical Communication systems, CATV systems, construction and maintenance applications and more.
-
Product
Mini Power Meter
MPM-100
-
•Very small and lightweight•Communicates with Smartphone via USB / Bluetooth•Communicates with PC via USB•Smartphone application software and PC Software•Internal data storage up to 100 measurements•Pass/Fail indication for in-field compliance•Li-ion Polymer rechargeable battery•Battery charging via a USB interface•Universal 2.5mm adapter to accept FC, SC or ST (1.25mm adapter option)•Up to 22 Factory-calibrated wavelengths (nm)850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625
-
Product
Optical Light Sources
FLS200 Series
-
Shanghai Tarluz Telecom Tech Co., LTD
FLS200 Optical Light source could provide maximum 4 wavelengths in one unit, customer could select arbitrary four output wavelengths from 650nm, 850nm, 1300nm, 1310nm, 1490nm, 1550nm. The unit support Single mode and Multimode (50/125um or 62.5/125um MM fiber) optical cable in one unit. It could support FC, SC, ST, LC and 2.5mm universal optical connector.
-
Product
C-Band DWDM Pre-Amplifier EDFA (WPA-C)
HWA4300 (With SNMP)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HWA4300 series, is designed for C-Band 44 waves or 88 waves DWDM system design Pre-Amplifier gain flatness. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, Low noise, excellent gain flatness characteristics and transient characteristics.
-
Product
Plastic Optical Power Meter
POFPM100
-
Shanghai Tarluz Telecom Tech Co., LTD
POFPM100 POF OPM used for the plastic optical fiber within 600 ~ 1000nm wavelength range, w, dBm units, five calibration wavelengths.
-
Product
Optical Power Meter for 400-1550 nm Wave
F-712.PM1
-
Physik Instrumente GmbH & Co. KG
This photometer can convert an optical signal into a voltage signal in high resolution and with an extremely high bandwidth. The design of the optical input enables measuring of the optical signal independent of the position of the optical fiber in the connector. Wavelength range: 400 to 1550 (1) nm
-
Product
1.5µm PM Ev-Yb Fiber Amplifier ( PM EYDFA )
HAPM5000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HAPM5000 is a C-Band Polarization Maintaining Optical Amplifier which worked in 1540~1570nm operating wavelength. Adopt Polarization Maintaining (PM) Multiclad Ev-Yb fiber, output optical power range 27~37dBm(0.5W~5W) , extinction ratio >20dB.





























