Resistive Load Banks
Check power source's ability to deliver a given current and voltage at unity power factors.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks
-
Product
Earth Resistance Tester
M71
-
M71 has been developed to measure earth resistance with 2 wires and 3 wires by voltammetric method in compliance with standard IEC/EN61557-1.
-
Product
Resistance Standards
-
Ohm-Labs manufactures reference grade resistance standards from 10 micro-ohms to 10 teraohms. Each range of standards utilizes the latest advances in materials and processing for high stability and immunity from changes in ambient environment. All products are supplied with ISO17025 accredited calibration.
-
Product
Resistance Measurement Meters
-
Shanghai Beha Electronics Co., Ltd.
The meter digital milli-ohmmeter is a battery operated instrument wich supply a low current to the circuit under test, with which, stable, accurate measurement of low resistance can be made, still, over a wide range of values.
-
Product
Resistivity Standard
-
Resistivity Standards are bare silicon wafers available in 3 in, 8 in and 12 in sizes. The silicon is p-type (Boron) doped to nominal resistivity values, from 0.002 ohm.cm to 75 ohm.cm as available on the 3" model.
-
Product
Insulation Resistance Measurement
MI15KVe
-
The MI-15KVe High-Voltage insulation tester is a truly portable device that allows the measurement of insulation resistances using test voltages up to 15kV.
-
Product
Load Cell Indicator
9840
-
The 9840 is suitable for use in calibration labs, field service, or anywhere high accuracy is important. Features include a bipolar 6-digit 2-line display, remote sense, low noise, 22-bit resolution, USB port with RS232 communication, mV/V calibration and the ability to store up to 25 different sensors. 6-point linearization, unit conversion, front-panel tare. Self calibration via TEDS Plug & Play ready IEEE1451.4 compliance.
-
Product
Resistance Bridges
-
Provides the best in measurement uncertainties for Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.
-
Product
Bending Beam Load Cell
-
Futek Advanced Sensor Technology, Inc.
Are the best fit for many measuring tasks. Here, the signal, on principle, depends on the bending moment.
-
Product
Battery Load Bank
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
Product
Contacts Resistance Tester
JYK II
-
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
Product
Button Load Cell
3000 Series
-
Button Load Cells are strain gage based transducers with temperature compensation and excellent overall performance. This type provides a range of capacities up to 150 kN or 30 klb with better than ±0.5% (full scale) non-linearity. Three tapped holes are provided on the underside for ease of mounting. Fully welded cover, amplified and digitised versions are available on request.
-
Product
Motive Power Load Banks
-
The only way to be certain that your stationary batteries will perform to specification is to test the batteries’ capacity with a DC load bank / portable battery discharge tester.
-
Product
Winding Resistance Meter
TRM 25
-
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Battery Load Tester
BT-100
-
Schumacher Electric Corporation
FOR EVERYDAY DIY USEEasy to operateTest load, battery condition, starter motor draw and complete charging system diagnosis.Works on 6 and 12 volt batteries50 amp load test for 6 volt batteries100 amp load test for 12 volt batteries Tests 6 and 12 volt batteries ─ up to 1000 CCATop-mounted rocker switch for easier operationSuper-grip, heavy-duty color-coded battery clampsEasy-to-read meter ─ accurate and shock resistantBaked enamel, steel case ─ ventilated to keep coolRubber insulated carrying handle ─ for comfort and safety
-
Product
Programmable DC Electronic Load
IT8500+ Series
-
IT8500+series (150W~3000W) single-channel programmable DC electronic loads are designed for middle & high-end applications. They can be offered as multiple solutions according to customer's design and testing requirements.
-
Product
DC Resistance Tester
DCSS502BC
-
Resistance meter is designed to measure copper resistance of transformers, wires, cables, other conductors and other coil products etc. It is widely used of low resistance measurement of switches, heater wires, transformers, relays, motors, electric films and PC circuit boards, wires, cables, etc. With reliable Good/ NG judgement, it is a premier resistance meter for the use in production line or QC department.
-
Product
Resistance Thermometry Bridges
-
By using built-in or external standard resistors, resistance thermometry bridges measure resistance ratios with high accuracy, which are indicative of the temperature, among other things. These instruments are not only used in the field of temperature measurement, but − due to their high accuracy − also in electrical laboratories.
-
Product
Winding Resistance Meter
-
* Selectable four resistance ranges.* 4 1/2 digits LED display* High measurement Current (10A)* True four Technique elimanates lead resistance errors Systems* Fully protected against overloads* Proven design* Computer connectivity through RS 232
-
Product
DC Electronic Load
-
Siglent SDL1000X series Programmable DC Electronic Load features an input range up to 150V/30A/300W. CC Dynamic mode frequency is up to 25 kHz. It delivers stability over a wide range of applications and can meet all kinds of testing requirements including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.
-
Product
Outdoor Permanent Mounted Load Bank
-
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
Product
Shear Beam Load Cell
SB-1.0
-
The Shear Beam Load Cell SB-1.0 is a single point weighing device, suitable for use in multiple applications.
-
Product
Top Loading Industrial Ovens
-
Gruenberg manufactures two, specialty industrial top loading ovens that are designed for multiple processes, including annealing, preheating and baking. Their rugged durability are well suited for oil and gas applications. Standard and custom options accommodate a variety of processing applications including drying, curing, baking, aging and more.
-
Product
Bi-axial Dynacell Load Cells
2527 Series
-
During tests carried out on servohydraulic machines, elements of the system are subject to acceleration. As a result, in addition to the force applied to the specimen, the load cell also reads forces resulting from its own movement and the mass of the grips and fixtures attached to it. Dynacell is the world's first truly dynamic load cell, designed from the outset for measuring dynamic loads. Dynacell introduces the following advantages:*Reduces dynamic load errors which can be a significant percentage of reading *Increases productivity by allowing higher frequency operation while maintaining test validity *Improvements such as doubling the frequency are common
-
Product
Regenerative AC load function
61800 Series Optional Function
-
The regenerative AC load function consists of various modes such as CC Rectified mode, CP Rectified mode, CR mode, CC Phase lead/lag mode and CP Phase lead/ lag mode. The Rectified Mode is capable of simulating non-linear rectified loads with characteristics similar to Chroma 63800 series AC load where the voltage and current operate at the 1st and 3rd quadrant. The Rectified Mode supports both CC and CP functions with current, power and CF as parameter settings.
-
Product
SparkFun Load Sensor Combinator
-
The SparkFun Load Sensor Combinator is a bare PCB that combines four load sensors into a standard four-wire Wheatstone bridge configuration. If you open up an electronic bathroom scale, you’ll find a large rat's nest of wires. The Load Sensor Combinator was created to combine the 12 wires found in a bathroom scale into the standard four-wire Wheatstone bridge configuration.
-
Product
Load Cell Indicators
-
Procter & Chester Measurements Ltd
The instrumentation will power the load cell. The mV/V signal coming back from the load cell is converted by the indicator and displays the force in a unit (e.g.: Kg, kN, lb – customers choice). The indicators within this range are encased so that the operator can either use it on the move (if battery powered) or be a permanent fixture, e.g.: wall mounted.