Showing results: 2791 - 2805 of 2914 items found.
-
DSAV334A -
Keysight Technologies
33 GHz analog bandwidth4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV254A -
Keysight Technologies
25 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSOV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOS404A -
Keysight Technologies
4 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.2 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
E5072A -
Keysight Technologies
30 kHz to 4.5 GHz & 8.5 GHz2-portImprove accuracy, yield and margins with wide dynamic range 130 dB / 151 dB (direct receiver access), measurement speed 7 m sec and excellent temperature stability 0.005 dB/C Increase test flexibility with wide source power range -109 to +20 dBm for linear and nonlinear device characterization Protect your investment with upgradability across all of the options Every spec verified, adjustments included Lock in support & peak performance from the start
-
DSOV084A -
Keysight Technologies
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOS254A -
Keysight Technologies
2.5 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.4 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
MSOS604A -
Keysight Technologies
6 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 6.8 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
DSOV334A -
Keysight Technologies
33 GHz analog bandwidth4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOS204A -
Keysight Technologies
2 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.5 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
DSAV134A -
Keysight Technologies
13 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
U5532C -
Keysight Technologies
The U5532C USB power sensor module is specially design for the N5531X measuring receiver. Based on the Keysight USB power sensor and a power splitter, the U5532C provides the N5531X measuring receiver user with a single RF input device covering up to 50 GHz. Using of the U5532C USB power sensor module eliminates the requirement of an external power meter, simplifying the setup process and saving lab space. The measurement integrity and accuracy are guaranteed by the fully defined specification sets. The traceability of measurement uncertainties is also ensured.
-
Aaronia AG
The highly transparent EMC shielding material Aaronia-Shield® and the high-tech EMC shielding fleece Aaronia X-Dream®, for example, offer very high EMC protection and are especially well equipped for all future high-frequency radiation sources in the high GHz range, which you can easily verify with our EMC Handheld Spectrum Analyzer. For magnetic field shielding, our MagnoShield® series offers unparalleled protection against alternating magnetic fields, such as cables, power distributors, high-voltage lines or transformers and generators.
-
LSG Series -
Vaunix Technology Corporation
The Lab Brick LSG series of low cost USB-compatible RF and microwave signal generators covers frequencies from 20 MHz to 6 GHz with high output levels and excellent spectral purity. They require no additional DC supply voltage and offer several operating modes, including continuous-wave (CW) and swept-frequency. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.