Showing results: 1606 - 1620 of 2943 items found.
-
GPS161 -
INSTOCK Wireless Components, Inc
Wideband Frequency (1000-2000 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsTri Alloy SMA Female (Jack) Low PIM
-
dbSAFE TSE -
DVTest Inc.
Compatible with all platforms of temperature forcing units and thanks to the DVTEST “waveguide” technology; isolation performance will not be impacted. The temperature range of the units will be -90°C to +220°C.
-
CK521A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK520A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Insight Product Company
Insight Product Company offers a high-power synthesizer of pulsed signals. They are ideal for ESR, EPR, and DNP experiments. The synthesizer has a high frequency stability (10-6), and allows control over the duraction and begining time of pulses. The synthesizer also enables phase manipulation, where each pulse is shifted by 90 or 180 degrees relative to the previous pulse. In contrast with the PIN modulators and injection-locked power amplifiers this synthesizer has absolutely no residual signal in the "OFF" position.
-
42-781A-921-LA -
Pickering Interfaces Ltd.
Externally terminated switches have the advantage that the terminations can be removed and replaced with higher power RF loads. This also allows alternative configurations such as terminated 4-port bypass (1 termination removed) and 5-port DP3T (both terminations removed). See the datasheet for diagrams of these configurations.
-
42-781A-922-LA -
Pickering Interfaces Ltd.
Externally terminated switches have the advantage that the terminations can be removed and replaced with higher power RF loads. This also allows alternative configurations such as terminated 4-port bypass (1 termination removed) and 5-port DP3T (both terminations removed). See the datasheet for diagrams of these configurations.
-
M4I.2221-X8 -
Spectrum Instrumentation
The 9 models of the M4i.22xx-x8 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
M4X.2220-X4 -
Spectrum Instrumentation
The 9 models of the M4x.22xx-x4 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
M4X.2230-X4 -
Spectrum Instrumentation
The 9 models of the M4x.22xx-x4 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
M4I.2230-X8 -
Spectrum Instrumentation
The 9 models of the M4i.22xx-x8 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
M4I.2220-X8 -
Spectrum Instrumentation
The 9 models of the M4i.22xx-x8 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
M4X.2221-X4 -
Spectrum Instrumentation
The 9 models of the M4x.22xx-x4 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
85514A -
Keysight Technologies
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
85519A -
Keysight Technologies
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit