V.35
-
product
Ultra-Low Noise Filter, 42 V / 105 MA, 50 Ω
N1298B
The N1298 Series is a collection of low noise filters for the Keysight B2960 Series 6.5-digit low noise source.
-
product
16-bit, 100KHz, 8SE/4DIFF A/D Inputs; 8 14-bit, 30KHz D/A Outputs, 4 24V Digital I/O, All Isolated
APCI-3120-8-8
*Optical isolation 500 V*8 SE or 4 diff. inputs*Data transfer rate: 100 kHz*16-bit resolution*8analog output channels*Data transfer rate:30 kHz*14-bit resolution
-
product
Power Meter
2015 PM
Standard Electric Works Co., Ltd
● Determine the running cost of your appliances.● Measure voltage, current, frequency, watt, power factor, and greenhouse gas emissions.● Log and Recall function.● Enable users to read the data in memory directly on the meter without connecting to a PC. ● Optical USB to RS-232 data transmission.● 2 Optical LEDs are built-in for data transfer.● Transferring and showing real-time data to a PC.● Make informed decisions when purchasing appliances and equipment.● Reduce your electricity bill.● Calculate electrical expenses by real, hour, month. ● Data communication function.● Freely set upper and lower limit for V, A, W and alarm when measured value is out of limit.● Backlight function.
-
product
Universal Multichannel Low Voltage Power Supply System
SY8800
- Factory configured modular system- 5 free slots for power supply modules- 3U x 19″ x 35 cm crate size- Floating channels- Local and Remote Control- Remote control via Ethernet, USB, CANBUS and RS232- Max output power: 2.5kW @ 220Vac, 1.5kW @ 115Vac- Up to 8 independent channels- Low noise
-
product
AC Power Source
61600 Series
Built-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable voltage,current limitComprehensive measurement capability,V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlOne-key recall for 9 different voltage and frequencyProgrammable slew rate setting for changing voltage and frequencyAnalog input for power amplifierOptional Analog programming interfaceOptional GPIB and RS-232 interface(Model 61601~61605)Full protection: OP,OC,OV and OT protectionEasy use graphic user interface: softpanel (option)Capable of delivering power output up tp 90KVA by implementing Master-Slave operation
-
product
Power Supply, 100 V, 50 A, 5000 W
N8759A
The Keysight N8759A power supply is a single output power supply in a small 2U package that offers essential features to fit your budget. The N8759A power cable offers flexible AC input options, analog / resistance control of output voltage and current, as well as parallel and series connection of multiple supplies to achieve more output current or voltage.
-
product
CL LX1 Base Frame Grabber
Xcelera-CL LX1 Base
Building on the field proven technology and performance of DALSA’s X64 frame grabbers, the X64 Xcelera™ Series leverages the PCI Express (PCIe) platform to bring traditional image acquisition and processing technology to new levels of performance and flexibility.The PCIe point-to-point host interface allows simultaneous image acquisition and transfer with little intervention from the host CPU.The X64 Xcelera -CL LX1 Base is a cost effective frame grabber based on the PCI Express x1 interface. Fully compliant with Camera Link (V. 1.20) specifications, the Xcelera-CL LX1 supports single Base cameras and can acquire images from a wide variety of multi-tap area and line scan, color and monochrome cameras.
-
product
Thyratrons, Ignitrons & Spark Gaps
High power switches such as ignitrons, thyratrons, and spark gaps require unique high power triggering systems. Our triggers can all operate from 5 mA/5 V sources and/or fiber optic inputs.
-
product
Digital I/O
With digital I/O cards, static or dynamic bit patterns can be generated or recorded. Each bit is assigned a control signal for an output and a sensor signal for an input. The usual voltage range for the inputs and outputs is between 2 V (TTL) and 24 V (automation).
-
product
NI-9472, 24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module
783907-01
24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module - The NI‑9472 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 30 V, … features transient overvoltage protection between the output channels and the backplane, and has an LED that indicates the status.
-
product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
product
Digital AC/DC Auto-Ranging Clamp Meter
PCMT20
Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit
-
product
Clamp Meter, Auto, True RMS, 1 kA AC, 600 V AC
72-9490
A professional digital clamp meter that is perfect for any industry. Measures AC/DC voltage, AC/DC current, Resistance, and Frequency.
-
product
PXI-6704, 16-Bit, 32-Channel, Static PXI Analog Output Module
777796-01
16-Bit, 32-Channel, Static PXI Analog Output Module—The PXI‑6704 is a static analog output device. You can use the PXI‑6704 to create software-timed voltage and current output applications. You can independently set the output voltage range on each channel. The PXI‑6704 also includes eight 5 V TTL/CMOS digital I/O lines.
-
product
PCI Digital IO Board
*Bus Interface: PCI Bus*Counter/Timer: 16 Channels*Counter Size: 32 bit*Max. Source Frequency: 80MHz*Compatibility: 5 V TTL/CMOS*Discrete Inputs: 24 Channels*Discrete Outputs: 24 Channels*Pulse Generation: 12 Channels*Bi directional I/O's: 8 Channels*Oscillator stability: 50 ppm*Op-to isolation for I/O's*DMA buffered operation*16-bit data bus 32 bit Address bus for External Memory Interface*The Pulse Width and PRI of the pulses can be varied*The pulse generation frequency from 10Hz to 40MHz (25ns to 100msec)*The no. of pulses controlled from 1 to 255 pulses*All the pulse input and the output signals and Bi-directional write signals driven through Pin Driver*Driver interface for Windows2000/XP/VISTA and LINUX OS
-
product
3U CompactPCI Plus IO 8-slot SSR with power bolts
036-777
3U CompactPCI PlusIO Backplane 8-slot, PICMG 2.30 based hybrid Backplane, CompactPCI system slot right (PICMG 2.30), 4 CompactPCI slots 32 bit, V(I/O) +5V, 4 CompactPCI Serial slots PICMG 2.30 based slots, Rear I/O only in the peripheral slots
-
product
Proximity sensors
Voltage 0...250V DC, 230 V AC Cable length 0.3, 2.5, 5, 7.5, 0.2...10 m Plug connection M8, M12 / female thread M5 Electrical Via reed contact Contactless PNP, NPN Pneumatic.
-
product
Network Analyzers
MPR2 Series
Dimensions:DIN4 kVArh, Max, Min: available (available)% THD I: none (none) % THD V: none (none)Harmonics 1-51.: RS-485: none (none)Digital Input:Digital Output:Temperature Input:AOV:RLY: Memory:Current Voltage Unbalances: none (none) X5/X1: none (none)Plug & Meter: available (available) 85-300 VAC/DC: available (available)
-
product
In-line ICP® Charge Converters
In-line ICP® charge converters play a vital role in converting high impedance charge mode piezoelectric sensor signals into low impedance voltage signals, facilitating input to readout, recording, and analysis instruments. Specifically engineered for compatibility with high temperature piezoelectric sensors, these units are capable of operation in environments reaching up to 500°F (260°C). The series boasts ±2.5V or ±5.0 V output, offering a range of gain options, all packaged within a compact and durable casing. As a cost-effective alternative to laboratory charge amplifiers, in-line ICP® charge converters present an appealing choice for multi-channel applications.
-
product
Probes, Cables & Detectors
Probe has a mica window that has a thickness of 1.8 to 2.0 mg/cm2. This allows detection of alpha radiation as low as 3.0 MeV when in close proximity to the window. Beta radiation in excess of 35 keV and X-ray or gamma radiation greater than 6 keV can also be deteched. The detector is provided with a BNC connector. It can be used with most count rate and survey meters which accept Geiger Mueller (GM) detectors operating at 900V DC.
-
product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779373-02
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
785190-02
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.
-
product
Modules - Modules, Bridge
Vishay’s bridge modules feature voltage ratings from 50 V to 1600 V in single-phase and three phase configurations and in a wide range of package options.
-
product
True Rms Digital Insulation Multimeter
MODEL KM 887
Kusam Electrical Industries Limited
• VFD V & Hz readings• LCD Backlight Display• Record MAX/MIN regular readings.• Display Hold Function.• Dual Display +Hz readings.• Relative zero mode.• LOCK-Test mode for Insulation Resistance• BeepJack™ audible & visible input warning.• High resolution 60.00mV & 60.00 ranges.
-
product
PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit
APCI-3501-8
*8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated
-
product
2kV, 400 MHz High Voltage Differential Probe
HVD3220
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
PXI-4071, 7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter
778271-01
7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter - The PXI‑4071 is a high-performance 7½‑digit, 1,000 V DMM that provides the measurement capabilities found in two common test instruments: a high-resolution DMM and a digitizer. As a DMM, the PXI‑4071 delivers fast, accurate AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, and frequency/period measurements, as well as diode tests. In the high-voltage, isolated digitizer mode, the PXI‑4071 can acquire waveforms at sample rates up to 1.8 MS/s.
-
product
Software-controlled Generator
IPTN16
*The module provides output of constant stabilized voltage through 16 independent channels in 2 ranges ± 2 V and ± 10 V with a step of 5 mV, as well as a stabilized current of ± 10 mA with a step of 5 μA.The IPTN16 module is intended for use in information measuring VXI systems and can be used to power resistive temperature sensors or strain gauges with voltage or current with an accurate and stable value.*The IPTN16 module can also be used to simulate voltage or current sensors when checking measuring instruments and channels of measuring systems.
-
product
PCI-6519, 32-Channel, ±30 V, 16 Sink/Source Inputs, 16 Sink Outputs, Bank-Isolated Digital I/O Device
779085-01
The PCI-6519 is an industrial digital I/O interface, with two banks optically isolated channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6519 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6519 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.
-
product
3 Digit LCD Voltmeter
V 125
The V 125 is a very low cost 3 digit LCD voltmeter with 12.5mm (0.5") digit height, intended for high volume OEM applications. It features 200mV d.c. full scale reading, auto-zero and auto-polarity. The meter plugs directly into a SIL socket or can be panel mounted using the bezel provided. Connection to the meter is via one row of 8 pins





























