V.35
-
product
Coax, Contact, Receiver, 20/26 GHz, 3.5MM, w/ SMA Adapter, 90 Series Modules only
610102135
Primary mating contact 610102134. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination 3.5mm compatibleInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mΩ max. center conductor3 mΩ max. shieldCable Specifications 3.5mm compatible Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ min.
-
product
DC/DC converter 5 W
20IMX7-03-8G
DC/DC converter 7 W from Bel Power Solutions | input ranges 8.4 - 36 VDC | output 3.3 V | operates in ambient temperature from -40 to +85 °C
-
product
AC / DC Current Probe, 100 KHz, 100 A
1146B
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
product
PXI/PXIe High Voltage Multiplexer, Hex 7-Channel, 2-Pole
40-321-123-HI
The 40-321-123-HI (PXI) and 42-321-123-HI (PXIe) are hex 7-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Microprocessor Based Indicator
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
product
96-Pin Female DIN to 88-Pin Female Screw Terminal, 10 V, PXI Module Mount Terminal Block
781347-01
NI TB-4330 Terminal Block for PXIe-4330
-
product
NI-9775 , ±10 V, Up to 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module
784539-01
The NI-9775 provides referenced single-ended analog inputs with two timing modes for applications such as fault detection in electrical transmission lines or structural failure events. You can use the NI-9775 to measure finite samples up to 20 MS/s/ch to capture fault detections or to measure continuously at up to 4 MS/s. You also can use the built-in analog reference trigger to assist with high speed phenomena. Additionally, the NI-9775 supports waveform streaming at a lower sample rate.
-
product
LOAD CELLS From UTILCELL
For more than 35 years, UTILCELL has been the national market leader for load cells and is now one of the five leading manufacturers in the world. The load cells are used in small scales, personal scales or retail scales, industrial scales, filling and packaging scales, truck and train scales and other applications.
-
product
Single Channel Analyzers
Alpha Moisture Systems' range of single channel moisture analysers have been developed to meet the requirements of all applications, requiring on-line analysis at a single sample point. These instruments combine robust construction and advanced electronics to ensure that they will provide accurate moisture analysis through a long and reliable service life.Unless stated otherwise, all on-line analysers are used in conjunction with any of our range of dedicated Ultra High Capacitance moisture sensors covering an overall range from -110ºC to +20ºC dewpoint, 0.001 to 23,000 ppm(v). Please contact us for further information.
-
product
System Test
Testing a complete system is very different from unit and integration test. It starts with the V model that defines the system requirements, and this needs an effective system test capability that includes both the system and the environment around it. If the system has interfaces to the outside world, communications links or human control, these interfaces have to be tested.
-
product
Autoranging System DC Power Supply, 500 V, 30 A, 5000 W, 208 VAC
N8923A
The Keysight N8900 Series provides 5 kW, 10 kW, and 15 kW autoranging, single-output programmable DC power for ATE applications that require just the right amount of performance at just the right price. The N8900 Series power supplies' autoranging output characteristic enables unprecedented flexibility by offering a wide range of voltage and current combinations at full power. Power supplies with "rectangular," or traditional, output characteristics provide full power at only one voltage and current combination. Just one N8900 does the job of multiple power supplies. It's like having many power supplies in one!
-
product
Micro Coax, Two Piece Contact, ITA, PCB Vertical Mount, Solder
610141109
For vertical PCB terminationsUsed with standard 50 and 120 Pin Micro Coax ModulesUp to 10GHz transmission speeds (PCB design dependent)Two-piece contact that allows for pin replacement, field repairableMates to all existing Micro Coax contactsMechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 10 GHzVSWR 1.59 @ 10 GHzInsertion Loss – √f(GHz) x .325 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Salt Spraying Test Chamber
Sanwood Environmental Chambers Co ., Ltd.
Sanwood is glad to be the ODM/OEM manufacturer of Salt Spraying Chamber,Salt Spray Test Chamber,salt spraying test chamber,Salt spraying chamber,Salt spraying chamber sales enterprises all over the world! 1:It adopts 5mm or 8mm imported gray and white impact resistant P.V.C board, with high temperature resistance up to 85℃ and corrosion resistance. 2:Support frame: ¢ 10MM fiberglass rod, corrosion resistant. The steel V-frame and the fiber rod angle are placed to ensure the specimen is inclined at 15-30 degrees. 3:Pressure barrel is welded seamlessly with 2.0MMSUS304 stainless steel plate 4:The heating adopts titanium alloy electric heating tube. It has high corrosion resistance and long service life is 3-5 years higher than ordinary stainless steel heating tube. 5:The cover is made of 5MM imported transparent (Germany YLIS) acrylic sheet. It has fine workmanship, beautiful appearance and high transparency.
-
product
Acquisition Of 16 Displacement Transducers
APCI-3701-16
PCI interface to the 32-bit data bus Acquisition of 16 inductive displacement transducers (Half Bridge, LVDT) 16 input channels ± 10 V 16-bit resolution Measuring frequency up to 100 kHz Conversion can be triggered through software End of conversion can be inquired through software Possibility of interrupt through digital input channels (when a data or a time value is exceeded) PCI-DMA access Onboard FIFO buffers Sequence RAM 16 isolated digital I/O, 24 V Software operation Supported inductive transducers for APCI-3701Standard board APCI-3701-8 or APCI-3701-16Transducer type:
-
product
Battery Pack Rotate Test Device
Guangdong Bell Experiment Equipment Co.,Ltd
DGBell's Battery Pack Rotate Test Device Single storage cell safety testTest object: Battery storage pack or systemRotate the battery pack 360°around X axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Rotate the batter pack 360°around Y axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Accept standard: Battery pack or system has no electrolyte leakage, no rupture at case, no fire nor explosion. And remain the connection reliable, the structure intact, the insulation resistance value not less than 100 Omega /v.
-
product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
product
Bench Power Supply, Linear, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690
The 72-2690 from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
product
Emergency Power Supply Units (EPSU) (24) 5-20R 0U V
EPS-2420-V60
EPSU Power (Basic / Surge / Metered / Value) – rack mountable power distribution, 120V, optional surge suppression, and amp meter
-
product
RADAR
ARA designs and manufactures an array of Marine RADAR and Perimeter Surveillance Antennas covering S-band and X-Band frequency ranges. Our Division in Pembroke, MA, offers either linear or circular polarized products with 27 dBi to 35 dBi of gain.
-
product
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip
D410-A-PB2
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
ADI Test Fixture
TA-6500
The TA-6500 test fixture combines the features of the OEM's Instrument Servo Tester(T307962), the Pointer/Flag Test Fixture(T307951) and the AD-650/600 Test Panel(T334043) all into one panel to facilitate testing of these Attitude Director Indicator's. The panel switches and adjustment pots are labeled to match the test procedure numbers and the duplicity in marking makes it easier for the technician to understand each function. The UUT interface is through a 96 pin zero insertion force(ZIF) type connector to minimize contact wear. The expanded localizer and nav input pins J2-34/35 are exposed on the panel to facilitate the insertion of a 200 ohm shunt when required. The fixtures rear panel has connectors for the required dual API/Synchro transmitter interface while the panel switches provide the correct routing of each.
-
product
4- Channel PXI Source Measure Unit (SMU)
GX3104
The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.
-
product
PXI-4110, 3-Channel, 20 V, 1 A, 9 W, PXI Programmable Power Supply
779647-10
3-Channel, 20 V, 1 A PXI Programmable Power Supply—The PXI‑4110 is a programmable DC power supply. It is an excellent general-purpose, single-quadrant power supply for design validation and manufacturing test applications. The PXI‑4110 has two isolated and a single non-isolated supply channel, all capable of generating up to 1 A per channel. You can program the voltage setpoint and current limit as well as the voltage and current readback/measurement functionality. You can also combine channels for higher voltage or current.
-
product
Power Supply, 80 V, 65 A, 5,200 W
N8758A
Keysight basic DC power supplies offer essential features for a tight budget. The Keysight N8758A is an 80 V, 65 A, 5,200 W, single-output power supply in a small 2U package. It offers flexible AC input options, analog / resistance control of output voltage and current, and parallel and series connection of multiple supplies to achieve more output current or voltage.
-
product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
product
TriaxM-TriaxM, Low Noise Triaxial to Triaxial Cable for SMUs, 3 m
785659-03
The TriaxM-TriaxM Triaxial Cable connects your system to PXI Source Measure Units and other devices that have a triaxial connector. It uses guarding to remove the effects of leakage current and parasitic capacitance when … measuring very low current signals. The cable offers 300 V DC maximum voltage, 3 A maximum continuous current, 10 A maximum pulsed current, and different lengths.
-
product
Coax, Contact, ITA, 20/26 GHz, Flex 402
610102118
This contact available as a patchcord only. Please select link below to configure a patchcord.Primary mating contact 610102119. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield-SolderInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.25 for 2 - 18 GHz1.30 for 18 - 26 GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications Flex 402 (Only Available in Patchcords)Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ Min.
-
product
64-CH Isolated Digital I/O PCI Cards
PCI-7432/7433/7434
ADLINK's cPCI/PCI-743X series cards are 64-CH high-density digital input and/or output cards that provide a robust 2,500 V isolation protection and are suitable for most industrial applications. The wide input range of the cPCI/PCI-7432 and cPCI/PCI-7433 makes it easy to sense the status of external devices. There are several options for PCI-743X series, such as normal version with input range from 0 to 24 V, as well as HIR version with high input range from 0 to 50 V. The PCI- 7433ALC is specifically designed for AC power test system.
-
product
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
16 Relay Output Board, 8 Isolated Digital Input Channels, 24V
APCI-2200-16-8
16 electromechanical relays with change-over contacts ? Max. switching voltage for the relays: 60 V/DC, 48 V/AC ? Max. switching current: 1 A ? Short response time ? Option: 8 input channels for AC voltage, optically isolated, input voltage range: 12 - 24 V DC ? Watchdog: software-programmable release, stop and time selection.