  • PXIe-5667, 3.6 GHz PXI Vector Signal Analyzer

    782366-03 - NI

    PXIe, 3.6 GHz PXI Vector Signal Analyzer - The PXIe‑5667 is optimized for spectrum monitoring applications such as radio monitoring, interference detection, spectrum regulation, and related applications in line with ITU recommendations. It features real-time signal analysis and advanced signal processing using the capabilities of the built-in FPGA. Additionally, the PXIe‑5667 includes options for various frequency ranges and instantaneous bandwidth.

  • PXIe-5667, PXI Vector Signal Analyzer

    782366-01 - NI

    Up to 7 GHz PXI Vector Signal Analyzer—The PXIe‑5667 is optimized for spectrum monitoring applications such as radio monitoring, interference detection, spectrum regulation, and related applications in line with ITU recommendations. It features real-time signal analysis and advanced signal processing using the capabilities of the built-in FPGA. The PXIe‑5667 includes options for various frequency ranges and instantaneous bandwidth.

  • LISN & Voltage Probes

    Laplace Instruments Ltd.

    All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.

  • SY018 Voltage To Current Converter

    Synectic Electronics

    The SY018 DIN rail Voltage to 4-20mA signal converter is used to communicate analogue signals over long distances where electrical interference may be a problem. This solution is often used in the process control industry to collect the analogue values from a wide array of remote sensors. The converter is valuable because current signals are much less susceptible to noise than voltage signals. A voltage signal can be converted to current and broadcast over a long distance.  4-20 mA transmitters are common in the industry and used with high-quality sensors. The resulting signals can be use in controlling drives or to trigger instruments that have settable thresholds and limits.

  • Vantage PRO2 Davis

    6152 & 6152C - AYA-Instruments

    *Refresh Rate – A packet of data is sent from the outdoor transmitter to the receiver every 2 1/2 seconds! This means when you look out the window and see the wind blowing, the weather station will reflect it almost immediately.*Transmission Distance (wireless models) – The first in its consumer price range to use frequency hopping spread spectrum radio technology, the Vantage Pro2 can transmit and receive data up to 1000′ (300 m) line of sight. This is a much greater distance than most other weather stations. This technology also provides improved reception through multiple walls and greater immunity from RF interference.

  • Impulse Current Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    Impulse current test systems are mainly used for testing transmission and distribution systems against the effects of direct or indirect lightning strokes or against electromagnetic interference effects. Primary application of impulse current test systems is the testing of surge arresters, nowadays mainly of the metal-oxide type (MOA) and surge protection devices (SPD). Now they are also widely used to test vehicles, aircrafts, and military applications.

  • SGMA RF Source

    SGS100A - Rohde & Schwarz GmbH & Co. KG

    The R&S®SGS100A is an RF source designed to meet the requirements of automated test systems. It is available as a CW source or as a vector signal generator with an integrated I/Q modulator. With its frequency range of up to 12.75 GHz, the vector signal generation version covers the essential digital signals. The CW version can be used as a flexible local oscillator and for interference testing against mobile radio standards.

  • Universal PD & EMI analyzer

    Spark P3 - Manta Test Systems

    Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.

  • Impedance Stabilization Network

    Beijing KeHuan Century EMC Technology Co,.LTD

    KH8158 is a device for measuring the common mode interference voltage of unshielded twisted pair cables. Cable testing according to CISPR 16-1-2. The equipment under test (EuT) and auxiliary equipment (AE) are directly connected to the corresponding ports. The port adopts RJ-45 socket (the distribution conforms to T568A/B.) This equipment is divided into three specifications: CAT3, CAT5, and CAT6, and the corresponding equipment is selected according to the cable model.

  • Battery Powered Earth Tester

    GEOHM Series - GMC-I Messtechnik GmbH

    Three or four-pole measuring method1-Clamp Measurement (optional)2-Clamp Measurement (optional)Rechargeable battery operation (optional)Digital displayRobust housingNo balancing requiredContinuous monitoring of interference voltage and auxiliary earth electrode resistance with indication if allowable limit values are violatedData storage for 250 measurements (1000 measured values)Data interface for transmission of measured values to a PCSoftware (optional accessory) for measured value storage at a PC

  • Programmable DC Power Source

    ODP3032 - KILTER ELECTRONIC CO.,LTD

    3.9 inch high resolution ( 480 x 320 pixels) TFT large LCD display,can clear visual display state and a plurality of relevant parametersTwo separate controllable output 0V ~ 30V / 3A,A fixed output 5V / 3A, total output of high power 195WThree channel output and electrical isolation,greatly reduce circuit interference Low ripple and noise of pure power:(<300 uVrms / 2 mVpp)Output resolution :1mV/1mAInternal implementation independent, parallel, series , positive-negative four kinds of work modes and automatic trackingOvercurrent and overvoltage protection function,Can easily set up the overvoltage and overcurrent protection parameters,effectively protect the load

  • 4-20mA Output Inclinometer

    LCF-2330 - Jewell Instruments LLC

    The LCF-2330 inclinometer series now includes a 4-20mA output signal option for applications that require long cable runs. This dual axis tilt sensor is fluid damped to minimize noise and vibration interference while also offering a sharp 1 µradian resolution. An internal temperature sensor is available and dual supply, ± 5 Vdc output is an option. The LCF-2330 is an excellent solution for rugged applications such as radar & antenna leveling, weapons platform leveling, barge and offshore platform control, deviation surveys, 2-axis machine tool leveling, bridge structural monitoring, submersible control feedback, offshore platform stability and manufacturing process equipment for the aerospace industry.

  • Near Field Probes 30 MHz up to 6 GHz

    XF1 set - Langer EMV-Technik GmbH

    The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

  • Capacitive Proximity Sensors

    SICK Sensor Intelligence

    Sometimes you need to know what is hidden beneath a surface. Behind a wall, for example, inside a storage container, inside a shipping container, or behind a cover. Capacitive proximity sensors are ideal for level and feed monitoring. From solid material, such as paper or wood, to granules or liquids, they can be relied upon to detect what is happening in the production process and during final inspection. Is there something behind that cover? Is the finished package really full? How much paint is still left in the tank? For capacitive proximity sensors, these are easy questions to answer. SICKs capacitive proximity sensors are never far from the action. Sensing ranges between 1 and 25 mm allow them to be used in nearly all installation situations, making them extremely adaptable for a wide range of applications. These sensors are also remarkably resistant to interference. Impurities, contamination, dust, and airborne spray particles have little effect on them, nor does electromagnetic interference. No wonder they are installed in a wide range of industries, such as food and automotive, or in storage and conveyor systems.

  • Automatic Capacitance and Tan Delta Bridge

    Eltel Industries

    *Automatic Microprocessor controlled Guarded Bridge Circuit.*Suitable for testing at voltages up to 500kV.*Can be used to measure both Grounded and Un-Grounded Specimens.*Automatic guard circuit for three-terminal measurement.*Interface measurement and automatic interference suppression circuitry.*Optional range Extension Transformer for large capacitance values.*Test data storage facility.*RS-232 computer interface and USB printer interface.*Window Interface Software for data transfer.