Showing results: 16 - 30 of 41 items found.
-
A10160 -
Tabor Electronics Ltd.
Model A10160 is an ultra-small footprint, wideband, DC coupled amplifier designed for high frequency, high current, signal amplification. With a high bandwidth of 45MHz, 34Vp-p into 50 ohms and up to 10W output power, the A10160 is the ideal complimentary amplifier to any signal source that needs a supporting power boost for demanding applications.
-
9100 -
Tabor Electronics Ltd.
Model 9100 is a Single/Dual Channel, 2U, half-rack size, bench-top power amplifier designed for signal amplification. With unprecedented signal purity, Model 9100 amplifies signals from DC to over 500kHz. The unit has a fixed gain of x15 however the same amplifier is available with custom gain and no signal purity or performance degradation whatsoever.
-
9400 -
Tabor Electronics Ltd.
Model 9400 was designed as a general purpose, wide band and high voltage amplifier however, with specific applications in mind. It has four channels built in a small case size to save space and cost but without compromising bandwidth and signal integrity.
-
9200A -
Tabor Electronics Ltd.
Model 9200A was designed as a general purpose, wide band and high voltage amplifier however, with specific applications in mind. It is built in a small case size to save space and cost but without compromising bandwidth and signal integrity.
-
9200 -
Tabor Electronics Ltd.
Model 9200 is a Single/Dual Channel, 2U, half-rack size, bench-top power amplifier designed for signal amplification. With unprecedented signal purity, Model 9200 amplifies signals from DC to over 500kHz. The unit has a fixed gain of x15 however the same amplifier is available with custom gain and no signal purity or performance degradation whatsoever.
-
9100A -
Tabor Electronics Ltd.
Model 9100A was designed as a general purpose, wide band and high voltage amplifier however, with specific applications in mind. It is built in a small case size to save space and cost but without compromising bandwidth and signal integrity.
-
Holding Informtest
Acts as a bridge between a machine, motor controller, or PLC and related drive amplifier, feedback device and/or software.
-
SY018 -
Synectic Electronics
Our compact strain gauge amplifier can be used in applications requiring 4-20mA or a voltage signal from a strain gauge bridge transducer.
-
Type 132 -
Datum Electronics, Ltd.
The Type 132 Amplifier is designed to amplify the signal from any load cell with full bridge connection, allowing the user to use the data from the load cell in a more efficient and productive way.The Type 132 Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor. It can be calibrated to provide a 0-10V output for a fixed load range from the sensor.
-
Type 131 -
Datum Electronics, Ltd.
The Type Load Cell 131 Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor allowing the user to use the data from the load cell in a more efficient and productive way.The Type 131 Load Cell Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor. It can be calibrated to provide a 4-20mA output for a fixed load range from the sensor.
-
WMA-IB-HS -
Falco Systems
The WMA-IB-HS can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision, high speed and low noise. Because of its high bandwidth, the WMA-IB-HS model is ideal for the Falco Systems WMA-100 or WMA-300 amplifiers. It can also be used with all other Falco Systems HV amplifiers, or even with high voltage amplifiers of another brand.
-
WMA-IB-LN -
Falco Systems
The WMA-IB-LN can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision and ultra-low noise. The WMA-IB-LN model has been designed specifically for the Falco Systems WMA-200 high voltage amplifier. Two WMA-200 amplifiers combined with one WMA-IB-LN provide unprecedented noise performance and output voltage range.
-
Datum Electronics, Ltd.
Datum Electronics load cell amplifier range is designed to increase (or amplify) a signal, generated by a strain gauge load cells with a full bridge connection, pressure transducers or torque sensors, allowing the user to use the data from the load cell in a more efficient and productive way.
-
SY038 -
Synectic Electronics
The SY038 is a strain gauge bridge amplifier ideal for use in load cell amplification. This Load Cell Amplifier has a variable gain functionality using a miniature dip switch which enables the user to select one of 16 ranges for transducer outputs as low as 0.25mV/V and up to 4.4mV/V, higher if specified. It has the best stability in its class and high immunity to interference. Non-interactive Zero and Span trimmers are screw driver adjustable giving a further +/-20% adjustment.
-
HS Series -
Load Cell Central
Load cell / scale remote displays are driven from another digital indicator or amplifier. Often used on bridge cranes and truck scales, or in any situation which the person needing to see the scales displayed weight is too far to see the smaller standard indicators. Many styles, digit sizes, indoor and outdoor models are available.