Working Standards
-
Product
The Gold Standard for Breast Screening & Biopsy Training
Mammography QA Solutions
-
When the USA mandated Mammography QA requirements via the Mammography Quality Standards Act (MQSA), medical physicists, the ACR and the FDA worked with Gammex to complete the phantom design known today as the 156 Phantom.
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard Digital Multimeter - Auto Ranging
MM39
-
The MM39 is an auto-ranging multimeter with a large rotary switch for easy selection of the required test, even when wearing gloves. There are two test buttons, one to lock the range and the other to hold the results which are displayed on a 3½ digit LCD screen.
The main test functions are AC voltage and DC voltage and current and resistance. The MM39 measures both AC and DC voltage between 0.1mV to 600V and AC and DC current between 10mA to 10A. There is a diode test and an audible continuity test which sounds at less than 25Ω.
-
Product
Electron Multiplication (EM) Standard Image Sensors
-
EM (Electron Multiplication) is a technology that uses on-chip gain in the charge domain to effectively eliminate read noise from an image sensor. This enables advanced ultra-low light applications that require extreme sensitivity at fast frame rates. Examples include life science applications such as single molecule detection, super resolution microscopy and spinning disk confocal microscopy along with physical science applications such as nanotechnology imaging, Bose Einstein condensates and soft X-ray spectroscopy, and astronomy applications such as adaptive optics and lucky imaging. The inclusion of an additional conventional output allows further flexibility for applications such as true 24 hour surveillance.
-
Product
Open Network Standards
ControlNet
-
ControlNet is one of three open network standards (DeviceNet, ControlNet and EtherNet/IP), all of which use a common application layer, the "Common Industrial Protocol" (CIP). The Family of CIP Networks is specified and published by ODVA (Open DeviceNet Vendor Association - http://www.odva.org) and CI (ControlNet International - http://www.controlnet.org).
-
Product
Capacitance Standard
SCA Series
-
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
Product
Standards and Regulations
-
Is your organization ready to engage in the world of autonomous and electric vehicles?
-
Product
Industry Standard in Noise Measurement
PN9000
-
The PN9000 is a simple and fast Automatic Phase Noise Test System covering a very wide frequency range(2 MHz to 140 GHz). Its modular architecture allows optimum configuration, multiple measurement techniques and future growth in a compact instrument.
-
Product
Four Terminal Pair Standard Resistor Set
42030A
Programmable Resistor Module
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Solution Standard Reference Materials
-
NCS Testing Technology Co., Ltd.
Solution Standard Reference Materials by NCS
-
Product
Capacitance Standard
GenRad 1417
-
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
Product
Gas Flow Standards
-
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Standard Pattern Generator Board
BL-PG315-01
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
Standard Type Externally Modulated Optical Transmitter
HT8500H
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1550nm externally modulated optical transmitter is the core equipment in the RFTV network system.RFTV is a unidirectional analogue and digital video broadcast. It adopts high efficiency modulation mode for RF carrier wave and its economy , flexibility and bandwidth validity is beyond comparison of IPTV. By adopting EPON, GEPON or P2P access mode to realize triple-play and FTTx, RFTV broadcasting network in 1550nm optical wavelength still plays an important role.
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2TB-8
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.88 (24.90) - 4.50 (128.00) Switch Probe
SSP-5C
Switch Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Spring Force Remark: Force at switch point: 2.36 (66)Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 150Full Travel (mm): 3.81Recommended Travel (mil): 100Recommended Travel (mm): 2.54Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,210Overall Length (mm): 30.73Switch Point (mil): 25Switch Point (mm): 0.64
-
Product
Standard Loggers
-
Our standard loggers can measure up to 13 parameters. Numerous configuration options allow for maximum customization for your measurement needs. In addition to our conductivity, temperature and depth sensors, many others, including third-party sensors, can be used with our recorders. Measure salinity. Measure tide and waves. Altitude & Attitude Logger.
-
Product
Standard Mass Flow Meter
Series II
-
Offers outstanding value in a wide range of industrial and lab applications. Exceptional accuracy and repeatability with flow ranges from 0.014 cc/min up to 1670 l/min. and working pressures up to 6000 PSIA. Offers multi-gas and multi-range capability
-
Product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2TB-6
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HL-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Sematech Analysis and SEMI Standards Analysis
-
Rocky Mountain Laboratories, Inc.
Rocky Mountain Laboratories, Inc. provides SEMI Standards analyses that conform to the following SEMATECH and SEMI Standards for testing of passivated 316L stainless steel components being considered for installation into a high-purity gas distribution system:SEMASPEC #90120401B-STD (SEM Analysis)SEMASPEC #90120402B-STD (EDS Analysis)SEMASPEC #90120403B-STD (XPS Analysis)SEMASPEC #91060573B-STD (Auger (AES) Analysis)SEMI F60-0306 (based on F60-0301) (XPS Analysis)SEMI F72-1102 (Auger (AES) Analysis)
-
Product
NF-Series Standard Plus Models
-
The E-DRIV® NF-Series standard plus models feature a selectable Double Hit Mode for soft joint applications and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-FK180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2LB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensationof power factor in low voltage instalations.
-
Product
Comprehensive Standard Software
Halicon
-
MVTec HALCON is the comprehensive standard software for machine vision with an integrated development environment (HDevelop) that is used worldwide. It enables cost savings and improved time to market. HALCON’s flexible architecture facilitates rapid development of any kind of machine vision application. HALCON provides you with continuous access to the latest technologies to solve machine vision applications. Find out more about the different editions and their release cycle.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1G
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64





























