Filter Results By:

Products

Applications

Manufacturers

Showing results: 736 - 750 of 831 items found.

  • Cable Continuity Tester, VGA/UL2919 Mini, Network, 21.01 mm, 35 mm, 45.01 mm

    72-9205 - Tenma

    Quickly test VGA / UL2919 cables No need to carry bulky, expensive cable testers to test only one or two cable types Mini cable tester fits easily in your pocket or tool box, and requires no external power Confirms conductor continuity with sequential LED's Save time and money by diagnosing connectivity issues All units are powered by a cross compatible 3xAA battery pack or USB cable (both included) Most units measure 2" x 2" x 1" or less!

  • Aircraft Escape Systems

    Teledyne Defense Electronics

    The Emergency Interseat Sequencing System (EISS) was designed an qualified for the F-15K Fighter and has since been installed in the F-15SG and F-15SA configurations of the F-15. The system consists of Thermal Batteries with Initiators, a Digital Interseat Sequencer, Mode Selector, and customer provided cabling Electro-Explosive Devices (EEDs). The system is operated from either thermal battery and aircraft 28Vdc for redundancy. A separate field Test Set (EESSTS) performs both complete system continuity tests and an operational test of the total system installed in the aircraft. The sequencer is programmable and could be used in any escape system.Based on the initiation point, Forward or Aft Seat Handle, Internal or External Canopy Jettison Handles, and the Mode Selector setting, the Sequencer provides firing pulses to the EEDs to support canopy removal, ejection seat inertial reel activation(s) and ejection seat catapult firing(s). Sensing capabilities are provided to determine system state, canopy gone, seat gone, so as to provide the optimum escape timing.

  • Portable Fuel Dilution Meter

    FDM 6000 - Ametek Spectro Scientific

    The FDM 6000 is a portable, battery operated fuel dilution meter that determines the concentration of fuel dilution present in an oil sample within a matter of minutes. The FDM 6000 uses a unique patent pending fang design to pierce the cap of a disposable sample vial and draws in the headspace from the vial. The headspace flows over a SAW (Surface Acoustic Wave) sensor which reacts specifically to the presence of fuel vapor with a detection range of 0 – 15%. It can detect diesel, gasoline or jet fuel in engine oil. It conforms to ASTM D8004 - "Standard Test Method for Fuel Dilution of In-Service Lubricants Using Surface Acoustic Wave Sensing"

  • PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module

    778572-14 - NI

    7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module

    778572-12 - NI

    7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module

    778572-10 - NI

    68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • Digital AC/DC Auto-Ranging Clamp Meter

    PCMT20 - Pyle Audio Inc.

    Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit

  • Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL - Tenma

    The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench Digital Multimeter, Calibrated, Data, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL D - Tenma

    The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL DU - Tenma

    The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • 2-port Battery Portable Passive Intermodulation Analyzer - iXA Series

    iXA - Kaelus

    The Kaelus iXA Series Passive Intermodulation (PIM) analyzer is a dual-port, battery powered PIM Test Analyzer. It supports multiple test scenarios such as testing at the top of the tower, the base of the tower, rooftop, in-building for DAS systems and external PIM Finding.No other PIM tester has ever been integrated to this level! The iXA includes a network of electronic switches to change from one-port to two-port measurement seamlessly. In addition, with integrated Range-to-Fault (RTF) on each port, the user can first troubleshoot the system for internal PIM. Then, without reconnection, the user can progress with the external PIM process, making the entire process much more efficient.With integrated RTF on each port, the user can collect four times more range-to-fault data than the standard 1-port PIM Finder solution. Thus, the user can easily locate and swiftly eliminate the strongest PIM source.

  • True RMS Digital Multimeter

    72-10415. - Tenma

    *Handheld digital multimeter*Measure AC/DC voltage, AC/DC current, resistance, frequency and capacitance*Diode test and continuity buzzer*Manual function select & auto ranging*Data hold function*Auto power off, low battery indication*Input impedance for DC voltage around 10Mohm*MAX / MIN / Relative Modes*Analog Bar Graph*CAT III 1000V, CAT IV 600V rated

  • DC Power Supply

    62000H - Chroma Systems Solutions, Inc.

    Chroma’s new 62000H Series of programmable DC Power Supplies offer many unique advantages for telecom, automated test system & integration, industrial, battery charge & simulation for hybrid cars and solar panel simulation. These advantages include a high power density of 15KW in 3U, precision readback of output current and voltage, output trigger signals, as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations. For high power applications, parallel up to 10 units for up to 150kW.

  • Ultrasonic Flaw Detector

    MFD350B - Mitech Co., LTD.

    Based on ultrasonic principle, digital ultrasonic flaw detector MFD350B with 320*240 TFT LCD, it can test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in workpiece’s interior swiftly and accurately without any destruction. It can be used in Laboratory as well as in engineering filed. With range of 0-6000mm, it can meet the requirement for general defect inspection in manufacturing industry, metallurgical industry, metal processing industry, chemical industry and so on. Low power design with large capacity and high performance lithium battery module, it can be long standby for months. High quality with low price, it is the first choice for the practical economic model for ultrasonic testing equipment.

  • Ultrasonic Flaw Detector

    MFD500B - Mitech Co., LTD.

    Based on ultrasonic principle, digital ultrasonic flaw detector MFD500B with 320*240 TFT LCD, it can test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in workpiece’s interior swiftly and accurately without any destruction. It can be used in Laboratory as well as in engineering filed. With range of 0-9999mm, it can meet the requirement for general defect inspection in manufacturing industry, metallurgical industry, metal processing industry, chemical industry and so on. Low power design with large capacity and high performance lithium battery module, it can be long standby for months. High quality with low price, it is the first choice for the practical economic model for ultrasonic testing equipment.

Get Help