Showing results: 421 - 435 of 1134 items found.
-
SL-180C -
JFE Advantech Co., Ltd.
For waste water and sewage water facilities: Pumping stations, Flow conduits in treatment plants and so on.
-
-
Sefram
Environmental testers sample and measure environmental elements such as temperature, humidity, sound, pH & air flow.
-
C2000 -
Webster Instruments
Measure hydraulic flow, pressure, temperature, speed, current (Amps), contamination and other custom inputs.
-
KATflow 150 -
Katronic
The KATflow 150 is the premier product for flexibility and performance, providing the user with a comprehensive specification and a list of configuration options. The practical modular design and the wide variety of different transducer types available ensure this instrument is suitable for everything from simple water flow measurements to energy flow monitoring and automated process control.
-
Wewon Environmental Chambers Co, Ltd.
Automated Test Equipment (ATE) adopts PID+PWM principle VRF (Refrigerant flow control) technology to realize low temperature and energy saving operation (servo control technology of refrigerant flow based on thermal condition of electronic expansion valve). Realize the automatic constant temperature of the studio.https://www.wewontech.com/automatic-test-equipment/
-
DVS Resolution -
Surface Measurement Systems
DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.
-
Titan Enterprises Ltd
Titan’s small turbine flowmeter range use a radial flow principle based on the Pelton wheel technique. This well proven method is the ideal way of measuring low rates of flow of low viscosity liquids. For these mini flowmeters, a jet of fluid is directed at a turbine that is mounted on robust low friction sapphire bearings. The geometry of the turbine and the fluid chamber ensures that the rotational speed of the rotor is proportional to the flow rate through the device. The use of this radial arrangement allows more energy to be imparted into the turbine, so the bearing drag is far less important. Furthermore, because more energy is available the bearings themselves can be a lot stronger so increasing the life of the flowmeter. For larger flows, some of the liquid can bypass the turbine chamber, which then behaves as a “shunt” to the metered fluid. Accuracy is still maintained and the output remains linear.
-
3054A -
TSI Inc.
The Model 3054A Aerosol Neutralizer has twice the activity of the Model 3054. It neutralizes highly charged, high concentration aerosols at flow rates up to 150 L/min. It is intended for use with TSI Model 3450 Vibrating Orifice Aerosol Generators.Features and Benefits Radioactivity of 740 MBq Maximum flow rate of 150 L/min
-
DOLPHIN Design
Today, Dolphin Integration's EDA Solutions can be used as:*The front-end design solution of choice, for any custom design flow, coupled with third-party back-end solutions. Such a setup is ideal for small to medium size companies who target using affordable state-of-the-art design solutions with no compromises on performances or innovation.*Point-products to complement existing design flows as Missing EDA Links for specific needs. Such an approach is ideal for companies with corporate agreements for full CAD flows from major vendors who wish to benefit from the innovations of our EDA solutions.
-
EG-100 -
HORIBA, Ltd.
Washwater Monitoring System for NOx and SOx Scrubber.Monitoring pH/Temperature, Turbidity, and PAH.EG-100 has flow type sensors.
-
VSO®-EP -
Parker Hannifin Corp.
Parker’s VSO- Electronic pressure control unit is specifically designed for precision gas and microfluidic flow control
-
KROHNE Messtechnik GmbH
OPTITEMP smart compact sensors for temperature measurement in gases and liquids, in pipes and tanks at medium pressure and flow
-
Dantec Dynamics A/S
Planar laser-induced fluorescence (PLIF) is an optical diagnostic technique widely used in fluid and gas applications. PLIF has proven to be a valuable tool for flow visualization as well as for quantitative whole-field measurements of scalars such as concentration and temperature in liquid and concentration in gaseous flows. Applications can be found in process engineering, biomedical engineering, and fluid dynamics research.
-
PV Series -
HORIBA, Ltd.
The Piezo Actuator Valve PV Series consists of piezo actuator valves with metal diaphragms and metal O-rings. When combined with a pressure sensor or flow rate sensor and ratio control unit (PCU series) you can use the Piezo Actuator Valve PV Series to create a pressure control or flow rate control system.