IEPE
standard for accelerometers.
-
Product
IEPE Signal Conditioning Amplifiers
-
Although IEPE (Integrated Electronics Piezoelectric) sensors is not a new technology there are a wide variety of applications where the measurement instrumentation is not configured with IEPE signal conditioning built in. In these situations it is necessary for the IEPE supply to be provided by an external source. Usually this type of instrument will also provide th user with the option to add gain to the signal being conditioned. The Kemo range of IEPE signal conditioning instruments can be used as stand alone conditioners/amplifiers are many of them can also be integrated with filters.
-
Product
Digital USB Sensor Interface AC,DC, IEPE
ROGADAQ2
-
The RogaDAQ2 USB DAQ is developed for highly accurate measurements in the T&M and also for NVH measurements. This USB Front End is optimized for noise and vibration measurements with 2 channel IEPE (ICP®) sensor supply.
-
Product
PCB TA01, 5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor
780990-01
-
5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor - The PCB TA01 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB TA01 features a sensitivity range of 5 mV/g.
-
Product
IEPE Monoaxial Accelerometer – 100 mV/g
HDP352C34
-
Monoaxial accelerometer general purpose, ICP, 100mV/g, weight 5,8 g, range 50 g pk
-
Product
Easy Connection Of IEPE Sensors To Voltage Input Measurement Devices
K- IEPE
-
Our K-IEPE module is designed to connect IEPE sensors to a voltage measurement device that normally cannot support IEPE sensors. The powered K-IEPE module simply enables IEPE sensors to be connected via the BNC terminals and will output the signal voltages to an analog measurement device.
-
Product
PCB GPTC03, 10 mV/g, IEPE, Accelerometer, General-Purpose Vibration Sensor
780988-01
-
The PCB GPTC03 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the … Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB GPTC03 features a sensitivity range of 10 mV/g and requires a low-noise coaxial cable.
-
Product
IEPE Triaxial Whole Body Accelerometer – 1000 mV/g
HD2030MSP
-
HD2030MSP is an accelerometer suitable for the measurement of vibrations transmitted by seats to the occupants of passenger and work vehicles.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
-
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
Product
IEPE Triaxial Accelerometer – 1000 mV/g
HDP356B18
-
Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk
-
Product
External Powered IEPE Signal Conditioner
ADAM-3017
-
IEPE current support: 4, 6, 10 mAExternal powered operation eliminates line noiseLED indicator for sensor open, short and normal
-
Product
IEPE Triaxial Accelerometer – 10 mV/g
HDP356A02
-
Triaxial accelerometer miniature for hand-arm measurement, ICP, 10mV/g, weight 4g, range 500 g pk
-
Product
IEPE Triaxial Accelerometer – 1000 mV/g
HDWBV-100
-
IEPE tri-axial accelerometer for the measurement of vibration transmitted to whole body.
-
Product
PCB GPTA02, 10 mV/g, IEPE, 1 Hz to 5 kHz, Accelerometer, Triaxial Vibration Sensor
784169-01
-
The PCB GPTA02 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB GPTA02 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
Product
IEPE Impact Hammers
-
Our range of general purpose IEPE impact hammers offer a range of great cost effective solutions for a majority of applications requiring the excitation of a structure. The most common application being Modal testing whereby the structure is excited using the impact hammer and the response of the structure is measured using accelerometers. However instrumented hammers can also be used for crack detection and other structure related investigations.
-
Product
128 KS/s, 24-Bit, 8-Ch PCIE Card For IEPE Sound And Vibration
PCIE-1803
Sound and Vibration
8 simultaneously sampled analog inputs, up to 128 kS/s24-bit resolution ADCs with -102 dB total harmonic distortion plus noise (THD+N)
-
Product
C Series Sound And Vibration Input Module
Sound and Vibration
The C Series Sound and Vibration Input Module incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. The modules are compatible with smart TEDS sensors.The C Series Sound and Vibration Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
Transducer Calibration
m+p SensCal
-
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.
-
Product
PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module
781370-01
Analog Input Module
204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
Signal Conditioning System
28000
-
The Precision 28000 Signal Conditioning System makes it easy to manage a test with up to 256 channels of fully programmable transducer conditioning. Choose a mix of bridge, charge, IEPE w/TEDS, voltage (filter amplifier), strain, thermocouple, RTD/potentiometer, frequency, or other transducers. Self-tests traceable to NIST. 4, 8 and 16-slot rugged and transportable mainframes feature integrated cooling. Customize the 28000 for high-speed transient applications, static applications, or a combination of both.
-
Product
Amplifier
AC-100
-
The voltage amplifier for connecting piezoelectric acceleration meters, microphones, and other primary voltage output transducers to FFT spectrum analyzers with the IEPE standard current output (ZET 017-U2, ZET 017-U8, A19-U2).
-
Product
MINITAURs - 8-channel universal DAQ system
MINITAUR-S
-
Mixed signal 8-channel data acquisition system and multichannel data logger with cutting-edge technology at an attractive price. Universal analog inputs can accommodate various signals like strain gage, IEPE, voltage, current, RTD, thermocouple, and LVDT.
-
Product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
Analog Input Module
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
Impulse Hammers/Impedance Heads
-
Impulse hammer excite from the smallest of structures to various civil engineering structures. The Dytran model 5800SL is an ultra miniature IEPE impulse hammer used to excite structures or machinery with a definable impulse force in modal and structural analysis of very light structures and impulse testing of very low mass, high resonant frequency components.
-
Product
PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device
779309-01
Sound and Vibration
The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
Product
Special Accelerometers
-
Metra Meß- und Frequenztechnik Radebeul GmbH & Co. KG
This page shows vibration sensors for special applications.The Seat Pad Accelerometer Model KS963B100-S was developed for measuring whole body vibration transmitted by driver seats of building machines and other vehicles in compliance with ISO 10326-1 and ISO 7096. The sensor has an IEPE output for robust signal transmission.
-
Product
PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module
784277-01
Analog Input Module
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.
-
Product
PCB Triaxial Accelerometer, 1000mV/g, ICP®(IEPE), 0.5Hz-3kHz
784815-01
-
The PCB Miniature Triaxial Accelerometer helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB Miniature Triaxial Accelerometer features a sensitivity range of 1000 mV/g and requires the PCB lightweight cable with 4-socket plugs.
-
Product
PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device
779307-01
Sound and Vibration
The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
Product
8-CH 24-Bit High-Resolution Dynamic Signal Acquisition Module
PCIe-9529
Analog Input Module
The ADLINK PCIe/PXIe-9529 is a high-performance, high density, 8-CH analog input dynamic signal acquisition module. The PCIe/PXIe-9529 features eight 24-bit simultaneously sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate of 192 kS/s at high resolution, making it ideal for higher dynamic range signal measurement. All channels are sampled simultaneously and accept input range up to ±10V, and the analog inputs support software-selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors. The module is especially designed to meet the requirements of vibration analysis and audio testing.
-
Product
USB-4431, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device
780164-01
Sound and Vibration
The USB-4431 is designed for sound and vibration measurements. Input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. The four USB-4431 input channels simultaneously digitize input signals. The analog output (AO) channel is ideal for stimulus-response tests and can be synchronized to the AI channels.