- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Matrix Module, 6x8, 2-Pole, Y Loop-thru
40-514-001
The 40-514-001 (PXI) and 42-514-001 (PXIe) are low density matrices in 6x8 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.
-
product
NI-9470, 5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module
787089-01
5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module - The NI‑9470 is a digital output module that features proportional valve drive control. You can use the NI-9470 to perform pulse width modulation (PWM), dither control, and current readback. The NI‑9470 features eight output channels compatible with signals from 5 V to 30 V and transient overvoltage protection between the output channels and the backplane.
-
product
Electronic Multifunction Data Loggers
The DeltaTrak Electronic Data Logger is a portable, pocket sized electronic device powered by a 10-year lithium battery. It is designed for easy and reliable tracking of parameters such as temperature, relative humidity, electric current, pressure, process signals, and pulse signals. All data loggers have a built-in temperature sensor plus single or multiple external channels where different sensors can be attached for remote monitoring of a variety of parameters. The DeltaTrak Data Loggers inte...show more -
product
High Current SMU 1000 A
AXC7583
Generate extremely short, fully regulated current pulses from 300 µs up to 1000 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.ven Bauteilen.
-
product
Lightning Surge Generator
SKS-0506IB
Shanghai Sanki Electronic Industries Co., Ltd.
The lightning surge generator SKS-0506IB1 fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; provides a pulse test voltage of up to 6kV; both AC and DC samples can be tested , subject to The rated voltage of the test equipment can reach 400V, and the rated current of the three-phase equipment is higher than 32A; 7-inch color LCD touch screen, friendly human-computer interaction interface, more intelligent and more user- friendly operation; the software is built in the IEC standard Level mode can be directly called.
-
product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and ...show more -
product
Programmable DC Electronic Load
Four parameters, highlight VFD display.Resolution of voltage and current: 0.1mV/0.1mA.Four working modes: CV/CC/CR/CP.Three dynamic test function (up to 10KHz): continuous load switching mode, pulse load mode, toggle load switching mode.Ten groups automatic testing data files with each file 10 steps.Intelligent fan cooling, coding switch, built-in buzzer, non-slip feet .Complex current sequence list test mode .Remote sensing function.Battery discharging test mode.All modes turn on default
-
product
Instrument Mainframe
PI-11006
The PI-11006 Instrument Chassis was designed to accommodate the power and noise requirements of some of Pulse Instruments analog instrument cards. These instrument cards, such as the PI-41401, PI-41702 and others supply signal outputs that require more current from the -12 V supply than available in a standard chassis. Therefore this chassis has a larger -12 V power supply that provides 2.5 Amps.
-
product
JESD22-A115 Machine-Model (MM) Pulse Emulator
MM-10A
High Power Pulse Instruments GmbH
- Pulse unit to generate JESD22-A115 machine-model (MM) waveforms with TLP- Extremely stable and reproducible machine-model (MM) waveforms- Compatible with HPPI TLP-3010C/4010C/8010A/8010Csystems which have installed pulse width of 25 ns and rise time of 100 ps to 300 ps- Up to ±10 A machine-model peak current with TLP-3010C, which is equivalent to ±667 V (MM)- Up to ±15 A machine-model peak current with TLP-4010C, which is equivalent to ±1000 V (MM)- Up to ±30 A machine-model peak current with ...show more -
product
500A, 5 MHz CURRENT PROBE, BNC, AC/DC, 500A rms, 750A Peak Pulse
T3CP500-5
500A, 5 MHz CURRENT PROBE, BNC, AC/DC, 500A rms, 750A Peak Pulse.
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010C
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger ou...show more -
product
High Voltage 50 Ω Pulse Generator
TLP-12010A
High Power Pulse Instruments GmbH
- High pulse output current up to ±120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical 300 ps rise time- Wafer, package and system level TLP and HMM testing- 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 digital programmable pulse rise times out of: 300 ps to 50 ns (optional)- 1 built-in pulse width: 100 ns- Optional external p...show more -
product
Power Cable Fault Locator
TM500
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
product
Digital Current Integrator
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure DC currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.
-
product
Split type Pulse Current Sensor
CTF-05M
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Through hole type CT.*Open collector output.
-
product
*High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100k...show more -
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is ...show more -
product
SpikeSafe DC / Continuous Pulsed Current Sources
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
product
LXI Dual 75x4 2-Pole HV Matrix
60-311-002
The 60-311 is a 2-pole Matrix Module available with one, two or three separate 75x4 matrices housed in the same case. It is capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle.
-
product
Coupling Decoupling Network for Communication Lines
CDN61000-5C
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of line...show more -
product
Incremental Encoders
Versatile, compact and flexible – Incremental encodersIncremental encoders are used when retention of absolute position upon power loss is not required. These encoders provide information about the position, angle and number of revolutions. The number of lines per revolution determines the resolution. The current position can be determined by counting these pulses from a reference point. Upon activating the machine, a reference run to the reference point is required to determine the absolute position of the encoder.
-
product
Diode Driver & Laser System Controllers
The laser controllers provide a simple method of controlling Lumina and other popular laser diode drivers or full laser systems. They include the ability to easily control current levels, pulse modes, and interlock controls as well as monitor voltage and current levels as well as q-switch triggering, external triggering, sync output, and additional I/O signals.
-
product
Diode Laser Driver
D200
The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.
-
product
Floating 6-Ch Integrated Power Source
PM0650
The pulse channels provide voltage pulses with duration control 10us to 100ms, and measures current. The combination of capabilities provides a versatile solution on fulfilling the wide range of requirements on testing a device. The PM0650 may be floated up to ±1500V to facilitate HV isolation test of devices where outputs may be connected directly to line voltages.
-
product
Magnetizer
U-Serie
MAGNET-PHYSIK Dr. Steingroever GmbH
The pulse magnetizers of the U series are suitable for a wide range of applications in the laboratory and in production. With low energies, they are ideally suited for sensor systems made of ferrite material, which can be magnetized with short cycle times at currents of up to 20 kA. In the energy classes 1,400 Ws and 2,800 Ws, rotors with NdFeB magnets up to a diameter of approx. 60mm are typical applications. With this device, you can magnetize with pulse currents of up to 60 kA.
-
product
Split type Pulse Current Sensor
PCT-06
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
product
IC Side Channel Analysis
These probes allow you to couple fast, transient magnetic field, E-field, and current pulses into ICs.
-
product
PWM Type AC Power Supply
LSP-5KVA
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Eff...show more -
product
SparkFun Coulomb Counter Breakout
LTC4150
Odometers are extremely useful for cars, they tell you how far you have gone, wouldn't it be nice if you were able to have a device that does the same for electrical current? The LTC4150 SparkFun Coulomb Counter Breakout is here to be your odometer for current. If you are wondering: a coulomb is defined as, to put it simply, one amp for one second. This breakout is capable of constantly monitoring the current your sensor is using, is able to add it up, and will give you a pulse each time a given amount of amp-hours have been used. When used effectively and if you start with a full battery, you’ll always know exactly how much of it is left!
-
product
Medium & High Voltage Pulse Generators (Rise Time > 1 ns)
Offer fast medium voltage pulsing with high current capability. These models are ideal for driving solenoids, pulse testing of MOSFETs, and other applications.