Filter Results By:

Products

Applications

Manufacturers

Spectrometers

Measure the wavelengths and intensity of light.

See Also: FTIR Spectrometers, THz Spectrometers, HPGe, Spectrograph


Showing results: 451 - 465 of 505 items found.

  • Benchtop NMR System

    Spinsolve - Magritek

    The Spinsolve Autosampler uses a rotating carousel and mechanical arm to introduce and remove samples from the spectrometer. It enables up 20 separate samples to be measured in any order and can be fitted to all Spinsolve models. The software is very easy and intuitive to operate and requires very little training to use. It useful for customers who often have a series of samples to run on their benchtop NMR and want to save the hassle of having to keep coming back to exchange samples. Another benefit is the ability to increase utilization by setting up a queue of experiments to run on their Spinsolve overnight.

  • Forensic Products

    ScienceGL, Inc.

    During 6 years of R&D, original 4D hyper-spectrum data processor software was developed. Based on Hyper-spectrum image stack processing the software is optimized for specific document examining tasks. The program is designed to process data from Hyper-spectral imaging equipment. It was successfully implemented in our partner product ForensicXP automatic full digital hyper-imaging spectrograph. The original patent pending method was developed for spectral signature unwrapping and enhancement of spectrometer output. An exceptional sensitivity of the instrument and broad spectral range permits to detect very small differences in similar inks.

  • Reflection/Transmission Test Chamber

    CHTR-100 - Lisun Electronics Inc.

    When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.

  • Miniature Single-Stage Isolators – 780nm And 852nm

    AOSense

    AOSense is excited to offer free-space optical isolators at 780 nm and 852 nm. The innovative, small package size enables integration into compact laser sources and amplifiers without sacrificing transmission efficiency. The low external magnetic field enables the isolator to tightly integrate into systems with high magnetic-field sensitivity such as atomic spectrometers, magnetometers, clocks, and cold-atom devices.

  • CWDM Power Meter

    OCC-50 - ShinewayTech

    OCC-50 Handheld CWDM Optical Channel Checker is specially designed for CWDM installation, maintenance and troubleshooting, which is able to measure and monitor power values of up to 18 CWDM channels. OCC-50 can replace high-cost spectrometers and conduct quick and reliable measurements in all environments. Thanks for its light, compact and sturdy design, OCC-50 is the ideal tool for CWDM installation and maintenance technicians.

  • Charge Sensitive Preamplifier-Discriminator

    A101 - Amptek Inc.

    Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.

  • Miniature Dual-Stage Isolators

    780nm And 852nm - AOSense

    AOSense offers dual-stage, free-space optical isolators at 780 nm and 852 nm for enhanced isolation. The innovative, small package size enables integration into compact laser sources and amplifiers without sacrificing transmission efficiency. The low external magnetic field enables the isolator to tightly integrate into systems with high magnetic-field sensitivity such as atomic spectrometers, magnetometers, clocks, and cold-atom devices.

  • Non-Destructive Subsurface Layer Profiling

    NMR-Mouse one-sided NMR - Magritek

    The unique, powerful Profile NMR-MOUSE® probe works hand-in-hand with the Kea2 spectrometer. The Profile NMR-MOUSE is a portable, open NMR sensor equipped with a novel permanent magnet geometry that generates a flat sensitive volume parallel to the scanner surface. The system can measure *Proton density as a function of depth *T2 NMR relaxation times *T1 NMR relaxation times *Self-Diffusion coefficient of liquids

  • Streak Cameras

    Optronis GmbH

    Streak camera technology was developed for measuring ultra-fast optical phenomena. OptoScope streak cameras provide temporal resolution down to the Picosecond regime. Additionally, OptoScope systems have high sensitivity allowing single photon detection. Streak cameras are the only instruments that can capture the behavior over time of multiple optical signals. Combined with a spectrometer this allows their application in the field of time resolved spectroscopy.

  • Ultrafast Laser Pulse Measurement System

    FROG Scan Ultra - MesaPhotonics, LLC

    With a slightly larger format than our high value FROG Scan system, our FROG Scan Ultra platform allows any Ocean Optics spectrometer to be used (including the QE65000 and InGaAs models). This means higher resolution and the availability of InGaAs detectors for your ultrafast laser system. It can measure pulses from nearly 4 ms (custom systems only) to as short as 450 nm.

  • Gasmet Portable FTIR Ambient Gas Analyser

    DX4030 - Quantitech Limited

    The Gasmet DX4030 was the first truly portable FTIR gas analyzer in the world. The lightweight analyzer module is located in durable Teflon–coated backpack. The DX4030 analyser module houses a Fourier Transform Infrared (FTIR) spectrometer, Rhodium-Gold coated sample cell and signal processing electronics. The sample gas is extracted into the sample cell via a probe with built in a particle filter. Hence no sample preparation is needed.

  • Ionization Sources

    BaySpec, Inc.

    BaySpec offers many types of ionization sources to use with our Portability™ and Continuity™ portable mass spectrometers. Delivering ultimate mobility and ease of use, BaySpec’s Portability™ and Continuity™ are compatible with ambient ionization techniques, which do not require any gases or tanks to run measurements. Making it ideal for field analysis, ambient ionization does not require sample preparation; sample introduction quick, direct, and easy to perform by anyone in any location. Providing flexibility to perform applications using various ionization techniques, the external ionization sources can also easily be swapped in less than a minute.

  • Device Test Kits

    Hach Lange GmbH

    Instrument test kits are based on either the multi-parameter DR 900 handheld colorimeter or the Hach DR 1900 handheld spectrometer. Select kits also include the Hach digital titrator, POCKET PRO pH tester and/or HQ40D meter (dissolved oxygen, conductivity, ORP, etc.). Instrument sets are useful for a wide range of applications including potable water, waste water and industrial applications such as boilers and chillers.

  • Color Card Winder

    TY390 - TESTEX Testing Equipment Systems Ltd.

    Color Card Winder is specially designed to wind cards for Textile Industry. The machine is used for making color cards, which will be fed into the photo spectrometer of the computer color matching systems. The machine is also fitted with electronic counters for pre turn settings.It is especially suitable for the following purposes:Sample cards, whiteness test, ultraviolet ray resist test, sample standardization, color comparison, color chart etc.

  • Engine Exhaust Particle Sizer

    Spectrometer 3090 - TSI Inc.

    The Engine Exhaust Particle Sizer 3090 (EEPS™) spectrometer measures the size distribution of engine-exhaust particle emissions in the range from 5.6 to 560 nm with the fastest time resolution available. Users can visualize and study the dynamic behavior of particle emissions that occur during transient test cycles, during the first few seconds of a cold start, or during regeneration of a particle trap or diesel particulate filter (DPF).

Get Help