Battery Impedance
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, 1 kV Isolation
43-752A-111
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXIe Battery Simulator Module, 4-Channel, 5 Amp
43-754-011
The 41-754-011 and 43-754-011 are 4 channel battery simulators, capable of supplying up to 8 V and 5 A per channel. The channels are fully isolated from ground and from each other allowing series connection to simulate batteries in a stacked architecture. The isolation barrier (1000 V channel to GND and 750 V channel to channel) allows the module to be used as a battery stack representative of those used for vehicle propulsion..
-
product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4T
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
product
BIP-3 Battery Probes
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2LB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
AC / DC Current Probe, 2 MHz, 500 Arms
N2780B
The N2780B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 500 Arms continuous.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, 1 kV Isolation
41-752A-111
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI/PXIe Battery Simulator Module, 4-Channel, Simplified Current Sink, 750 V Isolation
41-752A-902
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI/PXIe Battery Simulator Module, 2-Channel, V/I Readback, 1 kV Isolation
41-752A-113
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
CP-2XX-8 Battery Probes
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, Simplified Current Sink, 750 V Isolation
43-752A-901
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2SB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
41-752A-911
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Impedance Analysis
S96041B
Make impedance analysis measurements of Surface Mount Device (SMD) components on the E5080B vector network analyzer with 16198A-010 10 GHz SMD test fixture.
-
product
Impedance Analyzers
HTF-1100.
A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.
-
product
Battery Simulator
The battery simulator is used for testing satellite power supplies and is used in combination with a Solar Array Simulator and load systems (consumer simulation) for the validation and commissioning of satellite power supplies. Loads and power supplies in the battery simulator are operated in combination to represent a 2-square function and to simulate both charging and discharging of the battery.
-
product
Impedance Analyzer
1260A
The model 1260A Impedance/Gain-Phase Analyzer is - without doubt - the most powerful, accurate and flexible Frequency Response Analyzer available today. In daily use by leading researchers wherever measurement integrity and experimental reliability are of paramount importance, the 1260A’s solid reputation is frequently endorsed in published research papers in fields.
-
product
Precision Impedance Analyzers
6500B Series
Accurate high frequency measurements combined with an easy to use graphical interface and high resolution colour display.
-
product
PXI/PXIe Battery Simulator Module, 2-Channel, 750 V Isolation
43-752A-003
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Precision Impedance Analyzer
TH2851-030
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-30MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration
-
product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz • SWR
-
product
High Impedance Probes
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
product
Impedance Matching Pads
These impedance matching pads are resistive networks that can be used to match 2 devices with different nominal impedances. The resistive network used in these impedance matching pads has a 5.7db theoritical insertion loss; true loss is 5.7db plus the normal other losses. common use is to connect 50 ohm sma's to 75 ohm f's. There are also 75 ohm versons of N's, BNC's, & SMA's.
-
product
Antenna Impedance Converter
The low noise impedance matching equipment has a high impedance input with minimized capacity. With the 50 Ω output it can be used with common EMI receivers or spectrum analyzers to measure the emissions received by an antenna on a vehicle.
-
product
Impedance Analyzers
MTZ-35.
An impedance analyzer with the features and specifications necessary for working on a the broad range of applications in the field of materials research.
-
product
Impedance Analyzer
TH2839A
Changzhou Tonghui Electronic Co., Ltd.
■ Freq: 20Hz-5MHz, max. resolution 1mHz ■ Test Accuracy: 0.05% ■ Test Speed: Max.7.7ms ■ Auto-balance bridge technology, 4-terminal pair ■ High stability and consistency: up to 15 test ranges
-
product
Precision Impedance Analyzer
TH2851-130
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-130MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration ■ High stability and consistency ■ High speed: the fastest test speed up to 5ms
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
Impedance Analyzer, 20 Hz to 10/20/30/50/120 MHz
E4990A
The E4990A Impedance Analyzer has a frequency range of 20 Hz to 120 MHz. The E4990A provides an industry best 0.045% (typical) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source. The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
-
product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.