High Definition TV
Digital broadcast television with higher resoultion than NTSC, SECAM and PAL.
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
High Current Probe
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
SHC68-68-RDIO, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable, 1m
191667-01
High Speed Digital Cable
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable 1m
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
High Current Probe
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
High-Voltage Differential Probe, 70 MHz
N2891A
High Current Probe
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
Product
AC / DC Current Probe, 100 KHz, 100 A
1146B
High Current Probe
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
High Current Probe
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
High Frequency Probe
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
WaveRunner High Definition Oscilloscopes
WaveRunner 8000HD Series
-
Providing 12 bits all the time, more channels than any other oscilloscope, and long memory without tradeoffs – the WaveRunner 8000HD 8 channel oscilloscope captures every detail.
-
Product
High-Voltage Differential Probe, 200 MHz
N2805A
High Current Probe
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
Product
N2782B AC / DC Current Probe, 50 MHz, 30 Arms
N2782B
High Current Probe
The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
Product
HDO6000B High Definition Oscilloscopes
HDO6000B Series
Oscilloscope
Providing 12 bits all the time, a bigger display, smaller footprint, and more capability, the HDO6000B captures every detail.
-
Product
DC Coupled Current Probe
34134A
High Current Probe
Measure a wide range of applications with this battery-powered, clamp-on probe; use with DMMs or voltmeters
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
TV Signal Generator
-
This device is equips with the simulator. The following condition can be simulated. Non Liner: Non-linear assumed the satellite repeater - AWGN: C/N assumed the rain attenuation.- Phase Noise: Phase noise assumed the LNB - Frequency Drift: Frequency drift assumed the LNB- Echo: Reflection by the reception wiring and so on The MPEG-2 TS and the TLV (Type Length Value) can be transmitted. The test stream generator is equipped. Thus, the files can be rewritten through the USB2.0 interface. A seven-inches WVGA touch-panel is equipped. Thus, an excellent operation ability is provided. The remote control through the Ethernet is possible.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
SAT/CATV/TV Signal Analyzer
DSA 1491
-
9” full-color, high-resolution touch screen user interface simplifies complex measurement tasksRF inputs including satellite, cable and terrestrial along with ASI and IP inputsDigital RF measurements including average power/level, pre/post BER, MER, noise margin, spectral analysis and constellation
-
Product
Analog TV Analyzer
BT-QAM-PRO
-
Blonder Tongue Laboratories, Inc.
The BT-QAM-PRO is an economical feature-packed test instrument for analyzing CATV QAM and Broadcast 8VSB digital channels, as well as NTSC analog channels. This compact instrument is designed with field service technicians in mind and provides many of the features that are typically only found in many higher-priced units. The BT-QAM-PRO comes complete with a soft water-resistant case and a micro USB charging/PC cable.
-
Product
4 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Oscilloscope
WavePro 404HD
Oscilloscope
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s.Up to 5 Gpts of acquisition memory enables detailed viewing of long events.15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector.MAUI with OneTouch user interface for intuitive and efficient operation.Deep toolbox enables and simplifies complex analysis.Intuitive navigation to quickly find important features in long waveforms.Zone Trigger – Simple Triggering for Complex Signals.
-
Product
Wide Angle High Definition Underwater Camera
Surveyor-WAHD
-
The Surveyor-WAHD underwater camera is designed to provide a 14% increase in angle of view, from the previous WAHD camera, whilst remaining compact and very competitively priced. It is ideal for ROV inspection tasks, scientific observation and broadcast applications.Video output is available as component (Y/PbPr), utilising standard connectors or HD-SDI on hybrid 75 Ω coaxial or fibre optic connectors, a composite video output is also available.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
TVS Diodes
-
Power TVS diodes provide outstanding protection for both alternating current and direct current power line applications by a Power TVS diode in a surface mount package. When compared to other devices, such as MOVs, power TVS diodes provide much better protection. Bourns provides a broad voltage range of devices with surge current ratings ranging from 3, 6, 10, and 15 kA to suit a variety of applications.
-
Product
47~862MHz & 950~2600MHz Satellite TV & Analog TV PIN Optical Receiver
HRS-26A
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HRS-26A optical receiver, adopting high-sensitivity PIN detector, Taking the technology of frequency division multiplexing, it can receive analogue CATV and SAT-IF signal with the frequency of 47~862MHz and 950~2600 Mhz over single fiber. It can be compatible with any FTTx PON to realize triple-play of analog TV, Digital TV (DBS-C, DBS-T), Satellite TV, Internet and FTTH.
-
Product
4 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Mixed Signal Oscilloscope
WavePro 404HD-MS
Oscilloscope
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s.Up to 5 Gpts of acquisition memory enables detailed viewing of long events.15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector.MAUI with OneTouch user interface for intuitive and efficient operation.Deep toolbox enables and simplifies complex analysis.Intuitive navigation to quickly find important features in long waveforms.Zone Trigger – Simple Triggering for Complex Signals.





























