Product
High-Power Digital Wattmeters
-
The Coaxial Dynamics High-Power Digital Wattmeters are designed for the accurate measurement of complex RF Waveforms such as CDMA (Code Division Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High Definition TV), as well as CW, AM and FM.
-
Product
75 Ohm HD Coax Contact
-
Ideal for video applications.Used for high definition TV transmission.Can be used in VPC hybrid iCon modules with 20/26 GHz contacts.
-
Product
Digital Wattchman Monitor/Alarm Systems
Model 91091
-
The Coaxial Dynamics 'Digital Wattchman' Rack Mounted Station Monitor/Alarm is similar in function and appearance to our 81090 Series except it is designed for the accurate measurement of complex RF Waveforms such as CDMA (Code Division Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High Definition TV), as well as CW, AM and FM.
-
Product
Brute Hight Current Probes
P4301
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Godzilla High Current Probes, 150 Amp
HC500
-
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Brute High Current Probe
P4301-2R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
-
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
-
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
-
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
RF High Frequency Probes
-
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Rogowski AC Current Probe, 23 MHz, 3000 A
N7040A
-
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
-
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Brute High Current Probe
P4301-1Z
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
High Resistance Measurement Universal Adapter
N1414A
-
N1414A High Resistance Measurement Universal Adapter is used to simplify the connection for high resistance measurements by B2980A series electrometer.
-
Product
Brute High Current Probe
P4301-1R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
SHC68-68-RDIO, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable, 1m
191667-01
-
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable 1m
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
-
100 – 187 mil (2.54 – 4.75 mm)
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
-
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
SHC68-C68-RDIO2, 68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable, 2m
156166-02
-
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 2m
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
-
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
-
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
-
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
Product
High Voltage Probe, 100:1, 3.7 KVpk, 500 MHz
10076C
-
The Keysight 10076C 3.7 kVpk, 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today's small power electronics components, and its rugged construction means it can withstand rough handling without breaking.
-
Product
AC / DC Current Probe, 100 KHz, 100 A
1146B
-
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
Product
Brute High Current Probe
P4301-2F
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
-
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
High Current Probes
-
*Low internal resistance to minimize arching*PogoPlus bias ball design*High current optimized base material and plating*Higher temperature spring design*Specialized high current tip geometry
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
-
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48