Product
PCIe X16 Intel Arc A380E Embedded GPU Card
EAI-3101
Graphics Card
PCIe x16 Intel Arc A380E Embedded GPU Card with 4x DP 1.4a. Intel Arc A380E with 2000 MHz Base Clock, GDDR6 6GB 96 bit Memory, up to 5.018 TFLOPS. 4x DP1.4a up to 8K UHD resolution. 0-60°C working temperature support w/ auto smart fan.
-
Product
SH25M-10F Cable, 25-Pin Male D-SUB to 10-Pin Female COMBICON, Shielded Multifunction Cable
190654-01
Multifunction Cable
25-Pin Male D-SUB to 10-Pin Female COMBICON, Shielded Multifunction Cable - The SH25M-10F Cable, sometimes referred to as SH10F-25M, connects C Series DAQ devices with a 10-pin screw terminal to a 25-pin D-SUB. The SH25M-10F Cable is offered in different lengths.
-
Product
Web Sensor
P8510
-
Thermometer Web Sensor P8510 or Web Sensor P8511 and Web Sensor P8541 are used tomeasure temperature or relative humidity. Temperature can be displayed in C or F. Relativehumidity have unit %RH. Communication with the device is realized via Ethernet network.
-
Product
Air Cooled Linear DC Electronic Load
ALx Series
-
The ALx Series utilizes conventional linear MOSFET-based dissipative elements, allowing the series to achieve a very wide voltage-current operating range within the model’s maximum power rating. Using the same heat management innovations developed for Magna-Power’s high density programmable DC power supplies, the ALx Series’ conservative cooling ensures long product life in environments up to 50 °C ambient operating temperature.
-
Product
Barometric Pressure Sensors
-
Accurate within 1.5 % across a pressure range of 15 to 115 kPa (4.43 to 34.96 in Hg). Long-term non-stability has been measured continuously indoors and in natural conditions (with sensors mounted inside a datalogger enclosure) for multiple sensors and is less than 0.5 % per year. Temperature effects on signal are less than 1 % across a wide temperature range (-20 to 50 C).
-
Product
LCR Meter
-
Precision Mastech Enterprises Co.
An electronic test device that measures Inductance (L), Capacitance (C), and Resistance (R) of components like capacitors, inductors, and resistors, often at various frequencies, to determine their actual values and parasitic characteristics beyond simple DC readings, essential for verifying component quality and suitability for circuits.
-
Product
Tenney Strat Altitude Test Chamber
-
Tenney's Strat Altitude Chambers simulate altitudes up to 200,000 feet. With an overall temperature range of -68°C to +177°C, humidity capabilities of 20% to 98% RH, and workspace sizes ranging from 5 to 64 cubic feet, this highly developed line of altitude test chambers offer one of the broadest selections in the industry.
-
Product
MCB Test Option, Monitor Voltage Adapter
PTE-FCB
-
The PTE-FCB / PTE-FCD can be used to effectively reduce the sensitivity of the monitor input. The monitor input detects the relay’s operation and stops (or starts) the chronometer when testing with the PTE-100-C, PTE-50-CE, PTE-50-CET, and all LETs excluding the LET-400 (which lacks a chronometer).
-
Product
NI-9220, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
785188-01
Voltage Input Module
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
Product
CiCi-Raman-NIR Spectrometer
-
HORIBA Scientific is the world leader in Raman spectroscopy, with a long history in the technique. HORIBA OEM has pioneered Raman systems for spectroscopy, designing and manufacturing them for over four decades. We provide miniature spectrometers and systems for industrial applications such as process control, security, pharmaceutical, medical and semiconductor. The CiCi-Raman-785 is our high performance spectrometer featuring an aberration-corrected concave holographic grating configured with Horiba Scientific's Syncerity™ TE-cooled CCD camera with a VIS-NIR 2048 x 70 detector, in a TE-cooled Head at -50° C.
-
Product
PXI Switch - 16-CH General-Purpose SPDT Relay Module
PXI-7901
Relay
ADLINK PXI-7901 is a general-purpose (GP) switch module implementing 16-CH independent single-pole double-throw (SPDT) relays (1 Form C). PXI-7901 can connect one input to one output and be used as signal switching and routing for measurement system or ATE. Thanks to its high switching capacity, PXI-7901 can also be used to turn on or turn off devices such as motors, fans, heaters, and lights. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7901, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
Temperature Measurement click board
Thermo J click
-
Thermo J click is a temperature measurement click board™, which uses a thermocouple type-J probe, connected to a PPC-SMP-J onboard connector. The active part of the Thermo J click is MCP9600 by Microchip - a thermocouple EMF to temperature converter, with 1.5°C of maximum accuracy. The onboard PCC-SMP-J connector ensures the secure connection and accurate readings for the connected thermocouple.
-
Product
Static Code Analyzer
PVS-Studio
-
PVS-Studio is a tool used to detect bugs in the source code of programs written in C, C++ and C#. PVS-Studio performs static code analysis and generates a report that helps a programmer find and fix bugs. PVS-Studio does a wide range of code checks; but it is especially useful to search for misprints and Copy-Paste errors. Examples of such errors: V501, V517, V522, V523, V3001.
-
Product
QSeven
ROM-7510
Computer-on-Module
*TI Sitara AM5728 Dual core cortex-A15 1.5GHz high performance processor*Onboard DDR3 memory 2 GB and eMMC Flash 8 GB*Support 1 LVDS, 1 HDMI, 1 USB2.0 OTG, 4 USB2.0 HOST, 1 USB3.0,2 UART, 1 CAN, 1 SATA, 2 I2C, 1 I2S, 2 PCIE 1 lane,*Operating temperature 0 ~ 60 °C / -40 ~ 85 °C*Supports Linux Yocto
-
Product
sbRIO-9853, Non-Enclosed, 2-Port, High-Speed C Series CAN Interface Module
780923-01
CAN Interface
Non-Enclosed, 2-Port, High-Speed C Series CAN Interface Module—The sbRIO‑9853 is a high-speed Controller Area Network (CAN) interface for developing FPGA‑based applications with the NI‑RIO driver on CompactRIO. These modules are ideal for low-level FPGA‑based control and triggering applications that are programmed using the NI LabVIEW FPGA Module. These modules also are ideal for byte-level manipulation of CAN frames in the NI LabVIEW FPGA Module. The sbRIO‑9853 is only compatible with CompactRIO systems. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9375 , 30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module
781030-01
Digital Module
30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The NI‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The NI‑9375 offers isolation between the input and output banks from channel‑to‑earth ground.
-
Product
Centesimal Thermometer Pt100
HD2107.1
-
Centesimal thermometer in the range ±199.99 °C, decimal outside this range, one input for Pt100 probes with SICRAM module measuring range -200 °C +650 °C.
-
Product
T-2/HT-2 Testing Solutions
-
T-2 and HT-2 mycotoxins are produced by Fusarium and other mold species that can commonly attack grains and can grow at temperatures from slightly above freezing to about 86°F (30°C). All domestic animals are susceptible to injury by dietary intake of T-2 in the range of a few ppm. In poultry, feed contaminated with 1.0 to 3.5 ppm of T- 2 has produced lesions at the edges of the beaks, abnormal feathering in chicks, a drastic and sudden drop in egg production, eggs with thin shells, reduced weight gains, and mortality.
-
Product
SH37F-Tajimi Shielded Cable, 10M
199254-10
Multifunction Cable
37-Pin D-SUB Female to 4 7-Pin Tajimi Female, C Series Strain/Bridge Input Module Multifunction Cable - The SH37F-Tajimi connects with compatible sensors to accessories or cables with Tajimi push-pull connectors.
-
Product
M-Module Carrier for CompactPCI (3U)
i3000
-
The i3000 M-module Carrier for CompactPCI features a 3U form factor CompactPCI gateway to the M-module interface. One M-module mounting socket is provided by this carrier. This carrier can be used in temperatures from -40°/+85°C. The M-module interface of the i3000 complies to the M-module Specification ANSI/VITA 12-1996. The interface features A8, A24, D16 and D32 access types.
-
Product
sbRIO-9236, Non-Enclosed, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module
781580-01
Strain/Bridge Input Module
Non-Enclosed, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The sbRIO‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The sbRIO‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. Non-enclosed modules are designed for OEM applications.
-
Product
Cable Assembly, 50-Pin D-Type, Male to Unterminated With Tinned Ends, 1m HV, Exit Towards Pin 1
A050DM5-T-HA100
Cable Assembly
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assembly can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
Product
Glycerine Refractometer, Freeze Point °C
PA202X-016-019
-
Celsius model – Glycerine measurement is fast and easy with the MISCO Palm Abbe digital refractometer. This refractometer has two scales, one for glycerine freeze point in degrees Celsius and one for glycerine concentration in percent by volume.
-
Product
8-Ch Digital Input Module
ADAM-3651
Digital Input Module
Rated Input : >5mA @ 12 VDCCurrent : >10mA @ 24 VDCInput Filter : Programmable, Default 3msPulse Input Frequency : 150HzOver Voltage Protection : +40 VDC-40 ~ 70°C operating temperatureSupports Sink (Wet Contact) / Counter input type
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
Multifunction I/O Device
Multifunction I/O
The Multifunction I/O Device features I/O with varying channels, sample rates, output rates, and other features to meet many common measurement requirements. You can use the device for industry applications such as laboratory automation, research, and design verification. The included DAQExpress companion software provides basic measurement and analysis, while the included NI-DAQmx driver provides the ability to create customized automated measurement and control applications. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
IEC 61850-3 L2 Modular Managed Switch
EKI-8528-4XFL
-
3 x 8 Gigabit ports module slots + 4 x 10G SFP+ portsDual power input options for 110/220V AC or 24-48V DC power moduleFully layer 2 and TSN-enabled functionsFeatures IEEE 802.1AS Time Synchronization, IEEE 802.1Qbu Frame Preemption, IEEE 802.1Qbv Time Aware Shaper and IEEE 802.1CB Seamless RedundancyRedundancy: X-Ring Pro (< 20ms @250units), X-ChainManagement: SNMP v1/v2c/v3, WEB, Telnet, standard MIB-40 ~ 75˚C wide-range operating temperature
-
Product
Industrial Serial GSM Modem
ENVIROMUX-GSM-IND
-
Sends SMS messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. SIM card supporting SMS messaging required (not included). Ideal for harsh environments and high temperatures up to 149°F (65°C). GSM/GPRS/EDGE 850/900/1800/1900 MHz. AT command compatible. Dimensions: 3.58x2.28x0.87 in (91x58x22 mm). Operating temperature: -13 to 149°F (-25 to 65°C). Operating humidity: up to 95% non-condensing RH. Regulatory approvals: CE, C-Tick. Compatible with ENVIROMUX-SEMS-16(U).
-
Product
PCI GPIB Controller Card
Model 488-LPCI
Controller
* Adds GPIB Controller capability to any PC with a PCI bus.* Fast >1 Mbs transfer rate* 488.2V4 Driver supports 32 and 64-bit Windows XP, Vista, Windows 7, Windows 8 and Windows 10 with a true 64-bit DLL.* Driver compatible with industry standard 'ib' and '488.2' command sets.* Most affordable PCI-GPIB controller with a industry standard GPIB-32.dll.* Works with Agilent, NI and Kikisui VISA libraries.* ICS's Explorer auto configures your controller as it finds your instruments.* Use ICS's Explorer to control GPIB devices without having to write a program. * Program with Visual Basic, C, LabVIEW, Matlab or Agilent VEE* GPIB Card supports HP-IB Bus Systems.* Includes short bracket for lo-profile chassis.
-
Product
Dual QAM-A/B/C Receiver For PCIe
DTA-2136
-
DekTec's PCIe QAM-receiver card for J.83 Annex A, B and C. The DTA-2136 has two onboard demodulators, combined with two ASI output ports for monitoring the receiver output or for independent stream playback.