Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1846 - 1860 of 2437 items found.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2220 - TREK, INC.

    Trek’s Model 2220 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2210 - TREK, INC.

    Trek’s Model 2210 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and auto recovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Acoustic Probe

    AA-Ultrasonic - IPEC Ltd.

    The AA-Ultrasonic acoustic probe is designed for use on air insulated terminations where a clear sound path between the electrically stressed insulation and the probe is present. The sensor is extremely sensitive and can detect activity below 10pC. The probe has a magnetic base to allow coupling to steel enclosures and a swivel head as so the detecting sensor can be aimed directly at the HV point. Corona in air and surface tracking can seriously damage high voltage insulating surfaces in a way that will ultimately lead to flashover and complete failure of the insulator. This discharge activity creates acoustic emission that can be detected using a high frequency sensor. The magnitude of the acoustic emission is indicative of the degree and severity of the discharge activity.

  • Precision DC Power Module, 20V, 50A, 500W

    N6765A - Keysight Technologies

    The Keysight N6765A is a 500 W precision DC power module that provides low noise, and precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. This module is used in both the small, multiple output 1U high N6700 Low-Profile Modular Power System (for ATE systems) and the multiple output N6705 DC Power Analyzer (for bench testing). GPIB, LAN, USB and LXI compliance are standard. Select from more than 30 different DC power modules ranging in capability from basic to high precision, and in power from 20-500 Watts.

  • Surface & Volume Resistivity Meter for Nonconductive Materials

    Hiresta UX - OAI

    The new Hiresta-UX is a high performance meter for measuring the surface and volume resistivity of a wide variety of nonconductive materials. With an extended measurement range of 103 ~ 1014Ω, this meter is ideal for Production, Engineering, R&D and Quality Control. The new Hiresta-UX features powerful new algorithms that automatically choose the right voltage, which optimizes the surface and volume resistivity testing. This versatile, high performance resistivity meter includes a built-in switch box that can be mated with a J-Box (meets JIS K 6911 for surface & volume resistivity and is compatible with ASTM D 257) as an option. The Hiresta-UX can store up to 2,000 measurement results, which can be easily exported to a USB memory device.

  • C Series Voltage Output Module

    NI

    The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Cable Fault Locators

    Fiberinthebox

    Cable Fault Locator is a device used for short circuit faults, cable cuts, resistive faults, intermittent faults, and sheath faults. Fiberinthebox supply cable fault locator for power cable, optical fiberal cable, etc. Fault Location in Power Cable is designed to locate cable faults, pinpointing the fault location, route tracing, cable identification, voltage withstand test and cable information management. It can locate all kinds of cable faults for all voltage level cables, including open circuit, short circuit, low insulation, high insulation and flashover faults, etc. Most power cables were buried underground, invisible, and out of reach, with modern new power cable fault locater, it can find the fault point quickly, solve problems immediately and restore power supply.

  • Inductive Sensors

    Bernstein AG

    In general, inductive proximity switches consist of four basic elements: a coil, an oscillator, a threshold switch and an output stage with short-circuit protection.The oscillator generates a high frequency, electromagnetic alternating field which is emitted from the active face of the coil.Eddy currents are induced in a metal object that enters this field. These eddy currents draw energy from both the electromagnetic field and from the oscillator which is consequently attenuated.The more energy taken the closer the metal object moves towards the active face. The threshold switch switches on the output stage at a defined attenuation value.In proximity switches with a DC voltage supply, this switch is designed as an NPN transistor which switches the connected load to the negative pole or as a PNP transistor which switches the load to the positive pole. The output stage is a thyristor or a triac in AC voltage switches.

  • Three Phase AC Power Source

    TFC63 Series - Twintex Electronics Co., Ltd

    The TFC63 series are three phase output AC power source, output capacity from 500VA to 800kVA. Adopting PWM high frequency technology & IGBT regulation mode, the TFC63 series features constant frequency and voltage with high accuracy. The TFC63 series can be used to simulate grids of different countries, widely used in laboratories, production calibration & test and military applications.

  • Single Phase AC Power Source

    TFC61 Series - Twintex Electronics Co., Ltd

    The TFC61 series are single phase output AC power source, output capacity from 5kVA to 800kVA. Adopting PWM high frequency technology & IGBT regulation mode, the TFC61 series features constant frequency and voltage with high accuracy. The TFC61 series can be used to simulate grids of different countries, widely used in laboratories, production calibration & test and military applications.

  • Laser Diode Burn-in Reliability Test System

    58604 - Chroma ATE Inc.

    The Chroma 58604 is a high density, multi-function, and temperature controlled module for laser diode burn-in and lifetime tests. Each module has up to 256 SMU channels which can source current and measure voltage in various control modes as described below.

  • Analogue (1kV below) Insulation Tester

    2732 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.

  • Analogue (1kV below) Insulation Tester

    4132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.

  • Timer, Delay-Off, 4 Pole

    TDE4N relay - - Mors Smitt Group

    Plug-in electronic industrial timer relay with four change-over contacts. When the relay is de energized there is a delay on drop-out without any auxiliary power supply. The delay time is adjustable with a lockable knob. The relay can also be supplied with a fixed time delay (no knob).The relay is equipped with a LED which indicates the presence of energizing voltage. Standard equipped with back EMF suppression. Optionally equipped with magnetic arc blow-out for high breaking capacity and long contact life.

  • Non-Contact Type Magneto-Electric Rotation Detector

    MP-9820 - Ono Sokki

    MP-9820 is a magneto-electric-rotation detector using an internal hall element, a permanent magnet, DC amplifier, and voltage regulator in its compact body. Using MP-9820 in combination with detection gear enables deriving stable rectangular waveform from ultra low speed all the way through high speed. (1 Hz to 100 kHz)MP-9820 finds wide range of applications and rotational measurement objects by using with TM-3100 series tachometer and FV-1500 FV converter.

Get Help