Showing results: 136 - 150 of 450 items found.
-
Coherent Corp.
Wide-ranging line of laser power and energy measurement products that deliver accurate, ISO/IEC 17025 certified measurements, and laser beam diagnostics systems that measure spatial intensity distribution and beam size. All backed by more than 50 years of industry experience, with worldwide service and support.
-
Neocera, Inc.
Neocera offers a variety of components that can be fitted and combined into new or existing PLD and PED systems to provide improved functionality and enhanced capability. Components include:*Oxygen-compatible substrate heaters for epitaxial oxide film depositions..*Automated Target Carousels for preparing multilayer heterostructures.*Deposition chambers design specifically for PLD and PED systems.*Manual and automated laser window-change Accessories.*Pulsed Electron Deposition (PED) sources for laser transparent materials.*Ideal for retrofitting existing systems or construction of new systems.
-
Keysight Technologies
Keysight VME electronics give the highest performance available in a laser interferometer system. Choose from a variety of axis and compensation boards.
-
Renishaw Inc.
Renishaw's laser interferometer and ballbar measurement systems assess, monitor and improve the static and dynamic performance of machine tools, co-ordinate measuring machines (CMMs) and other position-critical motion systems.
-
Automated Precision Inc.
The award-winning XD Laser is a multidimensional laser measurement system that simultaneously measures all 21 degrees of freedom including linear, angular, straightness and roll errors for rapid machine tool error assessment. Measurements Include:- Rotational accuracy- Geometric error- Angular error- Flatness- Squareness- Parallelism
-
iChrome CLE -
TOPTICA Photonics Inc
TOPTICA's iChrome CLE is a compact laser engine that combines four laser lines in one box. All integrated colors are provided via one polarization-maintaining single-mode fiber. It is available with 405, 488, 561 and 640 nm and more than 20 mW guaranteed output power after the fiber each. The system guarantees a plug & play installation since it includes TOPTICA's proprietary COOLAC automatic alignment technology. This way the system is ready-to-use after one simple button click. 561 nm laser light is generated by TOPTICAs proprietary FDDL technology. Each laser line can be directly modulated up to a frequency of 1 MHz and TOPTICA's "Complete OFF" mechanism guarantees zero photons in the "off"-state.
-
Micro-Epsilon Group
The SHSLab wavefront sensor system is a powerful and comprehensive measurement solution for a multitude of optical applications, such as:*alignment of optical systems *measurement of imaging quality*surface shape measurement*laser beam characterization
-
10753B -
Keysight Technologies
The Keysight 10753B Tripod provides a mounting for the Keysight 5519A/B laser head. The tripod allows Keysight 5530Laser Calibrationsystem optics to be located remotely from the laser head, yielding greater accuracy and simplifying fixturing. The remote setup also eliminates heat-caused distortions. The Keysight 10753B adjusts for height, rotation, tilt, and lateral offset. The tripod is collapsible, covers a height range of 900 mm (35.5 in) to 1630 mm (64.0 in), and has a net weight of 14 kg (31 lb). The Keysight 10753B tripod complements a family of measurement optics and lasers that comprise Keysight laser interferometer calibration systems.
-
LP-RV SERIES -
Panasonic Industrial Devices Sales Company of America
The LP-RV Series FAYb Laser Marker features:- Short Pulse 20W Fiber Laser Offers Excellent Mark Contrast On Difficult To Mark Plastics And Various Other Materials- Optional EtherNET/IP Or ProfiNET Interface Adaptor Card- Modular Laser Oscillator System Makes Servicing In The Field Possible - Direct Connection To Panasonic PV230 Vision System For Mark Verification, Auto-Targeting, And Other Machine Vision Functions- Compact IP64-Rated Marking Head For Use In Harsh Environments- Compliant With FDA Regulations, GB Standard, KC Mark, Machinery Directive (Declaration of Incorporation), EMC Directive, RoHS Directive
-
BeamWatch -
mks Ophir
The patented BeamWatch non-contact profiling system accurately captures and analyzes industrial multi-kilowatt lasers wavelengths from 980nm - 1080nm by measuring Rayleigh Scattering. It features a complete passthrough beam measurement technique, no moving parts, and a lightweight compact design which makes it ideal for comprehensive analysis of industrial multi-kilowatt lasers
-
Edmund Optics Inc.
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
Shanghai Stone Communication tech Co., Ltd
These bench-top laser source has built-in high-feature Semi-conductor laser device, it is the SM output, with less than 10MHz plus width. Based on the advanced micro-processor control system, this instrument integrated high precision ATC and ACC(APC) to control the electric circuit, in order to realize the high stable output of the laser device, and make the operation easily and directly. We also can provide user required communication port with the software to realize remote control from the PC.
-
PN-100BI -
NAPSON Corp.
*Principle: Photovoltaic effect with the laser diode*Suitable for production line and tranceportation system*Connect to host PC by LAN to send measurement command and data
-
OEwaves, Inc
OEwaves’ HI-Q® Optical Test Measurement System utilizes a homodyne methodology for automated measurement capable of testing ultra-low phase noise laser sources. The user friendly test system is capable of rapidly measuring laser phase noise and estimating its FWHM linewidth down to < 3 Hz without complex setup or reference lasers normally required to make such a narrow linewidth measurement.
-
Keysight Technologies
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. All models can reach any wavelength point within their specified wavelength in the C- and L-band range. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. The Keysight N7711A and N7714A tunable lasers are available in a compact format with half-rack width and one rack-unit height. This format makes them the right choice for high channel-count system load applications.