Current Transformer Test Set
See Also: Transformer Test, Transformer Testers, Current Transformer Test
-
Product
Calibration Foils Sets
990
-
The Elcometer 990 Calibration Foil Sets are ideal for use in the laboratory, on the production line or on site.
-
Product
Flight Termination Test Set
-
Kratos Defense & Security Solutions, Inc.
The FTTS accepts AC power and generates a modulated RF output suitable for interrogation of flight termination receivers and/or command receiver/decoders. The FTTS can transmit up to 6 tones simultaneously and the RF output power is adjustable from 0 to -127 dBm. The IRIG tones can be switched ON/OFF independently from the control panel. A 20 Tone version of the FTTS is also available.
-
Product
Isolation Transformers 230V
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
Product
Four-module test set
F8200
-
Use the F8200 Power System Simulator for testing single-phase conventional schemes, digital protection systems, and more. This four-module F8000-series instrument is available in four standard configurations of HVA Current, HVA Voltage, and Low-Density Logic I/O modules.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Lightning Current Generator
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
Product
Testing Services Test
-
Aero Nav Laboratories is uniquely positioned to provide testing services that promote safe and reliable products, which are in compliance with the government and industry standards.
-
Product
True RMS Current Clamps
-
PeakTech Prüf- und Messtechnik GmbH
Current clamps are ideal for current measurement in electrical systems and control cabinets, since only single wires are guided through the clamp jaws for contact-free current measurement and no electrical connections have to be disconnected. In addition, this model has extensive multimeter functions for voltage, resistance, frequency, capacitance and temperature measurement.
-
Product
Test Program Sets (TPS)
-
Data Review, Corrections, & Generation (Reverse Engineering). Technical Requirement Documentation (TRD). Test Strategy Reports (TSR). Test Program Development – Software. TPS Sell-Off & Acceptance. Life-Cycle Support. Technical Interface Test Adaptors (ITA) – Hardware. Training - TPS Development, ATE/TPS Operator, Fault Diagnostic, ATE Maintenance.
-
Product
Current Transformer
ST-12RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
Product
High Current Switches
-
Marvin Test Solutions’ switch card portfolio includes matrix, multiplexer, and RF multiplexer configurations. 3U and 6U PXI switch cards feature easy to use, reliable, and integration-friendly D-sub style interface connectors – a feature unique to Marvin Test Solutions PXI switch cards. GENASYS switch cards are compatible with MTS’s family of GENASYS Switching and Switching/Digital Subsystems, featuring integrated MAC Panel SCOUT receivers.
-
Product
OEM Current Input0 to 20mA
TGPR-0800
-
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
Product
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)
ZCT-140
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Leakage current measurements of feeder*Compact size*AC 1mA~300A
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
High-Voltage, High Current I/O Module
Model JI-4516
-
The JI-4516 module is a versatile, easy-to-use device for adding high-voltage, high-current digital I/O capability to a computer system via a USB connection. The module is comprised of 8, low-side power MOSFET switches, and 8 high-voltage inputs. I/O ground isolation eliminates ground-loops and provides protection from noise and switching transients during high-current load switching. The JI-4516 is available as either a desktop unit or low-cost OEM board.
-
Product
Multiple Gas Transformer DGA
MINITRANS
-
Based on the same core technology as the highly successful TRANSFIX the MINITRANS is a lower cost alternative, monitoring three key gases: Hydrogen, Acetylene and Carbon Monoxide (in ppm) plus moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect a wide range of developing faults including arcing.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Relay Test Set
-
Relay testing equipment is a portable apparatus designed for checking the operating characteristics of protective relays on site. Rr Relay Testing Equipments are designed to facilitate routine test or periodic maintenance test of relays by simulating (as early as possible) fault conditions under which the protective relays are required to function. There are several approaches to the method of testing relays on site. The Relay Testing Equipments are secondary injection type and are intended to be used to test the relays after isolating them from live systems, either physically or electrically.
-
Product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
-
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
Product
Digital Current Integrator
-
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure DC currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.
-
Product
Instrument Transformers Tester
TE30
-
Calmet Smart Calibration Devices
Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
Product
Automotive Current Tester LCD Display
77102
-
This automotive current tester with LCD display, plugs directly into the fuse box and can be used on mini, standard and maxi fuse connections. Blades may get hot during use and care should be taken for 2mins whilst they cool down. Fits mini and maxi fuses. Current range 0-80AMP. Safe and easy way to check automotive current.
-
Product
Integrated Current Sensors
FHS Series
-
*Standard package and small footprint*Cost effective*Standard SOIC 8 surface mount PCB
-
Product
Field Current Regulator
-
We are counted amongst the leading names in the industry, offering wide range of Field Current Regulator. Our entire product line ensures easy operations and is performance based. Field Current Regulator are quality tested and are delivered in standard configurations. Our entire product range has high strength and is delivered at most affordable rates.
-
Product
Telcom Test Sets
T62 Recon
-
The RECON is the first true 21st century telecommunication line analyzer setting a new standard for POTS butt sets. It is a field instrument that delivers more information of online conditions & status than any other test set on the market, anywhere in the world!!
-
Product
Verification And Diagnostic Tools
Y1131A
Test Fixture
Provides module-specific tests to troubleshoot relay failures and predict maintenance requirements.
-
Product
Current Transformer Analyzer
CT Analyzer
-
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
Product
Current Clamps
-
Due to its variable measuring functions, the digital clamp meter can be operated universally. Useful details, such as the large display, manual or automatic ranging and measurement position lighting, makes operation particularly easy and reliable.
-
Product
Current Probe
PA-659
-
*Maximum Current Value: +/- 150ADC, 100A RMS*1mA = 5mA, 50mA (switchable)*Rising Time: 0.7uS*Bandwidth: DC ~ 500kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages





























