Standard Transformers
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Cup Reduced Concave, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0G12
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard & Top Paint Inspection Gauges
121/4
-
is a hand-held paint gauge that offers a quick, versatile method of coating examination and measurement in a portable, easy-to-use format.
-
Product
Innovative Open Standard
PROFINET
-
PROFINET is the innovative open standard for Industrial Ethernet, development by Siemens and the Profibus User Organization (PNO). With PROFINET, solutions can be implemented for factory and process automation, for safety applications, and for the entire range of drive technology right up to clock-synchronized motion control. PROFINET is standardized in IEC 61158 and IEC 61784. Profinet products are certified by the PNO user organization, guaranteeing worldwide compatibility.
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1V-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Comprehensive Standard Software
Halicon
-
MVTec HALCON is the comprehensive standard software for machine vision with an integrated development environment (HDevelop) that is used worldwide. It enables cost savings and improved time to market. HALCON’s flexible architecture facilitates rapid development of any kind of machine vision application. HALCON provides you with continuous access to the latest technologies to solve machine vision applications. Find out more about the different editions and their release cycle.
-
Product
Split type AC Current Transformer
CTS-400
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
Product
15T Standard Running Line Monitor
RLM15T-3.0-S
-
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-7
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Fully Automatic Transformer Turns Ratio Tester
DY100
-
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
Product
Isolation Transformers 230V
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
-
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HC-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H150-1
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3H
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2SB-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50D
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Harmonic Mitigation Transformer
-
A specialized three-phase transformer designed to reduce harmonic distortion and voltage distortion caused by non-linear loads (e.g., computers, VFDs) in electrical distribution systems.
-
Product
Transformer Test Equipment
-
A range of equipment dedicated to the testing of transformers of all types and sizes.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T36-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Power Transformer Monitoring
-
Optimize the efficiency of your transformers by relying on our flagship DGA monitoring system with long-term stability, no maintenance needs, no false alarms and a revolutionary method for detecting ambient air ingress.
-
Product
L.V. Current Transformers
-
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2250-9
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72J-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard VXI Module Shield Kits Without Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Same design described above but without the address switch opening.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3T
-