Showing results: 121 - 135 of 1619 items found.
-
40-580-001 -
Pickering Interfaces Ltd.
The 40-580 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 32x8 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
40-521-021 -
Pickering Interfaces Ltd.
An ultra high density matrix module is configured as a 24x8, this range is availablein a choice of reed relay formats: 1-pole (shown here), 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability RutheniumElectro-Plated Reed Relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance.
-
40-531-021 -
Pickering Interfaces Ltd.
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-531-021-S -
Pickering Interfaces Ltd.
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-532-021 -
Pickering Interfaces Ltd.
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-522-021 -
Pickering Interfaces Ltd.
Medium density PXI dual 12x8, 1-pole matrix - it is also available inreed relayformats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable forswitching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems.The two banks may be used for operating a 4-wire measurement system (bank-1 for source,bank-2 for measure). Larger matrices may be constructed by daisy chaining the commonsignals from multiple PXI Modules.
-
40-522-022 -
Pickering Interfaces Ltd.
Medium density PXI dual 12x8, 2-pole matrix - it is also available in reed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
40-584-001 -
Pickering Interfaces Ltd.
Our model 40-584, along with the following models40-584, 40-585, 40-586A and 40-587Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
40-523-022 -
Pickering Interfaces Ltd.
Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
40-586A-001 -
Pickering Interfaces Ltd.
Our model 40-586A, along with the following models40-584, 40-585, 40-587Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
40-524-021 -
Pickering Interfaces Ltd.
Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
40-511-022 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-511-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-511-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-505-001 -
Pickering Interfaces Ltd.
This range of medium density PXI matrix modules (40-505 thru 509) are able to switch up to 2 Amps or 300VDC/250VAC and come in42x4, 32x6, 25x8, 18x12 and 14x16 options. The modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 160-pin DIN 41612, 78-pin D-type or 50-pin D-Type connector that is fully supported by the wide range of our cable and connector accessories.