Filter Results By:

Products

Applications

Manufacturers

Showing results: 256 - 270 of 334 items found.

  • Portable Electrical Management Systems

    EMS-PT30C - Progressive Industries

    Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.

  • RV Power Protection with Surge

    EMS-PT50C - Progressive Industries

    Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.

  • Digital Multimeters

    all-sun

    * LCD display, Max.displayed value: 6000(frequency: 9999)* Measures the true-rms values of AC voltage and AC current.* Transfers the measurement readings of the meter to a computer through standard USB port * Data-hold mode * Analog bar graph(61 segments), reading unit indication and backlight * Automatic polarity indication* Manual range mode and autorange mode * Automatic/manual power-off * Relative value measurement * Max./Min. measurement* Overload protection, CAT III 1000V * Provides low battery indication

  • Current Transformer Testers

    Vanguard Instruments Company, Inc.

    Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface

  • Multi-purpose Cable Tracer and Non-contact Voltage Detector

    168 CB - Standard Electric Works Co., Ltd

    ● Four transmitter plug types - RJ-11 - RJ-45 - COAX - Alligator clips ● Two unique audible tones: - Fast alternating tone - Slow alternating tone ● Telephone line polarity check - Tip side - Ring side● Cable tracing ● Telephone line status check - Clear line - Busy line - Ringing line ● Continuity check.● Transmitter plug storage.● Easy to store different kinds of transmitter plugs (RJ-11, RJ-45, COAX, and alligator clips).● Easy to carry.● Flashlight function.

  • Gaussmeter

    GM2 - Alpha Lab, Inc.

    The Model GM2 Measures the strength and polarity of magnetic field up to 30kG when using a standard probes, or 800 gauss (resolution 0.01 gauss) if an HS probe is used. Functions include DC, AC and peak hold along with a user-adjustable alarm which has three modes of operation. DC background field can be subtracted out either by pressing "Relative Zero" or by manually adjusting the offset. The meter includes battery, AC adapter analog output jack and calibration certificate. If a standard probe is used, resolution is 0.1 gauss up to 19,999.9 gauss, which is stronger than the field of any permanent magnet. This 5 digit display allows measurement of tiny difference in strong fields. Above 20kG the meter autoranges to a 30kG range.

  • Passive Component ATS

    Chroma ATE Inc.

    Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe

  • Automated Optical Inspection (AOI)

    TR7700 SII - Test Research, Inc.

    Featuring a large 4 MP color camera and capable of inspection speeds of up to 120 cm2/sec at 15 µm, the TR7700 SII automated optical inspection system offers TRI' trademark Dynamic Imaging technology for powerful pre/post reflow inspection in a slimmer, faster and more economical package. The system features an advanced, highly flexible RGB+W lighting system with ultra-low-angle lighting for better inspection of polarity and black components and is capable of inspecting 01005 fine pitch components in both lead-free and legacy PCB assemblies.

  • Handsfree Telephone Communication Tester

    TestPhone 850 - JSD TestPhone Ltd

    The TestPhone 850 provides both handset and handsfree telephone communication. The product provides a standard Public Switched Telephone Networks (PSTN) interface, user interface and handset and/or handsfree vocal interface to allow the user to originate or answer standard PSTN calls on both Dual-tone Multi-frequency (DTMF - tone dialling) and Loop Disconnect (LD - pulse dialling) lines. In addition the product features on-hook audio line monitoring, PSTN line polarity indication, automatic on-hook/power-off and integral ADSL digital line filtering.

  • PXI Solid State Matrix Module, 6x2, 30 A

    40-554B-011 - Pickering Interfaces Ltd.

    The 40-554B-011 is a high current 6x2 matrix occupying two PXI chassis slots. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid-State Matrix Module, 6x2, 10 A

    40-553A-011 - Pickering Interfaces Ltd.

    The 40-553A-011 is a high current 6x2 matrix occupying two slots of PXI chassis. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Switch Module, 6xSPST, 30 A

    40-183B-011 - Pickering Interfaces Ltd.

    The 40-183B-011 has 6 high current SPST switches in two PXI chassis slots. Each SPST switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each SPST switch can support 30A of continuous current and switch up to 40V signals. The switch can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PID Insulation Tester

    TOS7210S - Kikusui Electronics Corp.

    The PID insulation tester (TOS7210S) is designed based on the insulation resistance tester (TOS7200) to carry out the evaluation of the PID (Potential Induced Degradation) effect of the PV module precisely and efficiently. Being equipped with the output ability of 2000 V and the ammeter with nA resolution as well as a polarity switching function, the TOS7210S is also applicable not only to the PID evaluation but also the evaluation of the insulators that requires a high sensitivity of measurement. The tester is equipped with the panel memory that is externally accessible and RS232C interface as standard; it can be flexibly compatible with the automated system.

  • DC Gaussmeter

    GM1-ST - Alpha Lab, Inc.

    The Model 1-ST measures strength and polarity of magnetic fields up to 19,999.9 gauss. The sensor can easily fit in a .060 inch (1.5 mm) gap and is at the end of a 100 cm flexible cable. The sensor end can be bent if required for a variety of situations. Place the sensor on a magnet face to measure the field. With a resolution of 0.1 gauss, it can measure any tiny variation from magnet to magnet or it can detect if a given magnet has lost even a little strength. Bend the sensor in to a "L" to measure inside a DC solenoid tube. The 5 digit display requires neither auto nor manual range change, making it easier to use than older style 3 or 4 digit meters. Turn on the meter and immediately begin reading fields (updates 4 times per second). There is no setup required, making this the fastest, easiest gaussmeter available.

  • Dual Channel Clock Driver Card

    PI-41400 - Pulse Instruments

    The PI-41400 is a dual channel Clock Driver card capable of operating up to 190 MHz into a 50-ohm load and up to 80 MHz at an amplitude of 8 volts into a 1-megohm load. Into a high impedance load the output voltage range is from a –3 volts to 8 volts with the output pulse amplitude ranging from 0.5 V to 9 V. When driving a 50 load the voltage range is –1.5 volts to 4.5 volts with the output pulse amplitude ranging from 0.25 V to 4.5 V. The rise and fall times of the output pulse are variable from 1.2 ns to 9 ns into a 50-ohm load and <5 ns to 9 ns into a HiZ load. The output pulse amplitude and the load being driven determine the range of variability. The driver output can be set for tri-state operation and the output polarity can be set for ‘Normal’ or ‘Inverted’ operation through software.

Get Help