Showing results: 211 - 225 of 263 items found.

  • Turnkey Laboratory Acquisition Systems

    Pacific Instruments, Inc.

    Series 6800 for laboratory applications is a ready-to-run, high performance measurement system. Enclosures are 3U rack mountable or can be used right on the desktop. 6800 units come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers, BNC for voltage or ICP/IEPE inputs or a 3-wire military grade connector.

  • ENERGY METER TEST BENCH

    GF102 - Beijing GFUVE Electronics Co.,Ltd.

    The GF102 is used to test single phase energy meter error. Adopt mature signal synthetic and power amplifier technology, high precision 500V voltage and 120A current output, accuracy 0.05%, automatically test all kinds of single phase enegy meter.

  • Matched Transistors

    Analog Devices Inc.

    Analog Devices offers dual and quad transistors with excellent matching characteristics. Offset voltages, temperature drift, and hFE matching are individually tested to data sheet specifications. Device performance is guaranteed over industrial and military temperature ranges. Each of these devices is an excellent choice as an input stage for an amplifier or in log/antilog circuits. ADI’s matched transistors offer low noise and high gain, with characteristics approaching an ideal transistor.

  • Turnkey Portable Acquisition Systems

    Pacific Instruments, Inc.

    Series 6800 for portable applications is a ready-to-run, high performance measurement system that is DC powered for mobile applications. All connections are front mounted for easy installation in tight places or on the go. 6800 systems come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers or BNC for voltage or ICP/IEPE inputs.

  • Portable Vibration Calibrator

    AT-2040 - Agate Technology

    With AT-2040 you will find the features required for your application without having to install cumbersome and expensive addons. AT-2040 features a full-automatic sensitivity test mode, sensor simulation, power supply output for sensors that require voltage such as the 7310 and 991V aviation sensors, a built-in sensor charge amplifier for both single-ended and differential charge accelerometers, and a custom sensor input that can be configured to fit most accelerometers with a one to one cable.

  • AC Source

    AFV - Intepro Systems

    The AFV Series is a broad line of programmable three phase AC power sources. With Power levels ranging from 15kVA up to 2MVA, the series powerful FPGA+ARM based controller offers precise voltage and frequency conversion with power disturbance generation capability. Power is supplied by state-of-the-art IBGT pulse-width-modulated power amplifiers resulting in highly efficient power conversion, compact design and maximized performance.

  • High-Voltage Power Amplifier

    Model 40/15 - TREK, INC.

    The Model 40/15 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slewrate, wide bandwidth, and low-noise operation. It is configured as noninverting with a fixed gain of 4000 V/V and is protected against overvoltage and overcurrent conditions that may be generated by active loads or by output short circuits to ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or for use as feedback signals in a closed-loop system.

  • Power Monitors

    Analog Devices Inc.

    Analog Devices’ power monitoring amplifiers provide an integrated solution for digital current and voltage measurement via an on-chip, 12-bit analog-to-digital converter (ADC), communicated through an I2C interface. Leveraging ADI’s precision analog design techniques, ADI’s products are twice as precise as competing devices, offering best-in-class accuracy (<±0.8%). The power monitors complete the industry’s only monitor and sequencer family to deliver <±1% accuracy for 2 to 12 supplies.

  • Non-Contact Type Magneto-Electric Rotation Detector

    MP-9820 - Ono Sokki

    MP-9820 is a magneto-electric-rotation detector using an internal hall element, a permanent magnet, DC amplifier, and voltage regulator in its compact body. Using MP-9820 in combination with detection gear enables deriving stable rectangular waveform from ultra low speed all the way through high speed. (1 Hz to 100 kHz)MP-9820 finds wide range of applications and rotational measurement objects by using with TM-3100 series tachometer and FV-1500 FV converter.

  • PXI Source/Measure Unit

    Keysight Technologies

    Keysight PXI source/measure unit (SMU) offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. It delivers industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading for faster test time.

  • Logarithmic Transimpedance Amplifiers

    Analog Devices Inc.

    Analog Devices translinear logarithmic amplifiers utilize advanced translinear techniques to provide an exceptionally large dynamic range in a versatile and easily used form. Our portfolio relies on proprietary innovations in design and precision laser trimming to achieve the wide measurement range and accuracy in products such as the AD8304 and AD8305. ADI translinear logarithmic amps are used in a variety of applications including optical power measurement, wide range baseband logarithmic compression, the measurement of current and voltage ratios, and optical absorbance measurements.

  • Signal Conditioners

    Load Cell Central

    Our load cell signal conditioners / amplifiers are just the thing when a digital display is not required, for example, applications in which the weighing system is controlled or monitored by a computer or PLC. These units supply the needed excitation voltage to power up the load cell(s). The wide range of models offered provide a variety of accuracy and frequency response levels, and signal outputs such as 0-10VDC, +/-10VDC, 4-20mA, RS232, RS485, USB, and frequency. Both AC & DC powered units are available.

  • Low Phase Noise Amplifiers

    Pasternack Enterprises, Inc.

    Pasternack's low phase noise amplifiers cover select frequency bands ranging from 1.5 to 18 GHz with residual phase noise levels as low as -180 dBc/Hz @ 10 KHz offset. Additional performance specs include small signal gain ranging from 9 to 14 dB, with typical noise figure of 5.5 dB. Psat levels for these amplifiers range from +16 to +25 dBm with Output IP3 levels as high as +34 dBm. All models feature single DC voltage supplies and input/output RF ports are internally matched for 50 ohms with DC blocking capacitors. These compact module assemblies require no external components and are available in rugged Kovar metal drop-in packages that are gold-over-nickel-plated and support field replaceable SMA connectors. All models are EAR99 and guaranteed to meet MIL-STD-883 test conditions for hermeticity and temperature cycle.

  • Digital Control VGAs

    Analog Devices Inc.

    Analog Devices digital controlled variable gain amplifiers provide discrete levels of gain control over a fixed number of control bits for a variety of audio and optical frequency bands. Our VGAs improve the dynamic range of a circuit by allowing users to adjust the amplitude of a signal in real time, which is critical for a number of applications involving ultrasound, speech analysis, radar, wireless communications, and instrumentation. We also offer a portfolio of voltage controlled VGAs to provide you with continuous gain control over a wide dynamic range.

  • Dual Channel HV Amplifier with Phase Inverter

    A400DI - FLC Electronics Inc

    This unit contains two independent A400 amplifiers that share common ground reference and power supply. Please see A400 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase. Connecting a load between the outputs effectively doubles the amplitude range. Please note that the load cannot have any connection to ground.