Filter Results By:

Products

Applications

Manufacturers

Frequency Sources

A stable oscillator used for frequency calibration or reference. (atis.org)


Showing results: 226 - 240 of 307 items found.

  • PD Test Systems

    Shanghai Himalayal Co.

    1. Number of channels: 2/4 electric signal interfaces & 1 EXT interface 2. Sampling frequency: maximum 200MGa/s 3. Sampling precision: 12bit 4. Range: 0.1mV~20V 5. Range switch: 1mV, 2mV, 5mV, 10mV, 20mV, 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V 6. Frequency band range: 1Hz-60MHz 7. Range non-linear error: 5% 8. Range of capacitance for test object: 6pF~250µF 9. Power source mode: internal lithium cell / AC 220V 10. Display: 6.5 inches TFT LCD 11. Resolution: 640×480 12. PV: 4GB 13. Hard disk: 32G stiff disk used for storing the test data

  • Power Line Meter

    Alpha Lab, Inc.

    The Line EMI Meter measures electromagnetic interference in a single-phase AC power line. It plugs into a wall outlet (mains socket) and requires no battery. It immediately displays total line noise in millivolts (range 1999 mV, resolution 1 mV) in the frequency range 10 KHz 10 MHz (the frequency limits at which sensitivity is of the maximum sensitivity). A speaker plays the sound of the EMI, amplitude demodulated, in order to identify the EMI source (such as an AM or shortwave radio station vs. a motor vs. an electric arc).

  • 1211a Optical Receiver/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, LLC. has now introduced a new Optical Time Code Receiver, with Auto Switching, a full complement of time code outputs, and Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1211A delivers up to thirty six channels of Time Code outputs, including re-transmission of the optical input. The unit can accept a pair of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity.If the primary input fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • Three Phase AC Voltage Source

    EAC-TAVS - Electronic Test & Power Systems

    The EAC-TAVS is a series of programmable high power AC voltage sources. Each system provides a three phase true sinewave output as standard. Each unit is built in a freestanding cabinet. The output frequency is adjustable in the range of 45 - 105Hz. Different frequency ranges are optional, with up to 805Hz possible. An RS-232 and CAN interface are provided as standard. The high resolution TFT front panel displays a host of measurement and setting functions. Besides standard models, other nominal power levels and voltages can be user specified. Single phase and bidirectional versions are available on request.

  • Materials Test Systems

    Ametek Scientific Instruments

    An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.

  • Signal Generators

    SSG5000X Series - SIGLENT Technologies

    SIGLENT’S SSG5000X series of signal generators can generate analog and vector signals, and have a frequency range of 9 kHz to 4 GHz/6 GHz. They feature the industry-leading performance in phase noise, spectral purity, bandwidth, EVM, output power. The internal IQ modulation generator and waveform playback function make it easy to create even the most complex signal types. They also cover the most important RF band for digital wireless communications and include standard waveform files. The SIGLENT SSG5000X are powerful and cost effective sources that are ideal for R&D, education, and manufacturing.

  • Radiating Loops

    Schwarzbeck Mess Elektronik

    The magnetic, handheld coil was designed to generate defined magnetic field strength in the audio frequency range up to 3 MHz. The main application is immunity testing against magnetic fields according to VG 95377 Part 13 and many others. Depending on the current source characteristics magnetic fields up to 400 A/m can be generated for a short time.There are further rings available on request in order to provide a certain scaling between coil current and magnetic field strength (e.g. 1 Amp coil current = 10 A/m field strength).

  • TimerBlox

    Analog Devices Inc.

    Analog Devices TimerBlox parts are small, accurate, and simple timing devices designed for six basic operations: voltage controlled oscillation (VCO), low frequency clocking, pulse-width modulation (PWM), one-shot generation and signal delay, and power-on reset (POR). TimerBlox devices combine an accurate programmable oscillator with precision circuitry and logic. No capacitors, no crystals, no microcontroller, and no programming are required. A 20 mA source and sink capability enables the devices to directly drive opto-isolators and transformers for electrical isolation. An ideal solution for space-limited applications, each TimerBlox device can be placed at the point of use.

  • Nodal Impedance Analyser

    QT-Hi1 - Qmax Test Technologies Pvt. Ltd.

    QT-Hi1 is an innovative Nodal Impedance Analyzer, which uses the industry’s proven V-I trace techniques of learn and compare of nodal impedances which are represented as VI Curves. It uses innovative Auto Best Curve fit technique an intelligent software alogorithm which enables automatic selection of the best fit value of Voltage, Source Impedance and Frequency of the stimulus waveform. The compact size with re-chargeable battery makes it an ideal companion for on-field applications. The wide 8” touch screen graphical display makes this tool more valuable in test and repair industry at all times.

  • Broadband Mid-Infrared Femtosecond Laser Source

    FemtoFiber dichro midIR - TOPTICA Photonics Inc

    The new FemtoFiber dichro midIR represents an ideal laser source for mid-infrared spectroscopy and imaging. It provides a tunable broadband output in the wavelength range of 5 to 15 m (20 - 60 THz, 670 - 2000 cm-1). The unique 400 cm-1 broad emission spectra allow to excite a wide range of materials at the same time. The air-cooled system is based on TOPTICAs proprietary fiber laser technologies and includes a difference frequency generation (DFG) unit as well as all necessary electronics into the same box. All functions and features are computer controllable by Ethernet or USB interfaces.

  • Rubidium Frequency Standard

    RFS VXI - Holding Informtest

    *RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.

  • Phase & Motor Rotation

    Extech Instruments Corporation

    A Phase Sequence Tester has a 40 to 600-Volt rated range for testing phase orientation of 3-phase power sources over a 15 to 400Hz frequency range. Multiline graphical LCD indicates phase orientation (clockwise or counter-clockwise) and whether each of the phases is live. No battery required. Comes complete with cable, three large color coded alligator clips, and pouch case.

  • Phase Noise Generator / Calibrator

    PNG-A - Noise eXtended Technologies S.A.S.

    The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.