Filter Results By:

Products

Applications

Manufacturers

kV

A thousand volts of electromotive force.


Showing results: 286 - 290 of 290 items found.

  • Surge Tester with Performance Tests

    MEA MSU100 - MOTOMEA

    *MEA MSU100 Series – Fully automatic SURGE testing of 3 phase and single phase stators, armatures, transformers, and motors, ranging from 10 W to 500 kW, and patented Stator/Rotor performance testing.*MEA MSU101 Series – Customized, fully automatic production line testing system with SURGE testing of 3 phase or single phase stators, armatures, transformers, and motors, ranging from 10 W to 500 kW. The system can be also equipped with automatic testing of H.V. and 4-wire resistance, temperature, and patented Stator/Rotor performance testing.*PERFORMANCE TESTING – MEA patented tests – MEA patented performance testing provides fully automatic Stator/Rotor performance tests, showing the UUT performance as it will be after assembled as motor.*Integrated database.*200 V up to 5 kV programmable impulse.*Option for Partial/Low-Energy Discharge.*Go/No Go tests with comparison detection of: Area Size, Diff Zone, Corona Amount, and Corona Number.*Performances tests comparison at cold and hot state (temperature tests via up to 8 thermocouples).*Interfaces: RS-232, USB, Ethernet (for remote control).*Can be controlled via I/O for OEM applications and easy integration for automatic lines.*Special self-calibration function. No need to send back for the vendor's calibration, saving time and costs.*MSU101 integrated and operated with PC having user-friendly Windows 7 interface, with large database for storing test programs and test results.*Barcode reader, individual print-out of test protocols and labels, of H.V. and 4-wire resistance, and temperature measurement can be integrated into the system.

  • 120 A High Voltage 50 Ω Pulse Generator

    TLP-12010C - High Power Pulse Instruments GmbH

    - High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface

  • Fully Automatic Transformer Oil Test Set

    Neutronics Manufacturing Co.

    1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

Get Help