Scanning Probe Microscopes
Used to study the properties of surfaces at the atomic level. (www.eng.yale.edu)
See Also: SPM
-
product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25I35-16
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Spectroscopy Upgrade for Any Microscope
SMS
Get a simple upgrade to your existing microscope, or a turnkey microspectrophotometer system that works out-of-the-box.
-
product
Scanning Electro-chemical Microscope
920D
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
product
Fiber-Optic Probes
Designed with an unparalleled optical quality finish, Optomistic Products has developed a wide array of Fiber-optic Probes to accommodate your specific LED test requirement and mechanical constraints.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Elevated 2.67 (76.00) - 7.00 (198.00) Bead Probe
BTP-72HC-7
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Ultra High 12.90 (366.00) - 48.00 (1361.00) General Purpose Probe
EPA-5E-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Elevated 2.67 (76.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-72T1-7
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Measuring Microscopes, Image Processing
Measuring Microscopes
Optik Elektronik Gerätetechnik GmbH
Image processing software for dimensional measurements, motorized measuring microscopes and fully automatic measuring machines.
-
product
SP200B, 200 MHz, ±60 V, 1X or 10X Attenuation, Single-Ended Passive Oscilloscope Probe
780284-01
The SP200B is a standard switchable passive probe for oscilloscopes that provide 1 MΩ input impedance. Depending on the attenuation ratio, the probe has an analog bandwidth of 6 MHz in the 1x attenuation setting or 200 MHz in the 10x attenuation setting.
-
product
Atomic Force Microscope
LensAFM
The Nanosurf LensAFM is an atomic force microscope that continues where optical microscopes and profilometers reach their resolution limits. It is mounted like a normal objective lens, thus extending the resolution and measuring capabilities of these instruments.
-
product
Area Scan Cameras
JAI provides a wide selection of industrial machine vision cameras with both single-sensor and multi-sensor configurations. Resolutions range from 0.3 MP to 20 MP, with high frame rates ranging up to 250 fps for full 5MP resolution. A selection of cameras can operate beyond the visible – in the ultraviolet, near infrared and in the short wave infrared light spectrums.
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3F-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74T80-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1T1-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
G-S General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
Scanning Electrochemical Systems
The VersaSCAN is a single platform capable of providing spatial resolution to both electrochemical and materials-based measurements. Each VersaSCAN is based on a common high-resolution, long-travel, closed-loop positioning system mounted to a vibration-resistant optical base. Different auxiliary pieces are mounted to the positioning system. These ancillary pieces (e.g., an electrometer, piezo vibration unit, or a laser sensor) provide functionality to the positioning system for different scanning probe experiments. VersaSTAT potentiostats and Signal Recovery Lock-in Amplifiers are integrated via ethernet control to make accurate measurements of these small signals.
-
product
Horizontal Digital Microscope
BVM-20107
The microscope is configured with 1.3M HD industrial camera. VGA image output interface, can be connected to the computer and monitor directly. clear and vivid image, image freeze, auto exposure, dual cross lines , 8 mobile cross lines, color is variable, convenient observation and positioning. Camera is equipped with remote control panel, which makes the operation much easier
-
product
Fiber Optic Inspection Microscope
80761
The Miller 400x Microscope helps inspect fiber optic connectors quickly and easily. Its ergonomic design and built-in features make it ideal for field and lab use. The microscope features a pressure-activated on/off switch, focusing wheel, eyepiece, auxiliary white LED light source rated for 100,000 hours, adapter tip for inserting ferrule and battery compartment. Includes 2.5mm universal adapter cap and zipper case.
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1A-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Scanning Probe Workstations
BioLogic has over 25 years of experience producing scanning probe electrochemistry instruments. Initially this included a number of single technique instruments, with the first modular scanning electrochemical workstation, the M370, introduced in 2006, under the Uniscan name.Scanning probe electrochemistry has found use in academic and commercial research settings. It is applicable in any field in which bulk electrochemical measurements have been used. Scanning probe electrochemistry has found widespread use in: Corrosion and coatings, Biology, including biosensors and biotechnology, Batteries, fuel cells and photovoltaics, Materials, Catalysis
-
product
Stereo Microscopes & Macroscopes
Leica Microsystems offers customized stereo microscopes for research, industry and education. Our macroscopes for industry, medicine and research offer exceptional optics and ultra convenient operation. Stereo microscopes and macroscopes from Leica enable you to view, analyze and document your specimens in two and three dimensions for any application.
-
product
Ultra High 12.90 (366.00) - 48.00 (1361.00) General Purpose Probe
EPA-5H-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
BIP-3 Battery Probes
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1Z1-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72I15-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-2W1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1W2S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Industrial CT Scanning Services
Computed tomography (CT) is also referred to as industrial x ray and industrial imaging. It is an x-ray methodology yielding 3-dimensional (3D) results by placing an object on a rotational stage between an x-ray tube and x ray detector, rotating the object 360 degrees and capturing images at specific intervals—such as every degree or every half degree.
-
product
Alternate 2.54 (72.00) - 6.20 (176.00) General Purpose Probe
HPA-52B-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98