Filter Results By:

Products

Applications

Manufacturers

Liquid Level

the height a liquid in relation to it's container.

See Also: Level, Signal Level Meters, Level Transmitters, Liquid


Showing results: 151 - 152 of 152 items found.

  • General Purpose Radiation Survey Meter/Geiger Counter

    Rad 100™ - International Medcom

    The RAD 100™ is a general purpose radiation survey meter/geiger counter that detects and measures alpha, beta, gamma, and X-radiation. It is intended for personal safety and educational purposes. Like the popular Radalert® 100X, the RAD 100™ features a 3-second update on its digital liquid crystal display (LCD). The LCD shows the current radiation level in your choice of microSieverts per hour (SI units) or mR/hr for gamma radiation measurements. For mixed sources (alpha, beta, gamma) the CPM mode is recommended. This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours. A red LED blinks and a beeper chirps with each count (the chirp can be muted). This is a professional instrument that is also easy to learn to use and to operate, and carries the industry leading Medcom warranty (2 years overall limited to 1 year on the GM sensor). Many instruments designed by the Medcom team are still working perfectly after 30 years of use, so this instrument should provide a lifetime of useful information.

  • Oil Tan Delta Tester

    OTD - Megger Group Ltd.

    The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.

Get Help