RCD
Residual Current Device
-
Product
RCD Loop Line
-
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
Product
230V AC Socket Tester With RCD Test (For UK)
1944
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*RCD Test.*30mA leakage current measurement.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon idnicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1.5W*Frequency: 50Hz
-
Product
Resistive & Capacitive AC Load Bank
RCD
-
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
-
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
Product
CombiVolt™ 1 Voltage/Continuity Tester
DL6780
-
Testing of AC/ DC voltages from 12 to 690 V AC/DC Continuity testing with optical and acoustic indication Automatic switching between voltage and continuity Phase rotation test system Single pole phase indication Fully compliant with GS38 Fully operational voltage indication even when batteries are discharged Will not trip any RCD when testing across Live and Earth Single pole detection when L2 probe connected above 100V
-
Product
Installation Tester
M74
-
M74 measures Overall earth resistance, tripping time of RCDs type AC, Insulation and Continuity of earth and equipotential conductors according to the laws in force in private electric installations.
-
Product
RCD Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.
-
Product
Voltage & Continuity Testers
-
Our range of CombiVolt voltage testers are designed to measure AC/DC voltages and continuity. Most models provide LED indication, an audible tone or a combination of both while others have a digital display to give an exact reading, all testers have a non RCD Trip feature
-
Product
Digital RCD Tester
1612 EL
-
Standard Electric Works Co., Ltd
●Microprocessor-controlled●Extra large LCD (78 × 67mm)●Very low power consumption●50Hz and 60Hz operation●Accurate digital readout of disconnection time●Over temperature protection●Over voltage protection●Fuse protection●Zero crossing circuitry permits testing at 0° or 180°●Auto power off●Backlight function●Wiring polarity indicator●Measures voltage between Line and Earth before testing●Frequency measurement indication
-
Product
Multifunction Electrical Installations Meter
MPI-525
-
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
Product
Socket Tester
1945
-
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
Product
Recorder Carrier Device
RCD
-
The RCD is a carrier signal demodulator for SCADA and Fault Data Recording. the RCD demodulates the carrier to indicate the presence of a relative level of a singal
-
Product
Multifunctional testers
MI 3102 BT EurotestXE
-
MI 3102 BT EurotestXE is a multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. It supports AUTO SEQUENCE® testing of the TN, TT and IT earthing systems. ISFL measurements and the IMD tests can be performed. Besides, the MI 3102 BT EurotestXE enables on-line voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement and TRMS current measurement. EurotestXE is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
Product
Digital ELCB (RCD) Tester
1811 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).
-
Product
Multifunction Installation Tester
COMBI519
-
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Multifunction Electrical Installations Meter
MPI-520S
-
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
Product
Digital ELCB (RCD) Tester
1812 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto-off and off override.● Polarity Trip indicator (Positive of Negative Phase).● Wiring polarity indicator.● Measure voltage and frequency between Line and Earth before testing.
-
Product
Multifunction Tester
COMBI521
-
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Multifunctional testers
MI 3100 SE EurotestEASI
-
MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
Product
EV Test Equipment
-
Di-LOG’s New EV Test Equipment Range which includes the DL9100 series MFT incorporates the DL9120 and DL9130EV with both products boasting DC capability, paving the way for a host of tests-specific to the *EV and PV sectors, mainly the ability to conduct a Type B (Pure DC) RCD test.
-
Product
Multifunction Tester
EASYTEST
-
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Electrical Test Equipment Calibrators
-
The industry leading series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers.
-
Product
Short Circuit Loop Impedance Meter
AMZC-304
-
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Product
Multifunction Instrument
COMBI521EV
-
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
SMD Testers
-
Is a miniaturized and integrated utility model measuring instrument, which can automatically identify components such as resistance, capacitance, diode, etc., with LED, voltage regulator, DCV, on-off and battery power measurement functions. SMD resistance, capacitance, diode (RCD) parameter measurement, is a good helper for electronics factories and electronics maintenance.
-
Product
Digital RCD Testers
-
Used to detect whether the RCD in the circuit can be triggered normally.
-
Product
Digital RCD/RCCB/GFC/ELCB Tester
4112 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.
-
Product
Multifunction Installation Testers
-
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
Product
Socket Outlet Tester
-
Using the new Testavit Schuki 1 LCD and 3 LCD, specialists easily check to see if sockets, cable drums or connecting cables are correctly connected in 230 V installations. Due to three LEDs, the connection status can be quickly and clearly determined. In addition, through the finger contact, it can be tested to see whether an impermissible, high contact voltage is applied at the protective earth connection. In addition, using the Testavit Schuki 1 LCD, a 30 mA FI circuit breaker (RCD) can be triggered via a pushbutton.
-
Product
Socket Tester with RCD Tripping
-
Shanghai Beha Electronics Co., Ltd.
*Mains wiring polarity check.*ELCB/RCD testing.*Measuring ear for line current.*Measuring ear for leakage current.*Helps calculate insulation resistance.*Helps calculate power consumption.*Helps fault finding of standing earth fault.*Fused main adapter.*Appliance testing (with the ad of a clamp meter).