Current Comparators
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-33
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size*AC 1A~200A*Current measurements of feeder
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-40
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size*AC 1A~600A*Current measurements of feeder
-
Product
High Current Probe HC200B06G71
1033974
-
The HC200B06G71 High Current Probes are designed for optimal performance in high-temperature environments, capable of operating between -45°C and +200°C. This specific model is engineered for electrical applications requiring significant currents, with a continuous capacity of 300A and a remarkable typical contact resistance of just 0.20 mOhm. These probes are constructed from premium materials, featuring a beryllium copper tip style that is plated with gold for enhanced conductivity and durability.
-
Product
AC/DC Leakage Current Tester
228
-
Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.
-
Product
High Current Probe HCF34017A300U400
1005479
-
The HCF34017A300U400 high current probe is specifically designed for battery contacting applications, offering exceptional performance in diverse environments. Rated for a continuous current of up to 16A, this probe is engineered to operate effectively within a temperature range of -45°C to +200°C. Its robust design ensures low typical contact resistance of just 10 mOhm, making it an ideal choice for high-efficiency electrical applications.
-
Product
Current Meter
Model 106
-
The Model 106 is the ideal instrument for coastal and estuarine applications and other light-duty survey work.
-
Product
Current Dataloggers
-
With our selection of current data loggers, you can meet requirements that include the single/split phase, three-phase, neutral, ground current and machine load monitoring. You can also utilize our current loggers for fault current detection, leak identification, and load profiling. We have compact models constructed to be weatherproof. Choose from stand-alone, handheld and clamp-on configurations. Our current data loggers are used in a broad scope of applications, trusted by technicians, electricians and engineers.
-
Product
High Current Probe HCF72306B350G150
1132082
-
The High Current Probe HCF72306B350G150 (item number 1132082) is designed for safe transmission of high electrical currents in test and contacting applications. HCF72306B350G150 focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. For HCF72306B350G150, contact resistance, contact force and thermal behavior must be considered together because they influence voltage drop and temperature rise at the contact point. The intended application area for HCF72306B350G150 includes power-electronics testing. HCF72306B350G150 is rated for 30 A continuous current with a typical contact resistance of 8 mΩ. For HCF72306B350G150, spring force is 150 cN at a nominal travel of 2.8 mm.
-
Product
Current Preamplifier
1641
-
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Current Transformer Test Set
-
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
Product
Eddy Current Testing Instruments
INSITE HT & CT
-
The Zetec InSite HT and InSite CT are multi-channel, multi-frequency eddy current testing instruments. They are both designed to operate at full production line speeds in tough manufacturing environments. Both the InSite HT and InSite CT are available in 2, 4, and 8 channel versions.
-
Product
Testing of Current Measuring Transformers
-
All components from this category can be integrated into an existing current transformer test system. When selecting CT test components, both the type of converter to be tested and the required current are important.
-
Product
Pressure Comparator (System F)
Type T
-
AMETEK Sensors, Test & Calibration
Type T hydraulic comparator (System F) is a self-contained high volume pressure source capable of producing pressure up to 15 000 psi. It is ideal for testing gauges and setting hydraulic relief valves and pressure switches. Multiple models are available for hydraulic oil, water, or both.
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
T3CP Series AC/DC Current Probes
T3CP Series
-
Teledyne Test Tools AC/DC Current Probes are powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range of five current probes includes models with bandwidths up to 100 MHz, peak currents up to 500A and sensitivities to 1 mA/div.
-
Product
Process / Voltage / Current
-
Calibrator high precision process signals able to measure and generate current and voltage.
-
Product
High Current Probe HC060A06G5
1014587
-
The High Current Probe HCF35006B600G530 (item number 1014587) is designed for safe transmission of high electrical currents in test and contacting applications. HCF35006B600G530 focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. For HCF35006B600G530, contact resistance, contact force and thermal behavior must be considered together because they influence voltage drop and temperature rise at the contact point. The intended application area for HCF35006B600G530 includes battery and power-electronics testing. The probe is rated for 50 A continuous current with a typical contact resistance of 6 mΩ. Spring force is 530 cN at a nominal travel of 5 mm.
-
Product
Split type AC Current Transformer
CTS-200
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-01
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
Low Noise Current Preamplifier
SR570
-
Stanford Research Systems, Inc.
The SR570 is a low-noise current preamplifier capable of current gains as large as 1 pA/V. High gain and bandwidth, low noise, and many convenient features make the SR570 ideal for a variety of photonic, low temperature and other measurements.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-600B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
High Current Probe HCF73512A300U1000
1044962
-
The HCF73512A300U1000 is a high-performance Basic Contact Probe designed to cater to applications requiring high current handling capabilities. With a continuous current rating of 50A, this probe ensures reliable electrical connectivity even under extreme conditions, making it ideal for battery contacting in various electronic devices. Its operational temperature range spans from -45°C to +200°C, providing versatility and functionality in diverse environments.
-
Product
Current Logger0 to 25mA DC
TV-4804
-
The TV-4804 measures current from 0 to 25mA DC and can be connected to a variety of industry standard sensors enabling the logging of a wide range of process parameters.
-
Product
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)
ZCT-150T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy installation.*For leakage current measurements of bus bar*Unique split and track type ZCT sensor*High sensitive and least affection from external magnetic field
-
Product
Device Current Waveform Analyzers
-
The dedicated Current Sensors measure from 100 pA level dynamic current up to 10 A with a maximum of 200 MHz bandwidth. The mainframe acquires the signal from the sensors by a maximum of 1 GSa/s sampling speed and 14-bit and 16-bit wide dynamic range. This combination allows you to measure quite wide range of dynamic current, for example, from standby/sleep state to active state, at a single measurement. In addition, the wide bandwidth and the high speed acquisition enable you to measure high speed pulse response even less than 100 ns previously very difficult with existing instruments.
-
Product
500A AC/DC Current Sensor
CT6904
-
Hioki pull-through AC/DC current sensors are best-in-class devices for use with power analyzers,, Memory HiCorders and high performance oscilloscopes. The CT6904 is a DC to 4 MHz/500A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.
-
Product
Flexible AC/DC Current Tester
FCM-400
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Bending free flexible clamp sensor*Measuring ranges AC/DC 0.100A~300A(Min. resolution 0.001A)*Big CT window (φ450mm)*Easy accessibility to the hard to clamp object
-
Product
High Current Probe HCF73212A200U300A
1165609
-
The HCF73212A200U300A High Current Probe is designed for precise and reliable battery contacting applications. This robust probe boasts a wide operating temperature range of -45°C to +200°C, making it suitable for various environments and conditions. With a continuous current capacity of 20A and a minimal contact resistance of only 10 mOhm, this probe ensures optimal performance for high-current testing applications. The design incorporates user-friendly features such as a nominal travel of 4mm and a maximum travel of 5mm, ensuring precise measurements with a pointing accuracy of +/- 0.08mm.