Showing results: 1 - 15 of 52 items found.
-
CDF 6000 -
UDEYRAJ ELECTRICALS PRIVATE LIMITED
CDF-6000 is fully automatic: It automatically ramps up to set test voltage, makes measurement, ramps down test voltage to zero and prints out test results.
-
TD Series -
b2 High Voltage
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
HTJS-V / 270 -
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement high-precision instrument of dielectric loss tangent value and capacitance of high-voltage power equipment of power plant, substation and other scene automatic measurement.
-
Weshine Electric Manufacturing Co., Ltd
The Oil Tan Delta Tester (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. WESHINE has developed features of the OTD to ensure that productivity levels within laboratories are maximised.
-
PDIX Series -
High Voltage Inc.
PDIX is a combined partial discharge and tan delta cable diagnostic testing system. By combining HVI’s VLF products with PDIX products, users can perform VLF AC withstand, partial discharge detection, and tan delta measurement on medium and high voltage cables, rotating machinery, and other apparatus with one integrated package fully supported by HVI & PDIX.
-
Shanghai Jiuzhi Electric Co., Ltd.
Nearly every high voltage equipment prior to delivery to the customer will undergo a test related to capacitance and tan delta for a final quality control. Such tests are in general made at a frequency for which the equipment is designed. The reasons for the tests are firstly that too high losses ( means high tan delta) may cause a breakdown, secondly, the manufacturer of a specific equipment knows the typical magnitudes which can be tolerated and which provide information about the quality of newly manufactured equipment, and these measurements can also serve for a comparison with later preventive measurements.
-
TD 5000 -
Altanova Group
The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range.
-
Bushing Tap Adapter Kit -
Altanova Group
Bushing Tap Adapter Kit is designed to perform Capacitance and Tan Delta tests on power transformer bushings The kit can b e used with the following ISA Test Set STS 5000 TD 5000 STS 4000 TD 5000 TDX 5000.
-
Shanghai Himalayal Co.
Diagnostic test that indicates the degree of cable insulation degradation. Rather than using only a VLF instrument to perform a go/no-go proof test, the Tan Delta, used in conjunction with a VLF hipot, permits the user to grade the deterioration level of many cables in order to prioritize replacement, rejuvenation, or to determine what additional tests may be useful.
-
OTD -
Megger Group Ltd.
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.
-
Himalayal Corporation Limited
Precision measuring bridge is designed for determining the capacitance and dielectric dissipation factor of liquid and solid insulants, cables, capacitors, line transformers, generators, motors, bushings etc. Furthermore it can also be used for power loss measurement on shunt reactors or similar apparatus. This system is suitable for both low and high voltage measurement at line frequency. Measurement reports can be printed. This measuring equipment has been specially developed to maximise efficiency in production and quality control environments. Its outstanding accuracy also makes it suitable for laboratory and research applications.
-
-
Neutronics Manufacturing Co.
*DIGITAL DISPLAY for Capacitance and Tan Delta*NO NEED of calculation*SAVING OF Result and INTERACTIVE DOWNLOAD*SOFTWARE*High Resolution for Tan Delta -5 0.00001 (10 ) measurements*Easy to use*Safety Protections incorporated
-
Megger Group Ltd.
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
TDX 5000 -
Altanova Group
TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines.