Loop Calibrators
Simulate, power and measure closed circuit signals.
-
Product
Aircraft and Truck Scale Calibrator
-
Morehouse Instrument Company Inc.
Aircraft and truck scale calibration often requires special adapters to simulate a tire. Scales come in a variety of sizes and have specific tolerances. Many other calibration laboratories do not use the right adapters or consider the impact of the uncertainty of the reference standard used for calibration.
-
Product
Torque Calibration
-
Trescal provides full Torque Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Torque Calibration services can be delivered at your site or at our lab. Accreditations for our torque calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Electrical Calibration
-
All calibrations include as Found/as Left data, Measurement Uncertainity, Calibration Sticker, Calibration Certificate and online access to calibration data at NO additional charge.
-
Product
Vibration Transducers Calibration System
-
The system is used for calibration of vibration transducers as well as:*ICP and charge accelerometers;*piezoelectrical and capacitive vibration transducers;*vibration-measuring instruments.
-
Product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
-
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Calibrators
-
Ensure the accuracy and reliability of your leak and flow testing instruments with our cutting-edge calibrator. Specifically designed for precision calibration, our product stands out in the market for its innovative technology and user-friendly features. Ideal for a wide range of industries, this calibrator is essential for maintaining the integrity of your leak and flow testing equipment. With its robust design and exceptional accuracy, our calibrator is a must-have for professionals seeking to uphold the highest standards in leak and flow measurement. Whether you’re in manufacturing, engineering, or quality control, our calibrator is the perfect tool to ensure your instruments are performing at their best. Discover the difference in precision and reliability with our top-tier calibrator for leak and flow testing instruments.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
-
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
IDevice Calibrated Measurement Microphone
IMM-6
-
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
Product
Dual Loop Master Controller
-
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)
CK058M
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Multiport Calibrated Measurements With Switch Instruments
S97553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments
-
Product
Current & Voltage Sources for Calibration of Measuring Systems and Sensors
-
ChenYang Technologies GmbH & Co. KG
*DC/AC Current: 0-60A *DC/AC voltage: 0-1000V frequency 50Hz, 60Hz, 400Hz, 1kHz
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)
CK058F
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)
CK562A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
- RS-232 to Current Loop Converter
Model 65A
-
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
Product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
-
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
Product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
-
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
MTB Calibration Adapter
2450-CAL-30
-
The MTB Calibration Adapter (Catalog No. 2450-CAL-30)is a socket adapter that’s designed to bring phase A, B, and C current and potentials of a TESCO Multi-Position Test Board to an external RD-30 reference standard for calibration of the Test Board.
-
Product
NIST Calibration for D420-A
D420-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
-
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Time to Amplitude Converters and Calibrator
-
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
Product
Calibration Sources
-
Accurately verify the output signals of your pyrometers, thermal imaging systems, heat-flux measurement systems, or spectrographic analysis systems. We offer unique and very precise Mikron® calibration sources. Our blackbodies feature cutting-edge emissivity values, homogenous emission areas, and various different-sized apertures. And fast heat-up times and high temperature stability are guaranteed.
-
Product
Multi-function Desktop Calibrator
VA730
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function Desktop calibrator DC Voltage/Current Source.
-
Product
Loop and Line Powered Level Switch
Safety IntelliPoint
-
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
On-Site Calibration Services
-
Labsphere offers on-site spectral radiance calibration services for HELIOS and other uniform source systems.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 8 Channel
43-765-003
-
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Single Loop Controller
1160+
-
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.