Loop Calibrators
Simulate, power and measure closed circuit signals.
-
Product
Dual Loop Master Controller
-
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
Product
Friction Flow Loop System
-
Friction Flow Loop System is used for testing the effects of friction reducers by circulating at high rates through different pipe diameters. Friction Loop designs vary based on the application required.
-
Product
VNA Calibration Kits
-
Standard calibration kits used for manual network analyzer calibration
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
Pressure Calibrator
HPC50
-
AMETEK Sensors, Test & Calibration
The HPC50 handheld pressure calibrator is an intrinsically safe, dual pressure calibrator with options to add an additional two external pressure or temperature modules. The HPC50 pressure calibrator combines the features you love from the HPC40 with improvements like, better battery life an improved display, an extra external module connection, and of course intrinsic safety.
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
Test Equipment Calibration
-
EMC Technologies can provide convenient, local, NATA accredited calibration services which greatly reduces lead time and costs for EMC test equipment. In the past these items had to be sent overseas or to expensive government laboratories. We can calibrate these items against common standards such as CISPR 16 (and subparts), IEC 61000-6-X series, ANSI C63.4, ANSI C63.5 and ARP 958.
-
Product
Calibration Segment Arm
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Segment arm is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Calibration And Certification
-
We also offer a wide range of Tools and Calibration Artifacts for Portable Coordinate Measuring Arms and Laser Trackers. Some of these artifacts we can also supply Certified with a NIST Traceable certificate. We also supply accessories including batteries, cables and other Misc tools.
-
Product
Spectral Irradiance / Illuminance Calibration Standards
-
Standard lamps calibrated in illuminance and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Calibration Kit
S2611
-
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.
-
Product
Multiport Calibrated Measurements With Switch Instruments
S95553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments such as the M9164A/B or M9165A/B PXI Solid-state Switch Matrix. The software includes an easy-to-use measurement wizard that simplifies measurement procedures and reduces the setup time of complicated multiport measurements. The VNA displays measured multiport S-parameters.With the combination of M980xA PXIe VNAs and M916xA/B switch matrix, up to 66 ports (2 VNAs (4 ports and 6 ports M980xA), plus 4 modules of 2x16 M9164A/B) can be configured and supported. Measurement specification is supported when using the M9164B/M9165B 9 GHz switch modules.
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
Power Calibrators And Power Quality Calibrators
-
Calmet Smart Calibration Devices
A power calibrator and a power quality calibrator are both specialized instruments used to verify and adjust the accuracy of other instruments, but they focus on different aspects of electrical power.
-
Product
Calibration Services
-
Edgetech Instruments Inc. has the ability to calibrate any hygrometer (Edgetech Instruments or other manufacturers)Edgetech Instruments performs NIST traceable calibrations and is compliant with ANSI/NCSL Z540-1 and ISO 9001Calibration capabilities include 0-95%RH, dew points down to -75C, traces of oxygen to 10ppm
-
Product
Partial Discharge Measurement Calibrator
DAC-CP-2
-
DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
Product
Calibration & Testing Unit for AC & DC Meters
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Product
Temperature Calibrators
-
We offer temperature calibrators in different shapes. We offer temperature dry blocks that can generate an accurate temperature, for example for temperature sensor calibration. We also offer electrical temperature calibrators that can measure and simulate various temperature sensors (RTDs and thermocouples). We also offer high-accuracy reference temperature probes.
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
-
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
-
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
Product
Lens Calibration
SpyderLENSCAL
-
A fast, reliable method of measuring and adjusting the focus performance on your camera and lens combinations.
-
Product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
-
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Product
Pressure Calibration
-
Trescal provides full Pressure Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Pressure Calibration services can be delivered at your site or at our lab. Accreditations for our pressure calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Handheld Economic Process Calibrator
VA701
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.





























