Voltage Sensors
See Also: Voltage Transducers, Current Sensors, Voltage Calibrators
-
product
AC Voltage Monitors
NAI's AC- and DC-powered AC voltage monitors are used to monitor and measure voltage characteristics of single- and three-phase power lines. Field-adjustable AC voltage monitors are also available. These monitors are specifically designed for rugged defense and industrial applications.
-
product
sbRIO-9264, Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
781119-01
Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The sbRIO‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the sbRIO‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection. Non-enclosed modules are designed for OEM applications.
-
product
NI-9209 , ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
785042-01
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
product
E-Series Peak and Average Power Sensor, 50 MHz to 6 GHz
E9321A
The E9321A power sensor has a 300 kHz video bandwidth and is ideal for time-gated peak, average and peak-to-average ratio power measurements on TDMA wireless formats such as NADC, GSM and EDGE.
-
product
10 MHz To 54 GHz LAN Wide Dynamic Range Average Power Sensor
L2056XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
E-Series Peak and Average Power Sensor, 50 MHz to 6 GHz
E9322A
The E9322A power sensor has a 1.5 MHz video bandwidth and is ideal for time-gated peak, average and peak-to-average ratio power measurements on TDMA and CDMA wireless formats such as Bluetooth.
-
product
POF Ext Ø 1,5mm 600mm, from Light Probe to VPC ITA Contact (R)
YAV90CLR11
600mm Length. 1,5mm External diameter.
-
product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
779011-01
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
product
NI-9222 , ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781397-01
±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
product
NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
780173-01
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
product
10 MHz To 67 GHz LAN Wide Dynamic Range Average Power Sensor
L2057XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
780927-02
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.
-
product
Thermocouple Power Sensors
N8481H
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
product
10 MHz to 18 GHz USB Wide Dynamic Range Average & Peak Power Sensor
U2062XA
The Keysight U2062XA is a fast, accurate and wide dynamic range 10 MHz – 18 GHz USB peak power sensor.
-
product
NI-9252, ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module
786783-01
±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module - The NI-9252 is an 8-channel analog input module for CompactDAQ and CompactRIO systems. Each channel provides a ±10 V measurement range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9252 features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
783732-01
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
product
REM-11100, 2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O
784748-01
2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O - The REM‑11100 is a voltage input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11100 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. This module features 2‑, 3‑, and 4‑wire spring terminal connection methods, a built-in power supply for sensors, four selectable input ranges, and simultaneous sampling.
-
product
E-Series Average Power Sensor
E9301B
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formats Low SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
FD-11605, 8-Channel, ±60 V Voltage Input Device for FieldDAQ
786469-01
The FD-11605 can measure up to eight channels with a voltage input range of ±60 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11605 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages of up to 1000 V. The FD-11605 has an ingress protection rating of IP65/IP67 (dust-tight and water-resistant),can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11605 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11605 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11605 is ideal for test cell and outdoor environments.
-
product
S2 Spectra Sensors
ULP-S2 WBI/V
The ULP S2 Spectra Sensor tests for LED intensity, and for any color in the visual spectrum, plus white. The S2 Spectra Sensor is well-suited for the test of “boundary” color LEDs, as it can unambiguously and repeatedly distinguish between not only adjacent visual colors such as green and yellow, but it can determine different hues of the same color such as yellow and amber, regardless of LED intensity. Implemented in a unique and customizable 2-Part solution, the S2 Spectra Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Output Loads: ‘Int.’& ‘Color’- 2Kohms min., 100pF max.Sensor Size: 0.560 in. dia x 1.38 in. long.Typical response time: Typical response time: <10mS capture time; <100mS overall response timefor color and intensity simultaneouslyFiber-Optic Probes: Can be paired with any Universal LightProbe Fiber-Optic Probe
-
product
NI-9209, ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
783729-01
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
product
S2 Blinx Digital Sensors
ULP-S2 BLINX
The Universal LightProbe S2 Blinx Digital is designed for the simple ON/OFF test of any color blinking or steady-state LED, for fast results with a digital output. The Universal LightProbe S2 Blinx Digital Sensors check the ON/OFF status of any color LED, whether stable or blinking/pulsed, up to a rate of 15 Hz, and provide a Logic “1” output (5 volts) only if the LED is “ON” and a Logic “0” if the LED is “OFF.”Operating temperature range: 0oC to 70oCPower consumption: Operates from +5, 12, 24 or 28 volts D.C., at 6mA max.Voltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Load: 20mA max. (Source/Sink). Non-inductiveOutput Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longOperating Temperature Range: 0hC to 70hCTypical response times: <66mS, shorter for brighter LEDsFiber-Optic Probes: Wide Aperture Fiber-Optic Probe recomended
-
product
sbRIO-9220, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
787814-01
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The sbRIO‑9220 helps you perform differential analog input. The sbRIO‑9220 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and … noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
NI-9202, ±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module
784400-02
±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module - The NI-9202 has excellent flexibility to meet the needs of your applications. The module has 16 simultaneous sampling, differential input channels to create large, distributed systems in a rugged form factor. It … also has configurable filters to eliminate noise in your system while maintaining low-latency to be used in control systems.
-
product
3U OpenVPX Sensor Interface Unit
SIU32S
The SIU32S is a highly configurable Modular Open Systems Approach (MOSA) rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, processing, communications and Ethernet switching. The SIU32S leverages NAI’s Configurable Open Systems Architecture™ (COSA®) 3U boards and smart function modules to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
product
Wide Dynamic Range Power Sensor, E-Series
E4412A
Fast measurement speed, up to 400 readings per second with the E4416AWide dynamic range (-70 dBm to +20 dBm)Calibration factors, linearity ana temperature compensations data stored in EEPROM Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to NIST Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
sbRIO-9221, Non-Enclosed, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781116-01
Non-Enclosed, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the sbRIO‑9221: a 36‑position spring‑terminal connector and a 37‑position DSUB connector. Non-enclosed modules are designed for OEM applications.
-
product
Thermocouple Power Sensors
N8487A
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
product
AC-Powered, AC Voltage Monitor, Adjustable
VMA
NAI’s VMA is a field-adjustable, AC-Powered, AC Voltage Monitor used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits.High and low voltage limits, and "pick-up" and "drop-out" time delay are field-adjustable. The VMA voltage monitor is ideally suited for rugged defense and industrial applications.
-
product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
780927-01
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.





























